My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2014 B100
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
INSTALL_2014 B100
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 11:07:34 AM
Creation date
11/5/2018 3:05:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2014 B100
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\J\JACK TONE\1501\PR0505264\INSTALL FILE B100 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
463
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
--------------------- --- ------— _ — ----------------- ----- <br /> Prefabricated Deadmen Installation Instructions <br /> For Fiberglass Underground Storage Tanks and OilM/ater Separators <br /> 1.GENERAL <br /> 1.1.These instructions supplement the Anchoring Tanks section of the <br /> These anchor points protrude up through the slots in the deadmen and are <br /> Xerxes Installation Manual and Operating Guidelines(subsequently temporarily supported with cotter pins.(See FIGURE2.2.) a <br /> referred to as"Installation Manual').They apply to pre-engineered, Chain or Sling / 60,to 90° <br /> prefabricated deadmen supplied by Xerxes. Anchor point _ Anchor point <br /> 1.2.It is important to follow the procedures and instructions in the Alignment slot Alignment slot <br /> Installation Manual in order to safely and properly install a Xerxes <br /> underground storage tank and accessories.Failure to follow those 1� <br /> instructions may void the tank warranty and cause tank failure,death, <br /> serious personal injury or property damage. <br /> 1.3.Deadmen help anchor tanks in installations in which there is potential FIGURE 2.2 <br /> for a high water table or trapped water. 2.3.2.Use only one strap per anchor point. <br /> 1.4.Deadmen come in various lengths.Generally,there are 1 to 4 deadman 2,3.3.Align the anchor paints with the hold-down strap locations on the <br /> sections per side of the tank,with both sides having an equal number, tank(marked by arrowhead IN -4 symbols).SeeAnchoring Tanks section <br /> 2,ANCHORING TANKS of the Installation Manual. <br /> 2.1.Xerxes Prefabricated Deadmen 2.3.4.When using deadmen in man-out-of-hole strapping applications, - <br /> 2.1.1.Xerxes-supplied prefabricated deadmen are pre-engineered and align the anchor points with the proper ribs before setting the deadmen in <br /> sized to the tank ordered and include galvanized adjustable anchor points the hole. <br /> (subsequently referred to as"anchor points").As with any deadman, 2.3.5.Care should be taken to keep backfill from entering the alignment <br /> water-table height,number of attached collar risers and burial depth must slots until Final adjustment is made.Placing something(for example,a <br /> be considered in sizing the deadman system. piece of wood)over the slots during backfill placement may help keep <br /> 2.2.Placement of deadmen backfill from entering the alignment slots. = <br /> 2,2,1.The minimum spacing between tanks must be increased as needed 2.4.Installation of deadmen <br /> to accommodate deadmen. 2.4.1.The top of the deadmen should be aligned to the bottom of the tank. <br /> 2.2.2.Always provide sufficient clearance to allow the deadmen to be set 2,4.2•The deadmen are typically placed directly on the excavation floor. <br /> outside of the lank"shadow."See Tank Spacing subsection in the 2.4.3.If Xerxes 18-inch wide low-profile deadmen are used as a E` <br /> Excavation Parameters section of the Installation Manual.(See FIGURE 2-1.) construction guide,they may need to be elevated.This can be <br /> accomplished by putting 3-112 inch of backfill or a wood 44(or <br /> equivalent)undemeath,so that the top of the deadmen are 12 inches off <br /> of the bottom of the excavation.(See FIGURE 2-3.) (_ <br /> i` Hold-dowh strap 2.4.4.Make sure the anchor points are positioned correctly. <br /> i9l E <br /> 'Al 2.4.5.Some contractors use the deadmen as a guide for proper depth of <br /> I Tank bedding.(Note that low-profile deadmen are not 12 inches high.) <br /> + _Turrhuckle ' - <br /> 18"-wide low-profile deadmen _ <br /> Backfill 44 <br /> f II, r � s i _ ♦ f <br /> �. r <br /> Anctro <br /> r t point 11II pI _f- <br /> 4 . TSlotted —Ill�l lll�l t ,l,l. I Ii9lj�!�I --�III,�� I <br /> deadman <br /> ~ FIGURE 2.3 <br /> FIGURE 2-1 <br /> 2.2.3.When multiple sections are used,the deadmen are to be butted 3.OPTIONAL TURNBUCKLES ; <br /> together end-to-end on each side of the tank. 3.1.General f <br /> 3.1.1.Xerxes also offers a turnbuckle(See FIGURE 3-1.)that will connect <br /> WARNING the deadman anchor point to the Xerxes FRP hold-down strap.When the <br /> deadman is properly positioned,this will eliminate the use of cables and <br /> Only use the anchor points when lifting and positioning the cable clamps.See Hold-down Straps subsection in the Anchoring Tanks = <br /> deadmen.A spreader bar may be required to lift longer sections of section of the Installation Manual for more detail.(Also see FIGURE 2-1) <br /> deadmen.Use guy ropes to guide the deadmen when lifting.Failure <br /> to do so could result in death or serious injury. <br /> 2.3.Positioning of anchor points <br /> 2.3.1.Xerxes deadmen are supplied with 314-inch-diameter anchor points. FIGURE 3.1 <br /> XERXE1� <br /> CORPORATION <br /> 7901 Xerxes Avenue South, Minneapolis, MN 55431-1288 ■ (952)887-1890 ■ Fax(952)887-1882 ■ www.xerxescorp.com <br /> O 2004 Xerxes Corporation xpd04/051h <br />
The URL can be used to link to this page
Your browser does not support the video tag.