Laserfiche WebLink
HAZARDOUS AREA NOTES SITE PLAN NOTES <br /> N.E.C. <br /> FAA i' I <br /> TYPICAL N.F.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK -- FILL OPENING) EXISTING PRODUCT DISPENSER TO BE REPROVED. - <br /> A EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> Any pit, box, or space below grade level, ony part of which is within the Division 1 " <br /> or 2 classified location. ( 2 NEW MULTI—PRODUCT DISPENSER "MPD. SEE TANK DRAWINGS. <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> Up to 18 inches above grade level within a horizontal radius of 10 feet from a loose 3 NEW 3/4" CONDUIT TO NEW "MPD." INSTALL (4) BELDEN 66760 <br /> fill connection and within a horizontal radius of 5 feet from a tight fill connection. CABLE. FOR LEAK DETECTION, <br /> D TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK — VENT—DISCHARGING UPWARD) <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: NEW 1" CONDUIT TO NEW "MPD." INSTALL POWER WIRES AND <br /> Within 3 feet of open end of vent, extending in all directions. DATA CABLES PER MANUFACTURER'S SPECIFCIATIONS, <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> Space between 3 feet and 5 feet of open end of vent, extending in all directions. " <br /> NEW 1 CONDUIT TO NEW "MPD." INSTALL (6) #16 TW TWISTED PAIR <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR) INDIVIDUALLY SHIELDED CABLES TO SALES COUNTER, FOR INTERCOMS <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: IN DISPENSERS. <br /> Any pit, box, or space below grade level if any port is within a horizontal distance <br /> of 10 feet from any edge of pump. <br /> EXTENT OF CLASS 1, GROUP D. DIVISION 2 LOCATION: 6 NEW 1" CONDUIT WITH PULL. LINE TO PANEL AREA. SPARE FOR FUTURE <br /> Within 3 feet of any edge of pump, extending in all directions. Also up to 18 inches USE. L? e <br /> above grade level within 10 feet horizontally from any edge of pump. <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE — PITS) ° EXISTING P.I.C. UNITS TO REMAIN. RETAIN EXISTING POWER AND DATA a <br /> D EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: WIRING. FIELD VERIFY. REPAIR ANY CIRCUITING DAMAGED DURING <br /> Any pit, box, or space below grade level, any part of which is within the Division 1 CONSTRUCTION. <br /> or 2 classified location. <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE — DISPENSER) 66D EXISTING STORAGE TANKS TO REMAIN. s <br /> E EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> Space classification inside the dispenser enclosure is covered in ANSI/UL 87, <br /> "Power Operated Dispensing Devices for Petroleum Products." NEW 1" CONDUIT WITH (6) BELDEN 66760 CABLES TO TLS-350 PANEL. <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE — DISPENSER) 10 NEW 3/4" CONDUIT WITH (6) BELDEN 66760 CABLES, <br /> F EXTENT OF CLASS 1, GROUP D. DIVISION 2 LOCATION: <br /> Within 18 inches horizontally in all directions extending to grade from (1) the 11 NEW 3/4" CONDUIT WITH (4) BELDEN 66760 CABLES. <br /> dispenser enclosure or (2) that portion of the dispenser enclosure containing <br /> liquid handling com onents. Space classification inside the dispenser enclosure <br /> is covered in ANSI�UL 87, "Power Operated Dispensing Devices for Petroleum 12 NEW 3/4°' CONDUIT WITH (2) BELDEN 66760 CABLES. <br /> Products." <br /> I <br /> p _ TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE -- OUTDOOR) 13 NEW 3/4" CONDUIT FOR LEAK DETECTION, INSTALL (4) BELDEN 66760 <br /> G <br /> EXTENT OF CLASS 1, GROUP D. DOASION 2 LOCATION: CABLES. FOR LEAK DETECTION, <br /> Lip to 18 inches above grade level within 20 feet horizontally of any edge of enclosure. <br /> 14 NEW 3/4" CONDUIT. INSTALL (3) BELDEN 66760 CABLES. <br /> NEW 3/4" CONDUIT. INSTALL (2) BELDEN 66760 CABLES. <br /> 36 --- a --�- -� - " 16 NEW 3/4" CONDUIT. INSTALL (1) BELDEN 66760 