Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN- Page 1 of 2) <br /> TYPE OF ACTION L NEW PLAN ❑ 2.CHANGE OF INFORMATION 4�1 <br /> PLAN TYPE ❑ I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 4%2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S) t�l�5 r1 L 7A/I L S <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) Ay SARP _ _ 1 <br /> BUSINESS NAME(Same as FACILITY NAME) TOYA�z ) 3. <br /> BUSINESS SITE ADDRESS VZ,() 0 A ./i 103. CITY LO j Ioa. <br /> H.EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 2632 2634 2638 2641 , <br /> MONITORING EQUIPMENT IS SERVICED L ANNUALLY ❑ 99.OTHER490.3. <br /> (Specify): 490.36 <br /> III. ONIT G LOCATIONS <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. .SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)4904 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490.5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL A ARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 49M <br /> PANEL MANUFACTURER: ode {Zta 'F 490-3 MODEL#: 'T'L 496s <br /> LEAK SENSOR MANUFACTURER: �/ � MODEL#(S): 79`13 O - 490'1° <br /> '❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 1 49o-1I <br /> _PANEL MANUFACTURER: 4%-IZ MODEL#: 49°'13 <br /> IN-TANK PROBE MANUFACTURER: 490'14 MODEL#(S): 49ad5 <br /> LEAK TEST FREQUENCY: [Ia.CONTINUOUS Elb.DAILY/NIGHTLY ❑ c.WEEKLY 49616 <br /> _ ❑ d.MONTHLY _ _ ❑ e.OTHER(Specify): 490'13 <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. 49618 <br /> g.p.h. g.p.h. ❑ c.OTHER(Specify} 49619 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 49620 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 49°-21 <br /> [_190-22 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490-23 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490'24 <br /> 490-25 <br /> ❑99.OTHER (Specify): 49626 <br /> 49627 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 4�28 <br /> ISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 4%-29 <br /> PANEL MANUFACTURER: e - fJ490"10 i MODEL#: T 490x1 <br /> LEAK SENSOR MANUFACTURER: V 49632 MODEL#(S):7 3 - Q 49633 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. a YES ❑b.NO 49x34 <br /> AILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. a.YES ❑b.NO 490'35 <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TES SAND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED(23 CCR 2636 49°36 <br /> MLLDMANUFACTURER(S):1 111 TAC 49033 MODEL#(S):L ��VO PXIV -D 4963e <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636)or 49639 <br /> ELLD M_ANUFACTURENS) 4904Q MODEL#(S): 49041 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49044 <br /> ❑ 4.PIPE INTEGRITY TESTING49645 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49646490.43 <br /> ❑ 5.VISUAL PIPE MONITORING. <br /> FREQUENCY E] a.DAILY [Ib.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 4W49 <br /> -Allowed for m9Nbn duilnnedemcmcv R..w fuel piping odv im HSC 125281.5(b)(3) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(a)(3)1• 490-50 <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 <br /> ❑ 99.OTHER(Specify) 49652 <br /> 490.53 <br /> UPCF UST-D(12/2007)1/4 <br />