My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:48:32 PM
Creation date
11/5/2018 4:42:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI C FV EE D <br /> MONITORING SYSTEM CERTIFICATION PF(" `, 7 2017 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of <br /> Regulations ENVIRONMENTAL HEALTH <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared WDEPARTMENT <br /> each monitoring system control panel by the technician who perfomis the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A General lrrfonnation <br /> Facility <br /> Name: LATHROP FOOD AND GAS Bldg.No.: <br /> Site <br /> Address: 140 E LATHROP RD City: LATHROP Zip: 96330 <br /> Facility Contact <br /> Person: JESSIE Contact Phone No.: (209)814-3730 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 360 Date of Testing/Servicing: 12-11-17 <br /> B. Inventory of Equipment TestedlCedified <br /> Check the appropriate boxes to indicatespecific equipment ins ectedlserviced: <br /> TanklD: 87 TanklD: 91 <br /> S In-Tank Gauging Probe. Model: MAG 1 S In-Tank Gauging Probe. Model: MAG 1 <br /> ❑ Annular Space or Vault Sensor. Model: 420 S Annular Space or Vault Sensor. Model: 420 <br /> S Piping Sump/Trench Sensor(s). Model: 208 S Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensoria). Model: <br /> S Mechanical Line Leak Detector. Model: 90 LD 2000 S Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: FLAPPER S Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). Cl Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL TanklD: <br /> S In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> S Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> S Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Senwgs). Model: ❑ Fill Sump Sensor(s). Model: <br /> S Mechanical Line Leak Detector. Model: 99 LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> S Tank Overfill/High-Level Sensor. Model: FLAPPER ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3.4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> S Shear Valve(s). S Shear Valve(s). <br /> S Dispenser Containment Float(s)and Chain(s). S Dispenser Containment Float(s)and Chain(s). <br /> DlspenserlD: 5-6 DispenserlD: 7.8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> S Shear Valve(s). S Shear Valve(s). <br /> S Dispenser Containment Floats)and Chain(s). S Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11.12 <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ® Shear Valve(s). S Shear Valve(s). <br /> ® Dispenser Containment Floats)and Chain(s). S Dispenser Containment Float(s)and Chain(s). <br /> `If the facility contains more tanks or dispensers,copy this forth. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: �y— <br /> tm - <br /> Cercation No.: 5273934-UT License No: A 0&1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n0 STREET GALT CA 95632 Date or Testing/Servicing: 12-11-17 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.