CABLE. <br /> 17 NEW 3/4" CONDUIT WITH (3) #10 PLUS (1) #10 GROUND TO PANEL "F" <br /> a _ - (VIA 'TURBINE CONTACTORS). <br /> 16 NEW 3/4" CONDUIT WITH PULL LINE TO PANEL AREA. SPARE FOR <br /> FUTURE USE. <br /> 19 NEW 3/4" CONDUIT WITH (4) BELDEN 66760 CABLES TO TLS-350 PANEL. <br /> 17 > 20 NEW 3/4" CONDUIT WITH (3) BELDEN 66760 CABLES. <br /> a <br /> 23 25 21 NEW 3/4" CONDUIT WITH (1) BELDEN 66760 CABLE. <br /> 13 a „22 NEW OVERFILL ALARM AND ACKNOWLEDGEMENT SWITCH. SEE DETAIL_ <br /> _ _ --- � - - - -- O 5 ON SHEET E2-3. <br /> CK So _ 2Q 22 34 31 __ _ 34 23 NEW 3/4" CONDUIT WITH (5) #12 PLUS (1) #12 GROUND. CKT F-19. <br /> 24 I 32 33 24 EXISTING EMERGENCY SHUT--OFF SWITCH TO REMAIN, WIRE PER DIAGRAM <br /> -�' 10 go® o'?g � 17 3 ON SHEET E2--2. <br /> U 25 EXISTING COUNTER MOUNTED EMERGENCY SHUT-OFF SWITCH. PROVIDE <br /> 15 Y $018D [ a _ Q RESET SWITCH AND WIRE SYSTEM PER DIAGRAM ON SHEET E2--2. CL <br /> 26 NEW TOKHEIM SITE CONTROLLER AND DISTRIBUTION BOX. <br /> 17 0 <br /> 016 --- 1 I 7 f 39 27 EXISTING RONAN LEAK DETECTION SYSTEM 'TO BE REMOVED AND REPLACED <br /> �CDa _ -- <br /> 1 ---d- 40 WITH NEW VEEDERROOT TLS--350 SYSTEM. CIRCUIT AS SHOWN. <br /> CD <br /> I-- -- __ — - 4 26 NEW PANEL "F.°" SEE SHEET ES1-2. <br /> 29 EXISTING "ALLIED BOX" S.A.M. AND P.I,C INTERFACE BOX TO REMAIN. <br /> 0 <br /> 35 (° ALL NEW CONDUITS FROM PANEL AND PUMP CONTROLS TO FUEL ISLANDS <br /> 42 3OI1 (TYP OF 6) AND FUEL TANKS SHALL_ BE RIGID GALVANIZED STEEL. PVC COATED <br /> 6 39 7 THROUGHOUT. <br /> -4------ 2 (TYP OF 4) amnlown <br /> 40 - 0 ALL CONDUITS FROM FUEL ISLANDS AND FUEL TANKS SHALL BE SEALED <br /> 0 � � � �� _J31 D EAT AT BOTH ENDS WITH CROUSE HINDS TYPE "EYS" FITTINGS. SEE <br /> ( n DETAIL A, SHEET E-2. <br /> 32 ALL ELECTRICAL WORK WI'T'HIN DISPENSERS AND FUEL PUMPS <br /> UNDERGROUND BELOW CLASS 1 DIVISION 2 LOCATIONS SHALL CONFORM <br /> TO CLASS 1 DIVISION 1 LOCATION REQUIREMENTS. <br /> 33 CONTRACTOR TO VERIFY THAT ALL EXISTING WIRING IN HAZARDOUS <br /> K' ETTLEMAN LANE AREAS MEET HAZARDOUS AREA REQUIREMENTS. UPGRADE IF REQUIRED, <br /> 34 EXISTING CANOPY LIGHTS, AREA LIGHTS, SIGNS, AND VIDEO CIRCUITING 'TO <br /> REMAIN. CONTRACTOR TO REPAIR DAMAGED CIRCUITS AS REQUIRED. <br /> 35 PROVIDE STATIC GROUND PER DETAIL 2, SHEET E-4. <br /> 36 EXISTING MAIN SERVICE SWITCHBOARD. <br /> 7 4" CONDUIT WITH PULL LINE TO TLS-350 MONITOR PANEL, STUB <br /> CONDUIT UP AT VENT RISLR SUPPORT MINIMUM 4" AEI CRA09 E 00 UJ <br /> AND OAP, FOR FUtURr USE, <br /> i 36 1" CONDUIT FROM DISPENSER TO DISPENSER WITH (4) #16 TWISTED PAIR <br /> CABLES ROUTED TO SALES COUNTER, FOR INTERCOMS IN DISPENSERS. <br /> Ln <br /> 39 1" CONDUIT FROM DISPENSER TO DISPENSER WITH (2) #16 TWISTED PAIR <br /> CABLES ROUTED TO SALES COUNTER, FOR INTERCOMS IN DISPENSERS. <br /> 4O 1" CONDUIT FROM DISPENSER TO DISPENSER. SPARE FOR FUTURE USE. <br /> 4 3/4" CONDUIT FROM DISPENSER -TO DISPENSER, WITH (2) BELDEN <br /> #66760 CABLES, FOR LEAK DETECTION. <br /> C4 D 3/4" CONDUIT FROM DISPENSER TO DISPENSER, WITH (1) BELDEN owns <br /> #66760 CABLE. FOR LEAK DETECTION, <br /> 43 NEW "POWER SOLUTIONS" DISPENSER MANAGER. SEF SHEETS E2-2 <br /> AND E2--5, <br /> �C YJ 0ROUP INC <br /> ARCHITECTURE-ENGINEERING- <br /> -ENMONMENTAL SERVICES <br /> 1201 S. BEACH BLVD. STE. 207 <br /> LA HABRA, CA 90631 <br /> (562) 9026023 <br /> JOHN W. JOHNSON, ARCHITECT <br /> w <br /> consultant job# <br /> 5314.10 <br /> master release date <br /> O. PP WEST COAST PRODUCTS RASTER REVISIONS exeprojectto drawemaster <br /> � � drag drawn by <br /> NO. DATE REVISIONS RX PROJECT RELEASENORTH <br /> a 1 8/26/02 REVISED PER DID ADDENDUM #1 � � CAM _ <br /> PERMIT FilenameFACO2076D1 1 <br /> Facility/Project <br /> t 0 20 40 60 BID <br /> 02076 <br /> CONST® sl�e eFn m <br /> _._.__.._ <br /> ( <br /> IN FEET ) <br /> 1 inch =20 ft. _ ____ __ _� - _--_-�- AS-BUILT <br />