My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0231906
>
COMPLIANCE INFO 2001-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2021 1:08:13 PM
Creation date
11/5/2018 3:42:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2010
RECORD_ID
PR0231906
PE
2361
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
01
SITE_LOCATION
420 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\420\PR0231906\COMPLIANCE INFO 2001-2010.PDF
QuestysFileName
COMPLIANCE INFO 2001-2010
QuestysRecordDate
5/19/2017 11:33:18 PM
QuestysRecordID
3391364
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form i intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts f om tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility N e: TOKAY SHELL Date of Testing: 1/5/10 <br />Facility Adc ress: 420 W. KETTLEMAN LN. LODI, CA 95240 <br />Facility Cor tact: JAS Phone: 209-369-2790 <br />Date LocalAgency Was Notified of Testing :12/29/09 <br />Name of Lo al Agency Inspector (ifpresent during testing): <br />2. TESTING CONTRACTOR INFORMATION <br />Company IN ame: AFFORDA TEST 4162 "d Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician onducting Test: ❑ Lyle D. Nimmo ® Zane A. Nimmo ❑ David A. Winkler ❑ Felix G. Ramirez <br />5249115 -UT 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials : ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipe tent Used: TAPE MEASURE, H2O <br />Equipment Resolution: 1/16" <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />1 87 <br />2 91 <br />3 100 OCT <br />4 DIESEL / <br />WASTE OIL <br />Bucket Inst Ilation Type: <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in <br />SumpSum <br />® Direct Bury <br />❑ Contained in <br />Bucket Diameter: <br />1 I <br />11 <br />I I <br />1 I 1 1 <br />Bucket Depth: <br />12 <br />14 <br />13 <br />13 --- I I <br />Wait time between applying <br />vacuum/wa er and start of test: <br />__ <br />Test Start Time (T[): <br />930 <br />930 <br />930 <br />930 --- 1200 <br />Initial Reading (Ri): <br />11 1/8 <br />125/8 <br />12 1/2 <br />12 1/4 --- 105/8 <br />Test End Time (TF): <br />1030 <br />1030 <br />1030 <br />1030 --- 1300 <br />Final Reading (RF): <br />11 1/8 <br />125/8 <br />12 1/2 <br />12 1/4 --- 10 5/8 <br />Test Durati n(TF —Ti): <br />HR <br />HR <br />HR <br />HR --- HR <br />Change in eading(RF -Ri): <br />0 <br />0 <br />1 0 <br />0 0 <br />Pass/Fail T reshold or <br />Criteria: <br />PASS <br />Test Resu t <br />Z Pass ❑ Fail <br />® Pass ❑ Fail <br />I Z Pass ❑ Fail <br />1 ® Pass ❑ Fail <br />Commenks — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />1 hereby ce tify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Signature: e Date: 1-5-10 <br />State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be njore stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.