My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10998
>
2300 - Underground Storage Tank Program
>
PR0500063
>
REMOVAL_2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 2:02:49 PM
Creation date
11/5/2018 12:51:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2001
RECORD_ID
PR0500063
PE
2361
FACILITY_ID
FA0004559
FACILITY_NAME
BENETO TANK LINE
STREET_NUMBER
10998
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333030
CURRENT_STATUS
02
SITE_LOCATION
10998 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\10998\PR0500063\REMOVAL 2001.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �Mw <br />SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If contamination <br />is documented during closure, an Unauthorized Release Notification must be completed and submitted within five (5) working days <br />pursuant to California Health & Safety Code, Section 25295. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />MINIMUM NUMBER <br />of WATER SAMPLES <br />< 1,000 <br />1 r Tank <br />Fill OR Pump End of Tank <br />2 from wall next to tank <br />1,000 - 10,000 <br />5 per Tank <br />Single Tank:1 <br />3 <br />1,000 - 10,000 <br />2 r Tank <br />1 at each End of Tank <br />> 10,000 <br />3 or More <br />per Tank <br />Ends and Middle OR generally <br />spaced along the length of the Tank <br />PIPING AND STOCKPILE <br />PIPING SOIL SAMPLES 1 sample eve 20 lineal feet <br />F <br />TANK & PIPING To <br />SAMPLES 2 Samples every 50 cubic yards <br />1-11 or m♦XTV VyT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />W A 1 Pn 13 Illf'iJL'1�1 <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />a1 <br />LOCATION of SOIL <br />SAMPLES <br />MINIMUM NUMBER <br />of WATER SAMPLES <br />< 1,000 <br />< 10,000 <br />Center and Ends OR Sides of Tank <br />2 from wall next to tank <br />1,000 - 10,000 <br />5 per Tank <br />Single Tank:1 <br />3 <br />ends at soil/groundwater <br />1 <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />interface & 1 below tank <br />4 from wall next to tank <br />> 10,000 OR <br />ends at soil/groundwater <br />1 <br />Tank Cluster <br />5 or more <br />interface & I below each <br />tank <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />< 1,000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />1,000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />EH 23 046 (Revised 08/13/99) Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.