My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOWLAND
>
16777
>
2300 - Underground Storage Tank Program
>
PR0503182
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 4:14:10 PM
Creation date
11/5/2018 1:32:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0503182
PE
2381
FACILITY_ID
FA0000187
FACILITY_NAME
JR SIMPLOT CO
STREET_NUMBER
16777
STREET_NAME
HOWLAND
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19818005
CURRENT_STATUS
02
SITE_LOCATION
16777 HOWLAND RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOWLAND\16777\PR0503182\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
4/24/2017 3:55:49 PM
QuestysRecordID
167459
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEOMWMIX <br /> 6.7 Closure of Underground Storage Tank <br /> The underground storage tank is a buried steel tank encased in concrete. The tank will be <br /> removed during closure activities and transported to an plastic lined area within the rail car loading <br /> area. Prior to removal, any sludge or tank residuals will be removed, <br /> Once the tank has been moved to the lined area, the top of the tank will be exposed and the <br /> interior will be bydroblasted. Rinseate from the hydroblasting will be stored in a Baker Tank, <br /> tested for hazardous waste characteristics, and disposed of as hazardous waste, if necessary. If <br /> non-hazardous, the rinseate will be disposed of at a permitted hazardous waste disposal facility. <br /> It is assumed that approximately 100 gallons of rinseate will be generated. Closure of the tank <br /> will be demonstrated by collecting a final rinseate samples. The sample will be analyzed for DBCP <br /> and EDS using EPA Method 8011, organochlorine pesticides using EPA Method 8080, and <br /> organophosphorus pesticides using EPA Method 8140. Clean closure will be achieved if the <br /> results of the analyses are all non-detect. Upon demonstration of clean closure, the tank will be <br /> disposed of as non-hazardous. If clean closure is not achieved, the tank will be disposed of as a <br /> hazardous waste. <br /> A total of two soil samples will be collected within the bottom of the tank excavation. If <br /> groundwater is encountered in the bottom of the excavation, the samples will be obtained from <br /> the excavation sidewalls. The approximate location of the samples are indicated on Figure I The <br /> actual locations will be determined by the licensed engineer during closure. <br /> Soil samples will be collected using a drive sampler fitted with pre-cleaned brass sample tubes, <br /> The samples will be collected approximately 6 to 8 inches below the excavation surface. The drive <br /> sampler will be cleaned between sample locations. The tubes will be sealed with plastic end caps <br /> and tape. The samples will be sealed, labeled, and placed in an iced cooler for transport to the <br /> laboratory under chain-ofcustody procedures. The soil samples will be analyzed for DBCP and <br /> EDB using EPA Method 8011, organochlorine pesticides using EPA Method 8080, and organo- <br /> phosphorus pesticides using EPA Method 8140. <br /> If the soil samples contain hazardous waste concentrations of pesticide residues,depending on the <br /> quantities involved, Simplot may arrange to remove, treat (if necessary), and dispose of the soil <br /> at a permitted hazardous waste landfill. Groundwater below the site is being collected and treated <br /> to remove pesticide residues, as described above in Section 2-5, The soil surface over most of the <br /> Ag Chem area is paved. new conditions provide effective controls for exposure routes and <br /> cleanup beyond hazardous waste cdncentrations does not appear warranted. <br /> 12 <br /> I <br /> ZO 'd C5t81 NOW 66-Z1-83S <br />