Laserfiche WebLink
' ED PROC-RAM r0NR0N.TTIATVT)FTT <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> Pae of <br /> VI.PIPING CONSTRUCTION(Cheok all thatapply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE WLl.PRESSURE D 2.SUCTION D 3.GRAVITY 458. ,1.PRESSURE D 2.SUCTION D 3.GRAVITY 459, <br /> CONSTRUCTION/ D I.SINGLE WALL D 3.LINED TRENCH D 99.OTHER 460. ❑1.SINGLE WALL D 95.UNKNOWN 462. <br /> MANUFACTURER <br /> 2.DOUBLE WALL ❑95.UNKNOWN X2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER 461, MANUFACTURER 463. <br /> D 1.BARE STEEL D 6.FRP COMPATIBLE W/100%METHANOL D 1.BARE STEEL D 6.FRP COMPATIBLE W/100%METHANOL <br /> D 2.STAINLESS STEEL D 7.GALVANIZED STEEL D 2.STAINLESS STEEL [17.GALVANIZED STEEL <br /> D 3.PLASTIC COMPATIBLE WITH CONTENTS D 95.UNKNOWN D 3.PLASTIC COMPATIBLE W/CONTENTS [18.FLEXIBLE(HDPE) D 99.OTHER <br /> Q.Q 4.FIBERGLASS D 8.FLEXIBLE(HDPE) D 99.OTHER D 4.FIBERGLASS D 9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING D 9.CATHODIC PROTECTION 464. D 5.STEEL W/COATING D 95.UNKNOWN 465, <br /> VIL PIPING LEAK DETECTION(Check all that apply)(A description ofthe mDnhonag program shall be submitted to the local agoacy.I <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466, SINGLE WALL PIPING 467. <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> D 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP D 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> SHUT-OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> [12. MONTHLY 0.2 GPH TEST 02. MONTHLY 0.2 OPH TEST <br /> [13. ANNUAL INTEGRITY TEST(0.1 GPH) D 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [14. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> [15. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING <br /> [3INTEGRITY TEST(0.1 GPH) 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): 06. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> 07. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW D 7. SELF MONITORING <br /> 09. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> [18. DAILY VISUAL MONITORING <br /> E39. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> D a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> D b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑It. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Dc. NO AUTO PUMP SHUTOFF Dc. NO AUTO PUMP SHUTOFF <br /> of 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT <br /> OFF OR RESTRICTION ❑11. AUTOMATIC LEAK DETECTOR <br /> C6 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> [113. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS D 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> [314. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF [114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> [115. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW [115. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> [116. ANNUAL INTEGRITY TEST(0.1 GPH) [116. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 117. DAILY VISUAL CHECK D 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 468 V1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 04. DAILY VISUAL CHECK 469. <br /> DATE INSTALLED [12. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS D S. TRENCH/LINER MONITORING <br /> 01 CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR D 6. NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the information proR ded herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OWIyER/OPERA DATE: o(F q N _ Q 470. <br /> A/vl/ 0 � 4 <br /> NAME OF OWNER/OPERA OR(print): TITLE OF OWNER/OPERATOR: 472' <br /> SANa� S/A/ t-7-7P <br /> dL9Mssz lA�ib� <br /> Permit Number(Agency use only) 473. Permit Approved By(Agency ase only) 474. Permit Expiration Date(Agency use only) 475. <br /> UPCF hwfwrc-b(1/99)-3/4 http://www.nuidoes.org Rev.02/16/00 <br />