614 7069 Adhesive Kits <br /> F.�} 'k'g'�RED THREAD° and UL-Listed RED THREAD IIA Piping Systems <br /> Wote: This bulletin contains limited installation information. It is important to read and fully understand the instructions in Manual No. F6000 <br /> for standard products or Manual No. 82160 for UL-Listed products before beginning installation. Ambient temperature,adhesive working life, <br /> and number of crewmen should be considered when ordering adhesive. For long runs of 8'and larger pipe,one kit per joint is recommended. <br /> 7014 KitkBonds <br /> 7024 Kit 7069 Kit <br /> Contents it Contents Bonds Per Can' Contents Bonds Per Kit <br /> g Pipe Pipe <br /> Size Size <br /> Description Qtyo. Description Qty. Inches No. Description Qty. Inches No. <br /> 2.6 oz.Can Mixed 2 2 9 10.1 oz.Can 1 6 8 <br /> 6.9 oz.Can 15Adhesive Mixed Adhesive <br /> Mixed Adhesive1.5 oz.Container 180.6 oz.Container 2 3 6 2.3 oz.Container 1 8 4 <br /> Hardener Hardener <br /> Hardener <br /> 1"Paint Brush 10 1" Paint Brush 2 4 4 2"Paint Brush 1 10 3Mixing Stick 1Mixing Stick 2 6 2 Mixing Stick 1 12 2 <br /> Vinyl Gloves 1 pVinyl Gloves 2 pr. 8 1 Vinyl Gloves 1 pr. 14 2 <br /> 'Total for both kits is double the number of joints. <br /> __ 161 <br /> The 7000 series adhesives are room temperature,two component, epoxy adhesive systems. Once mixed, the adhesive's working life is limited <br /> to approximately 25 minutes at 75OF. Adhesive is recommended for use with NOV Fiber Glass Systems piping systems in recommended services <br /> where continuous service temperatures do not exceed 150OF _ <br /> Precautions <br /> Testing piping systems with air or gas is not recommended Adhesive that is allowed to setup (harden) in the metal <br /> due to Inherent safety;concerns.. Refer to NOV Fiber Glass container willundergo an exothermic reaction. Depending <br /> System's installation Manual No F6000 or F6300 for hydro on the quantity of adhesive, the reaction may generate foul- <br /> testing procedures. smelling smoke and temperatures up to 400'F (204°C).; An <br /> exotherming container of adhesiveshouldbe moved to a well <br /> Gloves and;eye protection should be worn when working ventilated area or outdoors. During this process wear gloves <br /> with adhesive components. Direct contacts may cause skin and avoid Inhalation of the smoke.' <br /> irritation. If Contact Is made with skin wash area with'.soap <br /> and water until contamination is removed. Eyes should be The user should read and follow solvent manufacturers'safety <br /> flushed with clean water and evaluated by trained medical recommendations when working with solvents. <br /> personnel. The work area should be well ventilated and direct <br /> inhalation of fumes should be avoided. <br /> POT LIFE OF ADHESIVE JOINT PREP <br /> The pot life (working life) of an adhesive is the time it takes for A strong adhesive bond requires clean bonding surfaces. The <br /> the adhesive to begin to harden in the mixing can. The life is bonding surfaces must be free of oily fingerprints, dirt, oils, <br /> measured from the time the hardener and adhesive are first grease and other contaminants. Freshly tapered spigots or <br /> mixed. Though the pot life is quite short at high temperatures, factory-fresh spigots and bells do not require cleaning unless <br /> it increases as the temperature drops below 75°F(24°C). visibly contaminated. Soil or dirt may be removed by washing <br /> with water. Surfacesmay-be-cleaned with acetoneor methyl <br /> The pot life of adhesive in hot weather can be extended by ethyl ketone when necessary. <br /> keeping the adhesive cool or by reducing the concentrated <br /> mass of adhesive in the can.This can be easily accomplished The surfaces should be dry before applying adhesive. Once <br /> in the field as follows: the surfaces have been cleaned, do not contaminate them by <br /> touching with hands, laying pipe in the dirt, etc. <br /> • Cool the can by wrapping with rags or paper towels, and <br /> then keep the wrappings wet with water or solvent. The Warning: Acetone and methyl ethyl ketone are extremely <br /> can will be cooled by evaporation of the water or solvent. flammable. When using these solvents, do not smoke or use <br /> Do not put water or solvent in the adhesive. near an open flame. Never use gasoline, turpentine, or diesel <br /> fuel to clean joints. <br /> • Reduce the concentrated mass by removing the mixed <br /> adhesive from the can and spreading the adhesive into a ADHESIVE MIXING <br /> thin film onto a piece of tin or aluminum foil. This aids the The ideal temperature range for mixing the adhesive base and <br /> dissipation of heat generated by the curing process. hardener is 70°-80"F(21°-27°C). <br /> To mix, pour the entire contents of the hardener container into <br /> the adhesive container. DO NOT SPLIT A KIT. Mix the adhesive <br /> and hardener together with the wooden mixing stick. <br /> wwww.fgspipe.com ,, <br />