My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1986
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOGAN
>
5154
>
2300 - Underground Storage Tank Program
>
PR0500285
>
REMOVAL_1986
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2021 4:58:09 PM
Creation date
11/5/2018 1:10:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1986
RECORD_ID
PR0500285
PE
2333
FACILITY_ID
FA0004712
FACILITY_NAME
WILLIAM BURKHARDT
STREET_NUMBER
5154
STREET_NAME
HOGAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06112001
CURRENT_STATUS
02
SITE_LOCATION
5154 HOGAN LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOGAN\5154\PR0500285\REMOVAL 1986.PDF
QuestysFileName
REMOVAL 1986
QuestysRecordDate
5/24/2013 8:00:00 AM
QuestysRecordID
168686
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MI 1UM VERIFICATION LABORATORY ANA J YSIS <br /> TANK TANK TPH-G TPH-D BTX & E CL HC TOTAL EDB METALS <br /> 8278 <br /> CB <br /> # CONTENTS 8015 8015 8020 8010 LEAD <br /> 8260 8260 8260 8240 . 7420 8240 AES <br /> or 8080 <br /> 7421 <br /> IX <br /> LEADED X X <br /> OAS X X <br /> UNL GAS X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WASTE\ X X <br /> USED OIL X X X X <br /> All analyses methods are designated EPA methods described in EPA SW 846, Third Edition. Those methods not found <br /> in SW 846, are specifically noted below. Refer to the "SWRCB LUFT Field Manual% Appendix A-20, Table 3-5 for <br /> detection limits of motor vehicle fuels (gasoline and diesel). Refer to 1-2-3 "Regional Board Staff Recommendations for <br /> Initial Evaluation and Investigation of USTs" for the waste and motor oil detection limits. <br /> I)etectlon Limits that remain below the MCI., STLC or Allowable Limit or the contaminant In question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> 7TH-0 Total Petroleum Hydrocarbon, Gasoline, OC/FID (5030) 8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or GCIMS 8260 <br /> BTX & E Benzene, Toluene, Xylene & Ethyl Benzene, GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 <br /> TOTAL LEAD Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> EDB Ethylene dibromide (DHS-AB 1803), GC/MS 8240 (DHS-LUFI) <br /> GC-FID Gas Chromatography, Flame Ionization Detection <br /> ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel. <br /> PCB Polychlorinated Blphenyls, GC/MS 8270 or 8080 <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. Fused capillary columns are <br /> preferred to packed columns; a packed column may be used as a 'first cut' with "dirty" samples or once the hydrocarbons <br /> have been characterized and proper QA/AC is followed. <br /> For Drinking water sources, EPA recommends that the 500 series for volatile organics be used in preference to the 600 <br /> series because the detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal <br /> contamination may require further analysis. PHS-EHD recommends holding these samples until disposal is Indicated. <br /> EH 23 048 (Revised 7/10/92) Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.