Laserfiche WebLink
GROUNDING DETAIL SINGLE LINE DIAGRAM LEGEND and ABBREVIATIONS ELECTRICAL GENERAL NOTES <br /> (EXISTING/DEMOLITION) ELECTRICAL PANEL FLUSH MOUNT SMOKE DETECTOR 1 . SHOULD A CONFLICT OCCURS BETWEEN OR WITHIN THE SPECIFICATIONS <br /> L O O _ ELECTRICAL PANEL SURFACE MOUNT -0 ANV <br /> O O OR DRAWINGS, CODES, STANDARDS, REQUIREMENTS, MANUFACTURER'S <br /> ---- --� -ice"- �� FUSED SWITCH INS RUCTIONS OR RECOMMENDATIONS, THE MORE STRINGENT AND/OR <br /> I RESTRICTIVE CONDITION SHALL HAVE PRECEDENCE, AS DETERMINED BY <br /> dam--- (EX.) OVERHEAD FEEDER ® MAIN SERVICE SWITCHBOARD ® MOTOR STARTER THE CONTRACTING OFFICER. <br /> TAG AND IDENTIFY I TO POWER CO. P.O.C. <br /> EACH GROUND CIRCUIT BREAKER •DPP POWER POLE 2. THE DRAWINGS REPRESENT THE FINISHED PROJECT UNLESS OTHERWISE <br /> 1 i-----T-----i O DOWN LIGHT FIXTURE - VARIATION NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE <br /> I LUG <br /> ❑I PB PULLBOX CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND HE SHALL <br /> L LANDING I -�- GROUND CONNECTION <br /> BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, <br /> / AN f J --- WALL MOUNTED DUPLEX GROUNDING RECEPTACLE MH MANHOLE TECHNIQUES, AND SEQUENCES, <br /> (EX.) 200A r MVI I I---- <br /> NEMA 5-20R AT 18" AFF UON 3. ALL DIMENSIONS, EXISTING JOB SITE CONDITIONS, AND SERVICE REQUIRE- <br /> METER I �� I I 1 I ❑F -� FUSIBLE DISCONNECT MENTS SHALL BE VERIFIED BY THE CONTRACTOR BEFORE THE START OF <br /> (CITY OF I I I I [EXISTING' 07 QUADRUPLEX (DOUBLE DUPLEX) GROUNDING SWITCH AS NOTED CONSTRUCTION AND/OR FABRICATION OF MATERIALS. IF DISCREPANCIES <br /> LODI #29121 1 (EX.) I MSN I RECEPTACLE NEMA 5-20R AT 18" AFF UON <br /> 120 24OV, 175A 1 I D SAFETY DISCONNECT ARE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION. <br /> / I / I 1 PANEL I WALL MOUNTED DUPLEX GROUNDING RECEPTACLE SWITCH AS NOTED 4. CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES AND <br /> 10, 3W I 4 C/B I i I � �� I W/ GFI NEMA 5-20R AT 18" AFF UON <br /> I 12P I I I A I WORKMEN TO CLOSE, PATCH AND REPAIR ALL HOLES WHERE ITEMS ARE <br /> Ot 1 #6 CU., TO PANELS "P2": TABLE 250-95 AND ART. 250-79, 1993 N.E.C. I I i L----� ISOLATED GROUND DUPLEX RECEPTACLE COMBINATION MOTOR REMOVED AND PROVIDED OPENINGS AS NECESSARY FOR NEW WORK. <br /> I I I I NEMA 5-20R WALL MOUNTED AT 18" AFF STARTER AND FUSES <br /> I L_--J I 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH NATIONAL <br /> 2 1 #1/0 CU. TO MAIN COLD WATER PIPING WITHIN 5'-0" OF ENTRANCE TO BUILDING. L-----------� 1/2 SWITCHED RECEPTACLE GROUND DUPLEX A AMPS ELECTRICAL