INSTALL_2003 TANK TOP UPGRADE PLAN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
INSTALL_2003 TANK TOP UPGRADE PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:29 PM
Creation date
11/5/2018 4:45:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003 TANK TOP UPGRADE PLAN
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\TANK TOP UPGRADE PLAN 2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U � <br /> J � � <br /> DISPENSER Z .� <br /> 1f1 U c0 Q <br /> PRODUCT SHEAR VALVE cv (p 1L <br /> W/ FU515LE LINK / Q 62" <br /> (VAPOR SHEAR VALVE STABILIZER BAR BY Z 1- i r- <br /> W/ FUSIBLE LINK, SIM) SUMP MNFR V �J X Z N <br /> Z <br /> EXPLOSION PROOF "J" ------- ISLAND / DRIVE SLAB ! \ ��V�� ~ I ZO <br /> BOX W/ SEAL-OFFS, TYP. � <br /> 9 I f, - ,� � Um� <br /> DISPENSER PAN s ° �/ �/ /\ \� \ �I\ 04 BARS, 6' MIN., TYPICAL N <br /> 5UMP PROBE <br /> LISTED FLEX CONNECTORS - — T� �j — \� -� — - cN <br /> PHASE I DRYBREAK / <br /> — CONDUIT BOOT / SEAL, TYP. MANHOLE <br /> DBL. WALL <br /> PRODUCT, VAPOR <br /> PIPING, SLOPE <br /> TO TANK DISPENSER SUMP <br /> BULKHEAD FITTING, TYP, -- SECONDARY TERMINATION FITTING W <br /> W/NPT TAP VOR TEST PORT ASSEMBLY / �� I } I � %D <br /> »w , ,_✓ 4', TYPICAL z W <br /> INSTALL ALL EQUIPMENT m u} <br /> PRODUCT FILL WPER MRREQUIREMENTS Q O u_ <br /> MANHOLE , QLL <br /> w w _ <br /> DISPENSER PAN DETAIL O o ° m ro w u <br /> N.T.S. - SOME EXAGGERATION FOR CLARITY \� �� �� - TOE OF CROWN W = W N ' IT- <br /> CROWN_� SLAB P/12" � V 0 r c� � <br /> X AT MANWAYS '� Q_ (j) <br /> "FLAT" GONG. TOP, <br /> SMOOTH FINISH <br /> WQ <br /> 6" STEELo <br /> W <br /> TUBE, GONG. FILLED E z <br /> U <br /> j <br /> PAINT J <br /> FILL ASSEMBLY SYSTEM INCLUDES: <br /> 5 GAL, FILL CONTAINMENT MANHOLE <br /> " (OPW 1-2100 SERIES) W/ FILL CAP (634TT-ER) A <br /> TOP SEAL ADAPTOR (61SALP-EVR), TYP. W <br /> 18"4, GONG. FTG. 5 GAL FILL CONTAINMENT MANHOLE <br /> 11�I 1 _ (OPW 1-2100 SERIES) W/ FILL CAP (Ill1T-EVR) < J W <br /> z 1'L�II- TOP SEAL ADAPTOR ((o1V5A-ER), TYLL <br /> T- I-II II'r Q <br /> 1ju o <br /> �FI�EL ISL�WND BOLLARD <br /> 3 SCALE: 1/2" I'-0° <br /> 4"0 BLACK ION RISERS INSTALL NEW 42"b SUMP <br /> TYP., W/ NIPPLES AND ONTO NEW SUMP COLLAR <br /> ADAPTOR AS RII f >_ <br /> (PRODUCT INCLUDES OPW FS4-400 W Q H <br /> FACE AL ADAPTOR AND OPW M Z <br /> 61JSK-EVRSJACK SCREW DROP TUBE � . '.I SEAL CONDUIT PENETRATIONS Q o o <br /> LOCK DOWN DEVICES) W/ ENVIRON ENTRY FITTING y® � T Z <br /> _ <br /> 3'-& ' M.N. 3'-6" MIN. __ _ SUMP PROBE, TYP. r 6) <br /> BOLLARD, TYPICAL - -- --- VEEDER-ROOT SERIES 1943 <br /> — — — — PROVIDE 5% SLOPE AWAY IL p <br /> CANOPY COLUMN, TYP. -'1 FROM DISPENSERS, FOR S.5" J O '7 Z <br /> x 'AROUND DISP., TYP. N � z W <br /> 1- TANK MNFR TO INSTALL