My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUDWEISER
>
3932
>
2300 - Underground Storage Tank Program
>
PR0231529
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2024 4:17:03 PM
Creation date
11/5/2018 12:36:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231529
PE
2381
FACILITY_ID
FA0003585
FACILITY_NAME
DELTA-SIERRA BEVERAGE LLC
STREET_NUMBER
3932
STREET_NAME
BUDWEISER
STREET_TYPE
CT
City
STOCKTON
Zip
95215
APN
10118036
CURRENT_STATUS
02
SITE_LOCATION
3932 BUDWEISER CT
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUDWEISER\3932\PR0231529\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
1/20/2012 8:00:00 AM
QuestysRecordID
111104
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iTATE OF CALIFORNIAWATER RESOURCES CONTRC 30ARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION P <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. G <br /> MARK ONLY 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑7 PERMANENTLY CL^ TANK so <br /> ONE ITEM ❑ 2INTERIM PERMIT ❑ 4 AMENDEOPERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED' <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YE8 NO N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 11 <br /> W <br /> A. OWNERS TANK ID q 49 R. MANUFACTURED BY: GG (� <br /> C.YEAR INSTALLED 6< D. TANK CAPACITY IN GALLONS: 0eaz <br /> II. TANK C NTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ETrI MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑4 OIL 1 PRODUCT ❑4 GASAHOL ❑5 JETFUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN REM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,8,C,&D <br /> A. TYPE OF ❑ I DOUBLEW ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARYOONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE El6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑B 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> ❑1 RUBBER LINED ALKYD LINING ❑3-,EPDXY LINING ❑4 PHENOLIC LINING <br /> C. INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑6 LINED ❑95UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH I METHANOL? ❑YES ❑NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENEWRAP ❑2 TAR OR HALT ❑3 VINYLWRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑9/ NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GRO\Lms U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSOR A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WA ED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2STAINLESS ST A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> : <br /> C. MATERIAL A U 5ALUMINUM A U CONCRETE A U 7STEELCLADW/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> 1L, <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR 8 FO SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> [., P 1 VISUAL CHECK 0 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WE P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> •J P 8 PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? [DYES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGF-IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION» AGENCY# FACILITY ID# TANKIDM <br /> 131161-1 = 0laIll <br /> CURRENT LOC L AGENCY FACILITY ID N APPROVED E PHONE 0 WITH MG CODE <br /> ) . 3C/ zaael' <br /> PERMIT N MBER PERMIT APPROVAL DA PERMIT EXPIRATION DATE <br /> HECK X PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(ADA) THIS FORM MUST BE ACCOMPANIEM A FACILITY/SITE APPLICATION, FORM 'A',UNLESS AWNRENr FORMA' HAS BEEN FRED <br /> �•,TA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.