Laserfiche WebLink
SAN JOAQUIN COON" 'JBLIC HEALTH SERVICES/ENVIRONMENTAL HEALTH r"„ ISION <br /> I• UGS%.wORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> NAME OF FACILITY SWEEPS CODE <br /> ADDRESS TANK ID #11.9 - <br /> TANK SIZE111r.90 FUEL TYPE �& <br /> II. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit # - Facility Status Code Doc.Soil/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) V NIG Type of Tank Steel FbrgL I ellngl Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> SoiL Samples Received Yes No Depth to Ground Water f Ref/Year Average Annual Precipitation A= 14 10-25 <br /> On-Site Wetl(s) Yes Na Number 8 Type Irr Dan Pub <br /> S Score S Scare B Score <br /> Distance to WeLL(s) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R ndition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E +rs met <br /> Minim m Depth to groundwater from the Soil Sample (feet) o-.5 <br /> feet) p 5 >100 51-100 -50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10- xxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Un own Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxx None one one <br /> COLUMN TOTALS>>>TOTAL POINTS + + <br /> Sample Result: (B T % OR E) RANGE OF TOTAL POINTS 49 pts or mor 41 - 48 pts 40 pts or Less <br /> Tl _(:Yi a” N D <br /> �fM 1xW B T X E B T % E <br /> , , &etoD MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> •$ TPH O DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soi'L or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> %3 Levels for BTXBE are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX 8 E or TPH Concentrations > Allowable Levels *Yes No <br /> 2. Recommend Site Closure Yes No I *If Yes, Refer to Site Mitigation for Evaluation <br /> VII. REVIEW EVALUATION - TO BE COMPLETED e A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />