My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 4:34:36 PM
Creation date
11/5/2018 4:47:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\BILLING 1995-2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br />a -- <br />MARK ONLY ® 1 NEW PERMIT ❑ <br />3 RENEWAL PERMIT <br />O 5 CHANGE OF INFORMATION <br />❑ 7 PERMANENTLY CLOSE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ <br />4 AMENDED PERMIT <br />❑ 6 TEMPORARY TANK CLOSURE <br />❑ B TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />SU eAe C4ga <br />E/C -*loq /72 /-RitinD <br />RPG iathrD C0.. <br />I TAMK nFsr.RIPTInN MUM FTP All ITEMS- <br />SPECIFY IF UNKNOWN <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />A OWNER'S TANK I. D. # / <br />(! - S <br />B. MANUFACTURED BY: E2N <br />LOV /-fY <br />C. DATE INSTALLED(MOIDAY/YEAIR) <br />D 6-l5- $' <br />D. TANK CAPACITY IN GALLONS: �O DD <br />❑ 2 WASTE <br />It TAMK P.nuTFNTs IF AA IS MARKED. COMPLETE ITEM C. <br />A 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />B.C. <br />❑ 18 REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br />ED1D PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br />❑ 2 PETROLEUM ❑ 80 EMPTY <br />1 PRODUCT <br />iC MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br />❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A S. #: <br />111 TAKIV PnMQT0I If TInM umV nMC I�KA nui v IM ROYFR A R ANn C. ANO ALLTHATAPPLIES IN BOX D AND E <br />ITT OIDMG IMFnou ATInN PIo,C A IF ARnVF rPnI Nn OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. <br />® 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br />A. TYPE OF <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SINGLE WALL IN A VAULT <br />❑ 99 OTHER <br />B. <br />❑ 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />O 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />8 100% METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />C. INTERIOR <br />❑ I RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />LINING OR <br />❑ 5 GLASS LINING <br />® 6 UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />COATING <br />IS LINING MATERIAL COMPATIBLE <br />WITH 100% METHANOL? <br />YES _4/_ NO— <br />D. EXTERIOR <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />4 FIBERGLASS REINFORCED PLASTIC <br />CORROSION <br />❑ PROTECTION <br />❑ 91 NONE <br />❑95 UNKNOWN <br />❑ 99 OTHER <br />PROTECTION <br />5 CATHODIC <br />SPILL CO MAI NMENTI�JSTALLED(YEAR) <br />OVERRLLPREVENDON EQUIPMENT INSTALLED (YEAR) <br />✓ V NO <br />E. SPILL AND OVERFILL, etc. DROP TUBEYES_J! <br />NO_ STRIKER PLATE YES NO <br />DISPENSER CONTAINMENTYES <br />ITT OIDMG IMFnou ATInN PIo,C A IF ARnVF rPnI Nn OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. <br />SYSTEM TYPE <br />A U <br />1 SUCTION <br />A U <br />2 PRESSURE A U <br />3 GRAVITY A U <br />4 FLEXIBLE PIPING A U 99 OTHER <br />B. <br />CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A@ <br />2 DOUBLE WALL A U <br />3 LINED TRENCH A U <br />95 UNKNOWN A U 99 OTHER <br />C. <br />MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U <br />A U <br />A U <br />2 STAINLESS STEEL A U <br />6 CONCRETE A U <br />10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC)A U 4 FIBERGLASS PIPE <br />7 STEEL W/COATING A UO 8 100% METHANOL COMPATIBLE W/FRP <br />A U 95 UNKNOWN A U 99 OTHER - <br />D. <br />D. <br />LEAK DETECTION <br />® <br />MEGINOGL uxE IFA¢ <br />oErEcrCa ❑� <br />2 uxE rNxlrass 3 LONTIMIWS N WW. 4 FIECIRWIC UNE <br />® uaaronNG ❑ [EAI( DEIELTOR <br />5 AW%tAnC P9MP 99 orHDT <br />sNulCovm ❑ <br />V. TANK LEAK DETECTION <br />❑ 1 VISUAL CHECK ❑ 2 MANUAL <br />RECONCILIATION ORY ❑ 3 MONITORING ®4 GAUGING AUTOMATIC TANK E]5 GROUND MONITORING TESTING <br />F-78 TTEESTINGTANK <br />® 7 CONTINUOUS INTERSTITIAL ❑ 8 SIR ❑ 9 WEEKLY MANUT <br />AL ❑ 10 MONTHLY <br />TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br />MONITORING <br />VI. TANK CLOSURE INFORMATION (PERMANENT CLOSURE IN -PUCE) <br />1. ESTIMATED DATE LAST USED(MO/DAY/YR) 2. ESTIMATED OUANTTTY OF 3. WAS TANK FILLED WITH YES ❑ NO❑ <br />SUBSTAGE REMAINING GALLONS INERT MATERIAL 7 <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />TANK OWNER'S NAME /f • ,. - ,%� Q� DA/TAE <br />(�WrE0 61GN�IREj I - �f, {/( /p A/ /1. /T ntC_y%" IlS l l d <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # 47 0705! TANK # 002- <br />STATE <br />O2STATE I.D.# m l51015 $ lP 5 0 I 5 I 8 (o <br />PERMIT NUMBER I PERMIT APPROVED BY/DATE PERMIT EXPIRATION UATE <br />MUST BE COMPLETED <br />FOR <br />THIS FORK MUSTSHOULDCOULD BE AC//O���MPAnNIIED BYY,,,A PLOT PWFKEFORMA, UNLESS A THIS FORM WITH THE CURRENT <br />OCAL AGENCY IMPLEMENTING THqWNS. THIS Fr <br />RGROUND STORE E TANK REGULATIONS <br />FORM (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.