CODE (93 EDITION), AND ALL APPLICABLE STATE, COUNTY, <br /> TABLE 250-94, 1993 N.E.C. AND ART. 250-81(a). FLUSH MOUNT FLOOR BOX DUPLEX RECEPTACLE AFF ABOVE FINISHED FLOOR AND LOCAL CODES APPLYING TO THE PROPOSED CONSTRUCTION. IN THE <br /> NEMA 5-20R, GROUNDING TYPE AFG ABOVE FINISHED GRADE EVENT OF CONFLICT BETWEEN THE ABOVE AND THESE PLANS AND <br /> Q 1 #6 CU. 3/4" R.G.S. TO MAIN TELEPHONE BACKBOARD PER 1993 N.E.C. (NEW) AWG AMERICAN WIRE GAGE SPECIFICATIONS, THE MOST RESTRICTIVE SHALL GOVERN. <br /> FLUSH MOUNT FLOOR BOX QUADRUPLEX AUX AUXILIARY <br /> O4 1 1 RECEPTACLE NEMA 5-20R, GROUNDING TYPE 6. CONTRACTOR SHALL VERIFY ALL INFORMATION PERTAINING TO SERVICE <br /> # /0 CU. TO BUILDING REBAR. TABLE 250-94 AND ART. 250-81(c), 1993 N.E.C. BAT BATTERY BY THE UTILITIES AND SHALL INCLUDE THE COST OF ALL WORK BY OR <br /> OVERHEAD FEEDER ® FLUSH MOUNT FBIRD BOARD FOR THEM IN HIS BID. <br /> 0 ONE 20" LENGTH OF #1/0 BARE CU. EMBEDDED IN CONCRETE FOUNDATION WITH MINIMUM <br /> TO POWER CO. P.O.C. BRKR BREAKER 7LOOR BOX TELEPHONE OUTLET . ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND OPERATIONAL <br /> ® <br /> 3" ALL AROUND (UFFER GROUND) PER ART. 250-81(c) OF 1993 N.E.C. AND TABLE FLUSH MOUNT FLOOR BOX DATA OUTLET BLDG BUILDING ELECTRICAL SYSTEM, EXCEPT THAT THE PROVISIONS FOR OWNER-SUPPLIED <br /> 250-94, 1993 N.E.C. LANDING © TIME CLOCK C CONDUIT EQUIPMENT SHALL ONLY BE COMPLETED TO THE POINT INDICATED <br /> CAB CABINET ELSEWHERE ON THE DRAWINGS. <br /> PHOTOCELL CB CIRCUIT BREAKER 8. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFORMITY TO ALL <br /> © COMPRESSION LUGS BOLTED TO PLATE. DRILL TAP FOR REQUIRED NUMBER AND SIZE CLG CEILING LOCAL CODES AND ORDINACES, THE STATE CALIFORNIA ELECTRICAL <br /> OF LUGS PER 1993 N.E.C. ART. 230-75. 400A METER , TELEPHONE OUTLET BOX MOUNTED AT 18" AFF CKT CIRCUIT <br /> M 120/240V UON WITH (1) 3/4" CONDUIT ONLY TO ACCESSIBLE CO SAFETY ORDERS, THE NEC AND ANY ADDITIONAL JURISDICTION RELATING CONDUIT ONLY TO THE WORK. <br /> ELECTRICAL SERVICE NOTES 1o' 3W CEILING SPACE COND CONDENSER <br /> CP CONTROL PANEL 9. IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS <br /> a DATA OUTLET BOX MOUNTED AT ig' AFF UON CU COPPER INDICATED ON THE PLANS AND/OR SPECIFICATIONS OR WITH CODE <br /> WITH (1") 3/4"C. TO CEILING SPACE. <br /> 400AS DS DISCONNECT SWITCH REQUIREMENTS, THE NOTES, SPECIFICATIONS OR CODES WHICH <br /> 1. ALL EQUIPMENT SHALL BE FULLY BUSSED AND BRACED FOR THE INTERRUPTING CURRENT 400AF J J JUNCTION BOX ESTABLISH AND PRESCRIBE THE MORE COMPLETE WORK OR THE <br /> PER POWER COMPANY REQUIREMENTS. 