0 SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s'qov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Tower Mart #104Facility192 Lathrop Rd., Lathrop Inspection <br />Name: Addresss: <br />AddJan 14 2014 <br />Date: <br />VIOLATIONS <br />## c1 C2 M Cade Section HSC = CA Health and Safety Code, CFR = Code of Federal Regulations <br />C1 = Class i violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) {M7) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Com <br />This is a Routine and Monitoring Certification inspection. The following are violations observed: #204, <br />305,310 <br />204. (Repeat) The designated operator failed to document all the alarms from the attached alarm history <br />on the March 2013 designated operator monthly inspection report and failed to check that they were <br />responded to appropriately. The missing alarms include: Fuel Alarm for Diesel Fill on February 22, <br />2013. During the monthly inspection, the designated operator shall review the alarm history for the <br />previous month, check that each alarm was documented and responded to appropriately, and attach a <br />copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. Submit document of the response to the fuel alarm to EHD by <br />February 14, 2014. <br />305. The 91 -octane STP sump sensor failed to activate an audible and visual alarm when tested to <br />ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />The sensor was replaced and retested during the inspection. A "UST Retrofit Verification with Inspector <br />Already Onsite" form has been completed and provided to the operator and contractor, <br />310. (Repeat) Approximately a liter of liquid was observed in the Diesel fill sump. If water could enter <br />into the secondary containment by precipitation or infiltration, it must be removed and disposed of <br />properly. Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous <br />waste regulations, and manage it accordingly. Ensure that the sump is maintained free of liquid. <br />Technician has removed the liquid and placed it in the hazardous waste container on site. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Title <br />EHD P,42 l9611 9(/1911f / C/ Page 3 UST INSPECTION REPORT <br />