My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
20360
>
2300 - Underground Storage Tank Program
>
PR0503553
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 3:49:55 PM
Creation date
11/5/2018 3:17:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503553
PE
2332
FACILITY_ID
FA0005877
FACILITY_NAME
SWIER, LARRY
STREET_NUMBER
20360
Direction
S
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
04
SITE_LOCATION
20360 S JACK TONE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\J\JACK TONE\20360\PR0503553\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
12/27/2016 9:20:15 PM
QuestysRecordID
3299567
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIb WATER RESOURCES CONTR�OARD <br /> FORM 'B': UNDE GROUND STORAGE TANK PRO RAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING ORMATION FOR EACH TANK. __ Z <br /> MARK ONLY ❑ <br /> 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK (O <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: <br /> c903& IrlARM TANK-YES NO ❑ (,V <br /> I. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY ~ <br /> A. OWNERS TANK ID qLX CID <br /> B. MANUFACTURED BY: (0 <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: J �d <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> E:] 5 HAZARDOUS ❑ 80 EMPTY 2 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&CAS.N C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ I DOUBLE WALLED 3 SINGLE WALLED WITH EXTERIOR LINER N415UNKSOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK MATERIAL F—] 5 CONCRETE 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE ERP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ I RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED E�$S.NIflfNbWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP ❑2 TARORASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE [.86-tlN WN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A. 5 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUMA U CONCRETE A U 7 STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ElYES E:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED A SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> E <br /> /NC'Y�FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> I, al PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE I RECEIPT# g ; .� <br /> FORM B(s-zs-ee) THIS FORM MUST BE ACCOMPAN BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS URRENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.