My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:48:32 PM
Creation date
11/5/2018 4:42:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA` - IJ Q A Q U I 1IAYI, Environmental Health Department <br /> __.COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LATHROP GAS& FOOD INC 140 E LATHROP RD, LATHROP December 11, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS It,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 309 CCR 2636(0(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The floats and chains in dispensers 11112, 516, 718, and 314 for the 87 product line failed to activate an audible and <br /> visual alarm when tested to ensure continuous monitoring of the tank system. All monitoring equipment shall be <br /> maintained to activate an addible and visual alarm or stop the flow of product at the dispenser when it detects a <br /> leak. The technician adjusted and cleaned the floats and chains in the above dispensers. He retested the floats and <br /> chain and verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the dispenser 11112 and 9110 under dispenser containment sump. If water could enter into <br /> the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. Immediately <br /> remove this liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, and manage it <br /> accordingly. Ensure that the under dispenser containment in dispenser 11112 and 9110 is maintained free of liquid. <br /> Technician removed liquid from the under dispenser containment from dispenser 9110 and 11112 after he tested the <br /> floats and chains. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 111012018. <br /> Documents reviewed: Monitoring system certification report, Secondary containment testing report, Employee <br /> training log. Designated operator monthly reports, alarm history and set up, monitoring plans, response plan, <br /> and financial responsibility, letter from chief financial officer, current permit on site. <br /> Documents received: Return to compliance certification. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0006943 PRO505657 SC001 12111!2017 <br /> EHD 23-01 Rev.09122116 Page 5 of 6 Underground Storage Tank Program 01R <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.