My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BONHAM
>
4950
>
2300 - Underground Storage Tank Program
>
PR0232528
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2024 3:37:07 PM
Creation date
11/5/2018 12:12:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232528
PE
2381
FACILITY_ID
FA0003951
FACILITY_NAME
LINDEN MEDICAL CENTER INC
STREET_NUMBER
4950
Direction
N
STREET_NAME
BONHAM
STREET_TYPE
ST
City
LINDEN
Zip
95236
APN
09126009
CURRENT_STATUS
02
SITE_LOCATION
4950 N BONHAM ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BONHAM\4950\PR0232528\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
1/19/2012 8:00:00 AM
QuestysRecordID
110276
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> STATE OF CALIFORNIASTATE WATER RESOURCES CONTROL BOARDUNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM BCOMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT F7 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE REM ❑ 2 INTERIM PERMIT F-1 4 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE ❑ B TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNERS TANK I.D.# y B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) v D. TANK CAPACITY IN GALLONS: <br /> II.TANKCONTENTS IFA-11SMARKED.ODMPLETEREMC. <br /> to REGULAR 3 DIESEL <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C• ❑ UNLEADED ❑ S AVIATION 6A3 <br /> ❑ 2 PETROLEUM ❑ 90 EMPTY ❑ 1 PRODUCT ❑ Ib PREMIUM 4 OASAFIOL E:] 7 METHANOL <br /> UNLEADED 5 JETFUEL <br /> ❑ 3 CHEMK:ALPRODUCT �5 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.f: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOXO <br /> A. TYPE OF ❑ I DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER 5 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> S. TANK ❑ I BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDE MINUM F-18 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tmk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL UPNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LNNG ❑ 3 EgLINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR F-15 GLASS LINING ❑ 8 UNLINEDI.r65/UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 NYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A(tl!> OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH U UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U S CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WARP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODICPROTECTK)N UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ I AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 MO0ITNRORING OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION E] 3 V R MONITORING C] d AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> E] e TANK TESTING ❑ 7 INTERSTITIAL MONITORING 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAV/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> 1PRNMD&S WREI <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION4, FACILITY 7 7TANK <br /> STATE I.D.# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> FORM 8 (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FOROWIBR4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.