Laserfiche WebLink
04/26/1999 07:11 7146705420 EHS ARCO LA PALMA PAGE 04 <br /> STATE Of CALIFONOA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B : �_- ' "' <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY Ej 1 NEW PERMIT ❑ 3 RENEWAL PERMIT S CHANGE OF INFORMATION ❑ PERMANENTLY CLOSED CN SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK 1S INSTALLED: py��,p 'r%L ti10. Lqq <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK L D.a Z_V L�-� B. MANUFACTURED BY! <br /> C. DATE INSTALLED(MO/DAYNEAR) 1Z 8 D. TANK CAPACITY IN GALLONS; <br /> 11.TANK CONTENTS IFA-I IS MARKED,COMPLETE ITEM C. <br /> A. L� MOTOR VEHICLE FuEL ❑ 4 .OIL g C L�( to REGU!AR 3 DIESEL <br /> UNLEADED —� 6 AVIATION GAS <br /> 2 PETROLI=UM ❑ 80 EMPTY PgODUCT ❑ 1bpREM1UM 4 13ASAHOL I <br /> UNLEADED 5 JETFUEL ❑ 7 METHANOL <br /> [] 3 CHEMICAL PRODUCT ❑ 96 UNKNOWN ❑ 2 WASTE 2 LEADED <br /> ❑ 99 OTHER (DESCRIBE IN ITEM O. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED —' <br /> C.A.S.a; <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A:B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL. WITH EXTERIOR LINER <br /> ❑ 95 UNKNOWN <br /> SYSTEMJ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER_ <br /> 8. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL [jj� FIBERGLASS ❑ 4 STEEL,CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL f_ a 6 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 0 100% METHANOL COMPATIBLE WiPRP <br /> (FrlmaryTank) j 9 13RONZE ❑ 10 QALVAN¢ED STEEL ❑ US UNKNOWN ❑ g9 OTHER <br /> ❑ 1 RUBBER <br /> BER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LININQ_� <br /> C,INTERIOR Ca 5 GLASS LINING NG ❑yes UNLINED ❑ 95 UNKNOWN ❑ SB OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 1009E METHANOL? YES, NO— <br /> D.CORROSION YIN'❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP Ej�q FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 1 5 CATHODIC PROTECTION ❑ 91'.NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV,PIPING INFORMATION CIRCLE A IF ABOVEI3ROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE _ A U 1 SUCTION AQ 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION 701 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH p U 45 UNKNOWN A U 99-OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESB STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U d FIBERGLASS PIPE ^ <br /> CORROSION A U 9 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B IDD% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 93 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION / AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 3 MONITORING [:]99 OTHER <br /> V.TANK LEAK DETECTION <br /> VISUAL CHECK [❑ 7. INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITCRING 1 <br /> L�re TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED QA F LAS USED(MO/DAYNR) Z ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> tri SUBSTANCE REMAINING GALLONS INERT MATERIAL 7 YES ❑ NC ❑il <br /> THIS FORM HA BEEN COMPLETED UNDER PENALTY OF RJ PY,AND TO TWE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANT'S NAME DATE <br /> (PRINTED A 8I0NA7UpF //'7//� - 7 C_ <br /> LOCAL AGENCY USE ONLY THE STATE LD,NUMBER IS C OSED OFTHE FOUR NUM RS BELOW <br /> STATE LD.# <br /> COUNTY# JURI ICTION X FACILITY v TANK# <br /> ❑❑ <br /> PEr1Mir NUMBEq PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> FORM B (7.91) THIS FORM MUST HE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORa¢748-R,5 <br />