Laserfiche WebLink
a`t'JNIFIED PROGRAM CONSOLIDATED FLT.M <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One Form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430 <br /> 0 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ S.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430° I DATE EXISTING UST DISCOVERED: 430E <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) iLs 3 <br /> EAST HARNEY ARCO �I <br /> B255EE SI10J C <br /> HARNEY LANE ITY LODI la <br /> ADDRESS <br /> H.TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> 1 TA 052 0 538 ■1.A STAND-ALONE TANK <br /> XERXES [12.ONE INA COMPARTMENTED UNIT. <br /> C len me pule for each mm mtia the milt. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> N/A 25, 000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE Is.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Usd oil ❑ 5.EMERGENCY GENERATOR FUEL DISC$25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 43% <br /> CONTENTS PETROLEUM: la.REGULAR UNLEADED ❑ la MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ R.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 4400 <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM S xi : 44ub <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ LS LE WALL N 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PR04ARY CONTAINMENT ❑ 1.STEEL E 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 4440 <br /> SECONDARY CONTAINMENT ❑ 1.STEEL N 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN [199.OTHER(Si ): 4450 <br /> OVERFILL PREVENTION 1.AUDIBLE&VISUAL ALARMS 2.BALL FLOAT 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑I.SINGLE-WALLED 0 2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE I.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR 12636(a)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL 0 4.FIBERGLASS ❑ R.FLEXIBLE ❑ I0.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 0640 <br /> SECONDARY CONTAINMENT ❑ L STEEL 0 4.FIBERGLASS ❑ R.FLEXIBLE ❑ 10.RIGID PLASTIC abw <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): a6ac <br /> PIPING/TURBINE CONTAINMENT SOME TYPE ❑ 1.SINGLE WALL 0 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ I.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99,OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ I.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 461r <br /> 4641 <br /> VR PRIMARY CONTAINMENT ❑ L STEEL 4.FIBERGLASS ❑ 10.RIGIDPLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464g <br /> 464 I <br /> VR SECONDARY CONTAINMENT ❑ L STEEL 4.FIBERGLASS ❑ 10.RIGIDPLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 90.NONE 4641 <br /> RISER PRIMARY CONTAINMENT 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464j <br /> 4 jl <br /> RISER SECONDARY CONTAINMENT ❑ L STEEL E3 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED 1.SPILL BUCKET E 3.STRIKER PLATE/BOTTOM PROTECTOR 0 4.CONTAINMENT SUMP 451a< <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.N 464a <br /> CONSTRUCTION MATERIAL ❑ L STEEL 0 4.FIBERGLASS [1l0.RIGID PLASTIC ❑ 99.OTHER(Specify) _ 4696K <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION <br /> IX. APPLICANT SIGNATURE IN <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herq1jigrue,accurate, <br /> and in full compliance with legal requirements. <br /> APPLICANT SIGNATURE DATE470. <br /> 2/25/13 <br /> APPLICANT NAME(print) 471. APPLICANT TITLE Design Engineer 472 <br /> Jonathan Ramos <br /> UPCF UST-B-I/2 t( � Rev.(12/2007) <br />