My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
COMPLIANCE INFO 2011 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:57 AM
Creation date
11/5/2018 12:32:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2015
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUCKLEY COVE\4950\PR0231028\COMPLIANCE INFO 2011 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2015
QuestysRecordDate
12/12/2017 5:21:36 PM
QuestysRecordID
3746448
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:WWw.sjgov ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> RIVER POINT LANDING MARINA-RESORT' (209) 951-4144 January 21, 2015 <br /> Facility Addresa: EPA IU CERS la <br /> 4950 BUCKLEY COVE WAY, STOCKTON, CA 95219 1 10181441 <br /> Facility Contact: Contact Phone: Contact during inspection, if <br /> DUNN, RICHARD (209) 951-4144 different from facility contact: <br /> Inspection type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> CCR=California Code of Regulations HSC= eakh and arety Cade CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected oo site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate o V o R c COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V o R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST Operating Penna Application for Facility and Tank information not submitted or current o V o R o COS <br /> 105 HSC 25286(c) Current BOE number not submitted o V ❑R o COS <br /> 106 CCR 2632 Monitoring and response plans not wrent or approved by the EHD o V o R o COS <br /> 107 CCR 2632(d)(1)(C) Plot pian/site map not submitted or failed to completely show where monitoring is performed to V to R in COS <br /> 108 CCR 2637M,2638(e) Faded to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 109 CCR 2637 Faded to test secondary containment o V o R in COS <br /> 110 CCR 2637(e) Faded to submit secondary containment test report within 30 days o V o R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R n COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V c R o COS <br /> 113 CCR 2638(d) Felled to submit monitoring system certification test report within 30 days o V o R o COS <br /> 114 CCR 2636M Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down c V c R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days o V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess wrrent ICC certification o V o R o COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well o V o R in COS <br /> 118 HSC 25292.5 Faded to repair and retest system due to failed ELD test o V o R o COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days o V ❑R o COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R o COS <br /> 122 HSC 25299 Documents were falsified or misrepresented o V o R o COS <br /> 123 CCR 2661 Permit to repair UST system not obtained o V o R o COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V o R o COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V ❑R o COS <br /> 126 HSC 25404(e)(4) Failed to report program data electronically o V o R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions o V o R ❑COS <br /> I <br /> Received b (i ' ia1): Inspector. Phone: ate: <br /> FATINAH ZAREEF, REHS (209) 953-7311 01/21/2015 <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.