NEW Q <br /> _ SUMP COLLAR J <br /> DISP. I � <br /> �L <br /> 4 x 0f --J--�-- <br /> F �LEALEVE� <br /> AR€A, T,YP- OVERFILL PREVENTION VALVE <br /> - - - - (OPW 6160-EvR SERIES) <br /> SET FOR SHUT-OFF AT 95% <br /> OF TANK CAPACITY, MAX. <br /> CONFIRM 15LAND LAYOUT W/ NOTE: LAYOUT A55UME5 USE G° A 405" x 24" WIDE <br /> OWNER SUPPLIED DISPENSERS DISPENSER, W/ CARDREADER RECESSED (11/2" FROM THE <br /> BASE. ADJUSTMENTS ARE APPROPRIATE VOR REQUIRED <br /> FOR A DIFFERENT DISPENSER OR COLUMN WIDTH. <br /> CONFIRM EQUIPMENT AND CANOPY CONFIGURATION <br /> BEFORE START OF CONSTRUCTION. <br /> W <br /> F <br /> Q <br /> CARD-READING DEVICES (ANNOTATED C.B.C. 11C EXCERPTS) � <br /> WHERE ONLY ONE CARD-READING DEVICE IS 2. AN ACGE5515LE PATH O' TRAVEL SHALL BE <br /> INSTALLED FOR USE WITH ANY TYPE OF MOTOR FUEL, PROVIDED TO THE BASE OF ALL FUEL DISPENSERS <br /> IT SHALL MEET THE REQUIRED FEATURES (LISTED). REQUIRED TO MEET (THESE PROVISIONS). SUCH FUEL y y o <br /> WHEN MORE THAN ONE CARD-READING LOCATION IS DISPENSERS SHALL BE MOUNTED ON THE I i at <br /> AVAILABLE FOR A SPECIFIC TYPE OF MOTOR FUEL, A ACCESSIBLE LEVEL AREA. , TYP. w w <br /> m w g x <br /> MINIMUM OF 45' FIELD CUT <br /> TWO FOR THAT TYPE SHALL HAVE THE J LL V U w U <br /> ACCESSIBLE FEATURES (LISTED). 3. AN ACCESSIBLE LEVEL AREA SHALL BEw '�E_E <br /> PROVIDED WHICH 15 MINIMALLY 30 INCHES BY 45 <br /> CARD-READING DEVOF5 AT MOTOR VEHICLE FUEL INCHES LEVEL AND CLEAR THIS AREA SHALL BE TANK STRIKER PLATE BY TANK w <br /> FACILITIES SHALL BE ACCES51BLE BY COMPLYING PROVIDED WITHIN 10 ING4E5 IN PLAN VIEW OF THE MANUFACTURER (TYP) UNDER 1{,1 J m� yaw 0 <br /> WITH ONLY THE FOLLOWING: FACE OF THE CONTROLS AND SHALL BE ALL TANK OPENINGS. F I- <br /> UNOBSTRUCTED BY ANY FEATURES, EXCEPT PUMP F- O Q a Jz u <br /> I. THE HIGHEST OPERABLE PART OF EACH PRIMARY NOZZLES AND H05E6, WI-H THE LONG SIDE OF THIS W <br /> OR ALTERNATE CARD READER SHALL BE NO SPACE PARALLEL TO AND CENTERED (PLUS OR .9 lLW <br /> MORE THAN 54 INCHES MEASURED FROM THE BASE MINUS 9 INCHES) WITH THE FACE OF THE I• '-w o <br /> OF THE FUEL DISPENSER. WHERE CARD READERS CARD-READER CONTROLS. Cfl�c co a 2u�zu�a z` <br /> ARE LOCATED ON FREE-STANDING PEDESTALS, GW�g i T� IIJ zQ wa'dw� <br /> THE CARD-READING CONTROL FUNCTION SHALL E (OMITTED INCLUDES: EXCEPTION, METRIC DIMENSIONS vN �, ° O. °w <br /> � a u <br /> NO MORE THAN 54 INCHES ABOVE AN ACCESSIBLE AND PROTECTION FOR DISPENSER MOUNTED AT GRADE.) (�II�� y� �I�� y r `"rc o <br /> LEVEL AREA WHICH 15 SERVED BY AN ACCESSIBLE JLS� 1J OIvJ II�J /� 'f ° H <br /> PATH OF TRAVEL. l ^ H U <br /> :.i <br /> 00 <br /> ISLAND LAYOUT, TYPICAL OPW S 500-EVR FILL SUMP DETAIL <br /> SCALE: 1/4 - V-O" SCALE: NONE, SOME EXAGGERATION PET - 2 <br /> OF 5HEET5 <br />