2P O ❑ DWG DRAWING HIGHER STANDARD SHALL PREVAIL. <br /> 2. ALL EQUIPMENT SHALL BE U.L. LISTED AND INSTALLED AS PER LISTING AND LABELING. FLEX CONDUIT <br /> �� EM EMERGENCY 10. EXACT ROUTING OF ALL CONDUITS WITHIN THE EXISTING BUILDING <br /> EMT ELECTRICAL METALIC SHALL BE DETERMINED BY THE CONTRACTOR. ANY COST REQUIRED <br /> 400A BUS 120 24OV, 10, 3W, 42K AIC MIN. 1/2" CONDUIT WITH 2 12 WIRES TUBING <br /> 3. CIRCUIT BREAKERS USED AS SWITCHES SHALL BE LISTED FOR SWITCHING DUTY AND m ® ® ® # TO ROUTE CONDUITS DIFFERENTLY THAN IS SHOWN ON THESE <br /> MARKED "SWD" PER N.E.C. 240-83(d). \ I I I EF EXHAUST FAN DRAWINGS SHALL BE INCURRED BY THE E.C.. <br /> C B ! COB � C BA lTl� HOME-RUN TO PANEL 'A' CIRCUITS 3 AND 5 ES ENERGY SAVING <br /> 2F a / / A-3,5 EC EVAPORATIVE COOLER 11, ALL MATERIALS AND EQUIPMENT SHALL BE DELIVERED TO THE SITE NEW, <br /> 4. ALL CIRCUIT BREAKERS SHALL BE MOLDED CASE THERMAL MAGNETIC AND SERIES RATED (E),EX, EXISTING IN THEIR ORIGINAL UNBROKEN PACKAGES BEARING APPROVAL BY U.L., <br /> WITH MAIN FUSES FOR AVAILABLE SHORT CIRCUIT CURRENT AT SERVICE SWITCHBOARD OL 2P 2P I, TOGGLE SWITCH AT + 44" AFF SUBSCRIPTS EXIST. NEMA, NBFU OR OTHER APPROPRIATE AGENCY, AND INSTALLED PER <br /> PER POWER COMPANY. I` INDICATE THE FOLLOWING: 2-TWO POLE, <br /> 3-THREE WAY, 4-4WAYS, a,b,c-NUMBER GFI GROUND FAULT CIRCUIT THEIR GUIDELINES. <br /> 5. GROUNDING AND GROUND CONTINUITY PER N.E.C. 250. OF SWITCHES INTERRUPTER <br /> G,GND GROUND 12. CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONING ELECTRICAL <br /> 6. SERVICE EQUIPMENT SIZE VARIES WITH MANUFACTURES. VERIFY EXACT EQUIPMENT z SEE GND �M MANUAL DISCONNECT SWITCH WITH THERMAL HPS HIGH PRESSURE SODIUM SYSTEM MEETING THE INTENT OF THESE PLANS AND SPECIFICATIONS. <br /> _ DETAIL OVERLOAD PROTECTION. HTR ALL SYSTEMS SHALL BE IN FOR INSPECTION. <br /> DIMENSION WITH MANUFACTURER. - A IG ISOLATED GROUND <br /> N + LIGHT FIXTURE DESIGNATION. 13. CONTRACTOR SHALL MAINTAIN GROUND CONTINUITY TO EVERY OUTLET <br /> 7, NO HALF-SIZE CIRCUIT BREAKERS SHALL BE USED. N z D 0 64 FIXTURE "A", 64 WATTS. KVA KILOVOLTAMPERS PER N.E.C., TABLE 250-95, 1993. <br /> to KW KILOWATT <br /> 8. ALL CIRCUITS SHALL BE CLEARLY IDENTIFIED AND MARKED ON PANEL CIRCUIT I.D. TAG, v o o `v r M N r CONDUIT COSEALED ABOVE CEILING OR LCL LONG CONTINUOUS LOAD 14. ALL WIRES AND CABLES SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM. <br /> N WALL EXCEPT CONTROL WIRING WHICH SHALL BE #18 THWN. CONDUCTORS <br /> 9. ALL FUSE HOLDERS FOR CURRENT LIMITING FUSES SHALL BE REJECTION TYPE. z <br /> zz zz LTG