My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:48:32 PM
Creation date
11/5/2018 4:42:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Apr 18 2018 1435 HP Fax page 2 <br /> UNDERGROUND STORAGE TANK <br /> DESIGNATED UNDERGROUND STORAGE TANK OPERATOR VISUAL INSPECTION REPORT ( Page 2of 2 ) <br /> VII . INSPECTION HISTORY Y N <br /> Has each follow-up action of section III from the previous inspection been completed appropriately? ® ❑ <br /> ' <br /> Attach documentation ve n a pro nreate service to this ort- <br /> Vlll . ALARM HISTORY <br /> Attach a copy of the alarm history reportflog to this report. Y N NA <br /> Is the monitoring system powered pn and in proper operating mode? I@ ❑ ❑ <br /> Has each leak detection alarm since the previous inspection been responded to appropriately? ® 13 11(Attach documentation verifying appropriate service to this report.) <br /> Have all containment sumps , that have had a leak detection alarm since the previous inspection , been responded to by a qualified UST ® 11 11service technician? <br /> List below in section DC, all containment sumps that have had a leak detection alarm since the previous inspection and have not been <br /> responded to by a qualified UST servicb technician. Containment sumps fisted below require a visual inspection for damage, water, debris, <br /> hazardous substance and pronr sensor location. The results of the visual in action must be recorded to section /X <br /> IX. UNDERGROUND STORAGE TANK SYSTEM INSPECTION <br /> Is the containment sump free of damage, water, debris, and hazardous substance? <br /> Containment Sump ID Y N Containment Sump ID Y N <br /> T1 : Regular- STP ❑ ❑ El El <br /> Premium- STP ❑ ❑ ❑ ❑ <br /> T3: Diesel- STP ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> Are all sensors in containment sumps inspected located to detect a leak at the earliest opportunity? ❑ ❑ <br /> Is the spill container free of damage , water, debris, and hazardous substance? <br /> TANK ID T1 : Regular ® ❑ T3 : Diesel ® � Q <br /> T2 : Premium ® ❑ ❑ [t ; <br /> Is the fill pipe free of obstructions? <br /> TANK ID T1 : Regular ® ❑ T3: Diesel ® ❑ <br /> T2 : Premium ® ❑ ❑ p <br /> Is the fill cap securely on the fin pipe? <br /> TANK ID T1 : Regular ® ❑ T3 : Oiesel ® ❑ <br /> T2: Premium ® ❑ p ❑ <br /> Is the urcteredispenser containment free of damage, water, debris, and hazardous substance? <br /> Under-dispenser Containment ID Y I N Under-dispenser Containment ID <br /> Y N NAI <br /> 1 /2 ® <br /> El 11 ❑ ❑ <br /> 3/4 ® ❑ ❑ 11 ❑ <br /> 5/6 ® ❑ ❑ ❑ ❑ 117/8 ® ❑ ❑ ❑ ❑ ❑ <br /> 9/ 10 01 01 ❑ ❑ or ❑ <br /> 11 !12 ® ❑ ❑ ❑ ❑ ❑ <br /> Are all sensors in under-dispenser containment located to detect a leak at the earliest opportunity? ® ❑ 1 d <br /> X . TESTING AND MAINTENANCE Y N NA DATE LAST <br /> Has the monitoring system certification been completed within the past 12 months? PERFORMED <br /> 101 El 12/11118 <br /> Has the spill container testing been completed within the past 12 months? 10 ❑ 12/11 /18 <br /> Has the .overfill prevention equipment inspection been completed within the past 36 months? ® 11 EI 12/11 /18 <br /> Has the secondary containment testing been completed within the past 36 months? ® ❑ ❑ 1 /24/18 <br /> Has the tank tightness testing been completed within required timeframes? ❑ ❑ ❑ <br /> Has the line tightness testing been completed within the required timeframes? ❑ ❑ ❑ <br /> Other required testing / maintenance was completed within rwuired timeframe . List testfmaintenance items below. <br /> Test / Maintenance: Air Quality test <br /> 01 ❑ 12/11 /18 <br /> Test / Maintenance: ❑ ❑ <br /> Test / Maintenance: ❑ ❑ <br /> Test / Maintenance: ❑ ❑ <br /> Test / Maintenance: ❑ ❑ <br /> I I <br /> Test / Maintenance: ❑ ❑ <br /> 1 r- <br /> XI . FACILITY EMPLOYEE TRAINING I Y N <br /> Have all individuals performing facility employee duties received the required facility employee training within the past 12 months? ® ❑ <br /> If the facility has more comoonente than this form wcnmm^4. #&)s, additional copies of this page may be attached. <br /> Received Time Dec , 20 . 20 .18 1 : 10P9 No , 4501 <br /> Y = Yes. N = Na NA = �t Aoolicahle. 10 = Iderthficabon <br />
The URL can be used to link to this page
Your browser does not support the video tag.