Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
STATE OF CALIFORNIA "ts °°i <br /> / STATE WATER RESOURCES CONTROL BOARD i - <br /> I UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B W�� H <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM " / <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE �8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> -5,-z 9 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.0 L B. MANUFACTURED BY: y„ <br /> C. DATE INSTALLED(MO/DAYIYEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK CO_NTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> 7 MOTOR VEHICLE FUEL 4 OIL e_ C 1a REGULAR DIESEL <br /> A. O ❑ UNLEADED ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM 4 GASAHOL ❑ 7 METHANOL <br /> UNLEADED ❑ 5 JET FUEL <br /> O 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> 0. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.o: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.R.AND C,ANDALLTHAT APPLIES IN BOX DANDE <br /> A. TYPE OF ❑ 11�DOUBLE WALL O 3 SINGLE WALL WITH EXTERIOR LINER O 95 UNKNOWN <br /> SYSTEM E2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE O 6 POLYVINYL CHLORIDE O 7 ALUMINUM O 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTARk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL O 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING ❑ 6 UNLINED �l LNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 V L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION F-15 CATHODIC PROTECTION F-191 NONE 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILLAND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE AV SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL Wt COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION <OIS UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ MONRORINGTITW ❑ OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZEMONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE5 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO <br /> 7-�- 7- 57-1- SUBSTANCE REMAINING d, GALLONS IINERT MATERIAL? ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED 6 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> CmOUNTY# JURISDICTION# FACILITY# TANK* SAM05Z <br /> STATE LD.# I �I J [T-nI I ILt I glo <br /> PERMIT NUMBER PERMITAPPROVED BY/DATE PERMIT EXPIRATION DATE 15--12-,C3 <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM AA HAS BSN FILED. <br /> l/ FOROOMBA6 <br />