My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1999 PIPING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3011
>
2300 - Underground Storage Tank Program
>
PR0231883
>
REMOVAL_1999 PIPING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:52 AM
Creation date
11/5/2018 11:59:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1999 PIPING
RECORD_ID
PR0231883
PE
2351
FACILITY_ID
FA0002111
FACILITY_NAME
BEN HOLT SHELL
STREET_NUMBER
3011
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10018010
CURRENT_STATUS
02
SITE_LOCATION
3011 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BENJAMIN HOLT\3011\PR0231883\PIPING REMOVAL 1999.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.,NO <br />SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If <br />contamination is documented during closure, an Unauthorized Release Notification must be completed and submitted within five (5) <br />working days pursuant to California Health & Safety Code, Section 25295. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />Sample eyea 20 lineal feet <br />< 1,000 <br />1 per Tank <br />Fill OR Pump End of Tank <br />2 <br />1,000 - 10,000 <br />2 per Tank <br />1 at each End of Tank <br />1 1 2 <br />l� <br />> 10,000 <br />3 or More <br />per Tank <br />Ends and Middle OR generally <br />spaced along the length of the Tank <br />-PNNWY AR& V;(b-n1Q TD ReMPON - <br />PIPING AND STOCKPILE <br />1 <br />Z <br />PIPING SOIL SAMPLES <br />1 <br />Sample eyea 20 lineal feet <br />< 1,000 <br />Z <br />TANK & PIPING STOCKPILE SAMPLES <br />2 <br />Samples every 50 cubic yards <br />WATER IS PRESENT IN TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL <br />SAMPLES <br />MINIMUM NUMBER <br />of WATER SAMPLES <br />< 1,000 <br />< 10,000 <br />Center and Ends OR Sides of Tank <br />2 from wall next to tank <br />1,000 - 10,000 <br />/ <br />Single Tank <br />3 <br />ends at soil/groundwater <br />I <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />interface & I below tank <br />4 from wall next to tank <br />> 10,000 OR <br />ends at soil/groundwater <br />j1 <br />Tank Cluster <br />5 or more <br />interface & 1 below each <br />I <br />tank <br />TAnIj�,s age IRX(srtTNCr Ta ReMAIW- <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />< 1,000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />F14 <br />1,000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />-13%KS AftliE "t MNEc TO PMMAiM, <br />EH 23 046 (Revised 08/13/99) Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.