Laserfiche WebLink
6V�R E4 <br /> ,� Il STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B ads <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT n 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLYaCLOSED ON g E <br /> L 1 <br /> ONE ITEM 2 INTERIM PERMIT 4 AMENDED PERMIT L] 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOV O T <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.X ©t B. MANUFACTURED BY: /j�� tr�J we <br /> C. DATE INSTALLED(MDIDAWYEAR) �S D. TANK CAPACITY IN GALLONS: 1 00 V <br /> r} <br /> II.TANK CO S IFA-1ISMARKED,COMPLETE ITEM C. REGULAR <br /> V <br /> A [� 1 MOTOR VEHICLE FUEL --� 4 OIL B. C. <br /> ❑ 1aUN EA ED 3 DIESEL I: i 6 AVIATIONGAS <br /> n 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT 711b PREMIUM ❑ 4 GASAHOL ,- I 7 METHANOL <br /> UNLEADED u 5 JET FUEL <br /> 3 CHEMICAL PRODUCT ❑ 95-UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ gg OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED 0.A.S.9 <br /> III. TANK CONSTRUCT( ARK ONE ITEM ONLY IN BOXES A.8,AND C,AND ALL THAT APPLIES IN BDX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK � �ARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W7 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPAT€BLE WIFRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR f: 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP n 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION Q 5 CATHODIC PROTECTION ❑1 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED{YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) _.. <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FGERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL WI COATING A U 8 100% METHANOL COMPATIBLEW/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION 5 UNKNOWN A U 99 OTHER_ <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTINGA� <br /> NfTORING ❑T gg OTHER <br /> MO <br /> V.TANK LEAK DETECTION <br /> 177, 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING E] 5 GROUND WATER MONITORING <br /> 6 TANK TESTING 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> I.ESTIMATED DATE LAST USED(MO/DAYIYR) 2.ESTIMATED QUANTITY OF 3,WAS TANK FILLED WITH YES ❑ NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED 8 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISIDI�CTIO�N1# FACILITY# TANK# 26,4.4 <br /> STATE i.D.# ❑�� S `7 S �3 d <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORMA HAS BEEN FILED, i <br /> r l ola1-i% oRamtB Rs <br />