My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
17100
>
2300 - Underground Storage Tank Program
>
PR0231587
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 11:02:36 AM
Creation date
11/5/2018 1:00:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231587
PE
2361
FACILITY_ID
FA0000210
FACILITY_NAME
CARPENTER CO
STREET_NUMBER
17100
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19812004
CURRENT_STATUS
02
SITE_LOCATION
17100 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\17100\PR0231587\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
11/14/2016 9:06:47 PM
QuestysRecordID
157642
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"c NEW UST INSYALLATION RECORD <br /> '4FACILTIY NAME P��CAZ rn PPaV rJC <br /> FACII.iTY ADDRESS —/7/00 <br /> SWEEPS # TANK# U.L.# PRODUCT <br /> DATE APPROVED DISAPPROVED REHS ITEM OR EQUIPMENT INSPECTED <br /> 1. UST INSTALLATION PLANS SUBMITTED &FEES PAID <br /> 2. UST INSTALLATION PIANS APPROVED <br /> INITIAL INSPECTION <br /> 1. HOLIDAY TEST(PLASTEEL) <br /> 2. AIR TESTED @ 5 PSI (FRP) <br /> 3. VISUAL INSPECTION OF 20 CONTAINMENT r: <br /> 4. TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL <br /> PIPING STAGE INSPECTION <br /> I. PRESSURE TEST 110 AND 20 (NFPA 30)] <br /> 2. BALI.HAAT VALVES INSTALLED <br /> 3. OVERFILL PROTECTION INSTALLED, DESCRIBE: <br /> .4. UNUSED TANK OPENING SEALED & CATHODICALLY PROTECTED <br /> S.'VISUAL INSPECTION OF 20 CONTAINMENT ON PIPING <br /> 6.:MONITORING PORTS IN PLACE &BROUGHT TO GRADE (LOCKABLE <br /> WEATHER PROOF'COVERS) <br /> 7. FILL&VENT PIPING BROUGHT TO GRADE <br /> 8. PRODUCT LINE LEAK DETECTOR INPLACE (HARD WIRED) <br /> 9. APPROVED UST LEAK MONITORING DEVICE INSTALLED <br /> 10.ALL GALVANIZED PIPING &FITTINGS PROPERLY WRAPPED <br /> 11.PRESSURE DECAY TEST ON COMPLETE UST& PRODUCT DELIVERY <br /> SYSTEM <br /> FINAL INSPECTION <br /> 1. PRECISION TEST SUCCESSFULLY COMPLETED AND HARD COPIES <br /> RECEIVED (NFPA 329) <br /> 2. SPILL PROTECTION AT FILL PIPE <br /> 3. PERFORMANCE TEST OF OVERFILL PROTECTION SYSTEM <br /> 4. PERFORMANCE TEST OF PRODUCT LINE LEAK DETECTOR (HARD <br /> WIRED) <br /> S. PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM(S) ON <br /> TANK(S) <br /> 6. PERMIT TO OPERATE APPLICATION COMPLETE <br /> 7. ACCEPTABLE RECORD KEEPING SYSTEM <br />