My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUTCHINS
>
121
>
2300 - Underground Storage Tank Program
>
PR0507891
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2021 11:40:06 AM
Creation date
11/5/2018 1:38:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0507891
PE
2381
FACILITY_ID
FA0007824
FACILITY_NAME
CITY OF LODI
STREET_NUMBER
121
Direction
S
STREET_NAME
HUTCHINS
STREET_TYPE
ST
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
121 S HUTCHINS ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HUTCHINS\121\PR0507891\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/28/2013 8:00:00 AM
QuestysRecordID
169309
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r /H!•e STATE OF CALIFORNIA <br /> e STATE WATER RESOURCES CONTROL BOARD 5 a <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B �� =� <br /> ( <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: t— - <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.• .K B. MANUFACTURED BY: v <br /> C. DATE INSTALLED(MOHDAY/YEAR) /C D. TANK CAPACITY IN GALLONS: 00 <br /> IL TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A ❑ 1 MOTOR VEHICLE FUELOIL 8. C. 18 REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> F7 2 PETROLEUM 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ ] METHANOL <br /> 8 M85 <br /> E:] 3 CHEMICALPRODUCT ❑ 95 UNKNOWN 2 WASTE ❑❑ 2 MLE DEDE UNLEADED 6 JOTHER(DESCRET FUEL ❑IBE IN ITEM D.BELOW) <br /> 0. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED B �/� ,G!` C.A.S.k <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ i DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ I BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑ 2 ALKYD LINING �❑ 33 EPDXY LINING E:] 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED Sf95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 10D% METHANOL? ES_ NO— <br /> D.EXTERIOR ❑ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ Bl NONE 95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL,610. SPILL CONTAINMENT INSTALLED(NEAR) OVERFILL PREVENTION EOUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A&i SINGLE WALL A U 2DOUBLE WALL A U 3 LINED TRENCH A 5 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND AO1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION1 NEOWarx ME IFAHc 2 ME 11GRTNE38 3 wrOwuaufi INreAS 4 EIEm C ME 5 AOIOMATw RIMP <br /> ❑ DE mw ❑ TESMG ❑ Mnwmnw9 IFAK OEIECTGII ❑ SHNDOWN 99 OTHER //.K <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 <br /> ❑ MANUAL INVENTORY ❑ 3 ❑ 4 C TANK ❑5 WATER ANNUALTMK <br /> ECO IUATONMONITORING GAUGING MONITORINGTESTING <br /> 7 CONTINUOUS INTERSTITIAL ❑ a SIR 97ELYMUAL ❑ 10 MONTHLY TANK 95 UNKNOWN 99 OTHER <br /> MONITORING NWEEKLY <br /> GAUGING <br /> NG <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE T US (MOADAY]YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? ❑ ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED a SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY M JURISDICTION N FACILITY# TANK a �7' <br /> STATE LDS 3 0 7 8 a 7 6/ <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLA'- 'ILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE V RGROUND STORAGE TANK REGULATIONS <br /> FORM B (6.95) �( <br />
The URL can be used to link to this page
Your browser does not support the video tag.