My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:48:32 PM
Creation date
11/5/2018 4:42:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> SMARTSENSOR SETUP <br /> s 1 :VFM 1-2 <br /> LIQUID SENSOR ALMS CATEGORY AIR FLOW METER <br /> L 1 :FUEL ALARM <br /> L 2:FUEL ALARM s 2:VFM 3-4 <br /> L I :SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> ( L 2:SENSOR OUT ALARM <br /> ff L 1 :SHORT ALARM s 3:VFM 5-6 <br /> L 2:SHORT ALARM CATEGORY AIR FLOW METER <br /> i <br /> ISD SITE ALARMS s 4:VFN1 7-8 <br /> ISD GROSS PRES FAIL CATEGORY AIR FLOW METER <br /> LIQUID SENSOR SETUP _ ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL s 5:VFM 9-10 <br /> L 1 :REG ANN ISD VP PRES FAIL CATEGORY AIR FLOW METER <br /> TRI-STATE (SINGLE FLOAT) ISD VP STATUS FAIL <br /> CATEGORY : ANNULAR SPACE s 6:VFM 11-12 <br /> ISD HOSE ALARMS CATEGORY AIR FLOW METER <br /> ALL:FLOW COLLECT FAIL <br /> s 7:CANISTER <br /> L 2:REG STP SUMP R 2:SUPREME STP CATEGORY VAPOR VALVE <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> CATEGORY : STP SUMP STANDARD s 8:ATN1 <br /> NORMALLY CLOSED CATEGORY ATM P SENSOR <br /> TANK #: 2 s16:PRESSURE SENSOR <br /> L 3:SUPREME ANN <br /> TRI-STATE (SINGLE FLOAT) CATEGORY VAPOR PRESSURE <br /> CATEGORY : ANNULAR SPACE LIQUID SENSOR ALMS <br /> L 1 :FUEL ALARM <br /> L 4:FUEL ALARM <br /> L 4:SUFREME STP SUMP L 3:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 4:SENSOR OUT ALARM <br /> CATEGORY : STP SUMP L 3:SHORT ALARM <br /> L 4:SHORT ALARM <br /> L 5:DIESEL ANN ISD SITE ALARMS <br /> TRI-STATE (SINGLE FLOAT) ISD GROSS PRES FAIL' <br /> CATEGORY : ANNULAR SPACE ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> ISD VP PRES FAIL <br /> ISD VP STATUS FAIL EVR/ISD SETUP <br /> L 6:DIESEL STP SUMP ISD HOSE ALARMS <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : STP SUMP ALL:FLOW COLLECT FAIL <br /> EVR TYPE: BALANCE <br /> R 3:DIESEL <br /> TYPE: BALANCE NOZZLE TYPE <br /> STANDARD VST <br /> NORMALLY CLOSED <br /> VAPOR PROCESSOR TYPE <br /> TANK #: 3 VEEDER-ROOT POLISHER <br /> LIQUID SENSOR ALMS ANALYSIS TIMES <br /> L 5:FUEL ALARM TIME: 10:00 AM <br /> L 6:FUEL ALARM DELAY MINUTES: 1 <br /> OUTPUT RELAY SETUP L 5:SENSOR OUT ALARM <br /> - - - _ _ - _ - - - - - L 6:SENSOR OUT ALARM <br /> L 5:SHORT ALARM ACCEPT HIGH ORVR: <br /> R 1 :REG STP L 6:SHORT ALARM ENABLED <br /> TYPE: <br /> STANDARD ISD HOSE TABLE <br /> NORMALLY CLOSED ID FP FL HL AA RR <br /> ------------------------ <br /> TANK #: 1 01 00 01 02 01 02 <br /> 02 01 02 02 01 02 <br /> 03 02 03 02 02 02 <br /> 04 03 04 02 02 02 <br /> 05 04 05 02 03 02 <br /> 06 05 06 02 03 02 <br /> 07 06 07 02 04 02 <br /> 08 07 08 02 04 02 <br /> 09 08 09 02 05 02 <br /> 10 09 10 02 05 02 <br /> i � I .n 11 w nA 02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.