LIGHTING #10 AWG AND SMALLER SHALL BE SOLID. CONDUCTOR #8 AWG AND <br /> ' � + `z N.O. CONTACTOR -E- EMERGENCY CIRCUIT/CONDUIT <br /> + MDP MAIN DISTRIBUTION PANEL LARGER SHALL BE STRANDED. TYPE OF INSULATION AS NOTED ON <br /> 10. FUSES USED FOR A/C UNITS AND MOTORS TO BE "RK-5" DUAL-ELEMENT TYPE. (MANUAL "ON-OFF" MECH MECHANICAL DRAWINGS AND AS FOLLOWS: <br /> MH METAL HALIDE <br /> --60AS SWITCH ® CASHIER -(E)- EXISTING CIRCUIT/CONDUIT MTD MOUNTED - THHN/THWN INSULATION FOR #4 AWG AND SMALLER. <br /> 11. REFER TO THE FOLLOWING CHART FOR APPROVED SERIES RATED MAIN AND BRANCH F SOAP AREA. SEE - THW OR THHN/THWN INSULATTION FOR #2 AWG AND LARGER. <br /> CONTROL DIAGRAM -- CONDUIT UNDER SLAB OR BELOW GRADE NEC NATIONAL ELECTRICAL - THW USED FOR ALL PANEL FEEDERS AND SERVICE CONDUCTORS. <br /> CIRCUIT BREAKERS FOR 42K A.I.C. MINIMUM (MANUFACTURERS ARE FOR REFERENCE ONLY). AC-1 2P PANEL PANEL ON DWG. "E-2"). CODE - THHN INSULATION TYPE SHALL BE USED WHERE CONDUCTORS <br /> S' "A -OHE- OVERHEAD ELECTRICAL LINE NL NIGHT LIGHT ARE INSTALLED IN CONDUITS EXPOSED TO THE WEATHER, <br /> MAIN NTS NOT TO SCALE <br /> MANUFACTURER BREAKER (MAX.) <br /> BRANCH CIRCUIT BREAKER (AC UNIT) 60A, C/B, 1 -POLE -CT 12x4 CABLE TRAY: 12 INCHES WIDE BY 4 INCHES 15. ALL ELECTRICAL EQUIPMENT SHALL BE ANCHORED FOR SEISMIC LOADING <br /> RATING TYPE (EXTERIOR LTG) (FOODMART) P POLE RESIST A HORIZONTAL FORCE ACTION IN ANY DIRECTION USING THE <br /> C-2 4+ DEEP PC PHOTOCELL FOLLOWING CRITERIA: <br /> SQUARE "D" FC(100AMP 1.1 15A-100A QO/QOB # RECPT. RECEPTACLE FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT <br /> KC(250AMP) 125A-225A QO/QOB 1#8 ISO GND FLUORESCENT LIGHT FIXTURE-VARIATIONS <br /> 6') VOLTAGE ST STAGGERED STRIP <br /> FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT <br /> ( � ❑ ❑ <br /> CHALLENGER CG(10OAMP) 15A-100A CBB/CB8GF REGULATOR ❑ LUMINAIRE FOR FLEXIBLY MOUNTED EQUIPMENT USE 2 TIMES THE ABOVE VALUES. <br /> CJ/CJS(250AMP) 125A-225A CBBH/CE/CFS N.C. CONTACT EOR T TRANSFORMER SIMULTANEOUS VERTICAL FORCE USE 1/3 TIMES HORIZONTAL FORCE. <br /> 12. FUEL SYSTEM EMERGENCY 1:5>< TC TIME CLOCK THIS CRITERIA APPLIES TO EQUIPMENT ON THE FLOOR, WALL, OR ROOF <br /> B PANEL Y THE MANUFACTURER, THE EQUIPMENT <br /> SHUT-OFF TEL. TELEPHONE WITH AN OPERATING WEIGHT OF LESS THAN 1,000 LB.. <br /> COMBINATION RATINGS MARKED ON THE EQUIPMENT B <br /> WHERE CIRCUIT BREAKERS OR FUSES ARE APPLIED COMPLIANCE WITH THE SERIES PF O FLUORESCENT LIGHT FIXTURE TYR TYPICAL 16. CONTRACTOR IS RESPONSIBLE FOR ALL CORING, CUTTING, PATCHING <br /> STRIP LIGHT <br /> ENCLOSURE(S) SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE EQUIPMENT HAS C UL UNDERWRITERS AND REFINISHING OF WALLS AND SURFACES WHENEVER IT IS NECESSARY <br /> BEEN APPLIED WITH A SERIES COMBINATION RATING. THE MARKING SHALL BE READILY WALL MOUNTED FIXTURE LABORATORY PENETRATION. ALL OPENINGS MADE SHALL BE SEALED TO MEET THE <br /> VISIBLE AND STATE "CAUTION - SERIES RATED SYSTEM 42,000 A AVAILABLE. IDENTIFIED LION UNLESS OTHERWISE FIRE RATING AND STRUCTURAL INTEGRITY OF THE PARTICULAR WALL, <br /> REPLACEMENT COMPONENT REQUIRED." (FUEL DISP) WALL PACK FIXTURE NOTED FLOOR, OR CEILING. <br /> EMERGENCY LIGHT FIXTURE, WALL MOUNTED XFMR TRANSFORMER 17. ALL ELECTRICAL FIXTURE AND EQUIPMENT SHALL BE GROUNDED. ALL <br /> --------- EXISTING TO BE REMOVED V VOLTS CONVENIENCE RECEPTACLES SHALL BE GROUNDING TYPE. <br /> SWITCHBOARD ELEVATION 0 FLUORESCENT FIXTURE WITH EMERGENCY BATTERY PACK WH WATER HEATER 18. ELECTRICAL CONTRACTOR SHALL FURNISH TEMPORARY CONSTRUCTION <br /> INDICATES NEW EQUIPMENT inWID WEATHERPROOF POWER WHERE REQUIRED. <br /> THIS DIAGRAM IS BASED ON SQUARE "D" SPEED-D SERVICE SWITCHBOARD AS FOR ® } EXIT LIGHT FIXTURE, SHADED SECTOR WTR WATER <br /> REFERENCE ONLY. DIMENSION VARIES PER MANUFACTURER. INDICATES FACE, DIRECTIONAL ARROWS <br /> AS SHOWN. <br /> SERVICE CONNECTING LOAD CALCULATION SOUTHWEST GROUP REVISIONS --- <br /> N0. DATE BY COMMENTS <br /> _T O - Engineering Consulting Services 1 9-2-g7 RL REVISION PER ULTRAMAR ENGINEER Ultram <br /> a r <br /> LOAD DESCRIPTION KVA OA-N CURRENT 48-N CURRENT 1720 E. Garry Ave. • Suite 232 • Santa Ana • CA 92705 s/oe/97 SJ. ISSUED FOR BID 525 NEST THIRD STREET, HANFORD, CALIFORNIA 93230 <br /> o Tel (714) 851-3185 Fax (714) 851-3016 <br /> o PANEL "A" (INCLUDING "C') 31.6 139 A 124 A ELECTRICAL PLAN <br /> o p 3" HOUSEKEEPING DESIGNED: <br /> CONCRETE PAD PANEL "S 11.9 49 A 50 A PeavEssp <br /> o HVAC UNIT (AC-1) 9.8 41 A 41 A ��o M NA{ R.M.L. <br /> D O LARGEST MOTOR LOAD x 257 <br /> 2.4 10 A 10 A Uw �p� �FFy�D . y DRAWN BY: G.B. <br /> B PLANS PREPARED BY: 401 W. KETTLEMAN LN. & SOUTH LEE AVE. <br /> TOTAL 55,7 239 A 225 A E 014840 A CHECKED BY: A 8e S ENGINEERING LODI, CALIFORNIA <br /> EXP. 6-30-99 R.M.L. _ <br /> TOTAL CONNECTING LOAD = 56 KVA (232 AMP, 120/24OV, 1 0) * �, ,t PROJECT N0. PUNNING ENGINEERING CONSTRUCTION MANAGEMENT SCALE: $,S. <br /> sr`��FCTR��P 3 ASB97141 207 W. ALAMEDA AVENUE, SUIITE 203 NONE # 513 <br /> qTf ORS _ BURBANK, CALIFORNIA 91502 DATE: DRAWING N0. <br /> "OUTDOOR" OF CAUF FILE N0. PHONE: 818-842-3644 FAx: 818-842-3760 7-30-97 E-1 <br /> OF <br /> 97141 E1 n <br />