My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUTTON
>
150
>
2300 - Underground Storage Tank Program
>
PR0232234
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:22:02 PM
Creation date
11/5/2018 12:38:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232234
PE
2333
FACILITY_ID
FA0003639
FACILITY_NAME
CARGILE, E Q
STREET_NUMBER
150
STREET_NAME
BUTTON
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
150 BUTTON AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUTTON\150\PR0232234\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
1/20/2012 8:00:00 AM
QuestysRecordID
111154
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD "• <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM ., <br /> TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> TANK <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑.5 CHANGE OF INFORMATION ❑�7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE Ip TANK REMOVED Q N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 5O )J FA11M TANK-YES❑ NO [e� � <br /> W <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID R <br /> B. MANUFACTURED BY: KJ�I W <br /> C. YEAR INSTALLED fqbe4 D. TANK CAPACITY IN GALLONS: '-S QC) <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. Ki MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ®3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL R] 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.R C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EKTERIOR UNER ❑95 UNKNOWN <br /> SYSTEM Ok2 SINGLE WALLED ❑4 SECONDARf CONTAINMENT ❑99 OTHER <br /> ❑i STEBUIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4 STEEL CLAD W/RBERGLASS REINFORCED PLASTIC <br /> B.TANK F-15 CONCRETE ❑6 POLWNYL CHLORIDE ❑ 7 ALUMINUM ❑8 IW%METHMO�LLC�1OOMPALF�FRP <br /> MATERIAL F]9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN �99 OTHER SLf__ 11 <br /> F-11 RUBBERUNED ❑2 ALKYD LINING ❑3 EPDXYUNING F-14 PHENOLICUNING <br /> C <br /> LINING GR ❑ 5 GLASS UNING ❑6 UNLINED ®.95 UNKNOWN <br /> ❑IS LINING MATERIAL COMPATIBLE WITH 1W%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENEWRAP ❑ 2 TAR OR ASPHALT ❑ 3 VIW'L WRAP ❑4 FIBEROUWREINFORCEDPLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A&1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 6DO5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 RBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A/UT�6�CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL ADM UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION S M MUST BE CIRCLED. <br /> r8 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 5 5 GROUND WATER MONITORING WELLS <br /> P 5 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [_—] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> t <br /> LOCAL.AGENCY USE ONLY <br /> COUNTY B JURISDICTION R AGENCY# FACILITY ID R TANK ID# <br /> ® = = loo2z3 - dao <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME / PNOHE#WITH AREA CODE <br /> C LT- �� �1 <br /> I <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGEAMT. FEE CODE RECEIPT# BY: 1, <br /> FORM 8(6-29-BB) THIS FORM MUST BE ACCOMPANI AFACILITY/SITE APPLICATION, FORM'A7,UNLESS M RENT FORM A• HAS BEEN FILED I <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.