My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 2:50:46 PM
Creation date
11/5/2018 12:44:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARDING\244\PR0231137\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/21/2016 11:31:35 PM
QuestysRecordID
3150426
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www sigov.orq/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />aMiracle Mile Market Facilrfyr244 W. Harding, Stockton =ion <br />NAug 27, 2014 <br />Name: me: Atldess: <br />403 <br />HSC 25290.c1(c)(2) <br />HSC 252 90.2 2 <br />Secondary containment not liquid or vapor tight <br />404 <br />HSC 25290.1(c)(3) <br />HSC 25290.2(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />405 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />HSC 25290.2(d) <br />liquid or vapor from the primary containment into the secondary containment <br />406 <br />HSC 25290.1(a) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />HSC 25290.2(i) <br />pressure test approved by SWRCB; 3 test method deemed equivalent to (1) or (2) by the SWRCB <br />Emergency Generator Systems <br />501 <br />CCR 2636(f)(6)Emergency <br />generator monitoring system not checked daily or log not kept if no leak detector (M7) <br />502 <br />HSC 25281.5(b)(3) <br />Unburied fuel piping not visually inspected at least monthly or log not kept (M7) <br />USTs in a Vault <br />601 <br />HSC 25283.5(a)(1) <br />All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 <br />HSC 25283.5(a)(2) <br />Structure that the UST is located in does not provide for secondary containment <br />603 <br />HSC 25283.5(a)(3) <br />Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 I I HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />.f';. Non -Pressurized Piping <br />1 701 1 1 1 1 CCR 2643(M I Dailv monitorina of suction oioina (ore -January 1, 1984) not oerformed IMM <br />Jeffrey Wong (209) 468-0335 <br />EHD 23-02 Rev 04/22/13 // Page 2 UST INSPECTION REPOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.