Laserfiche WebLink
UST SYSTEM DRAWING INFORMATION • • <br /> 1. Three complete sets of plans (include manufacturer's specification sheets for proposed equipment to be installed). <br /> 2. // Plans drawn to scale in non-erasable print. <br /> 3. _✓ Plot plan to show location of tanks and all associated piping. <br /> 4. Striker plates or drop tube-mounted bottom protectors illustrated below all accessible openings. <br /> 5. Tank cross-sectional diagram. <br /> 6. ✓ Detail of tank, associated piping, excavation and cover. <br /> 7. f"" Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Chapter 16, <br /> Article 3, Section 2631 (b) 8 26351 <br /> 8. _✓ Verification of product compatibility with the tank(s), piping, monitoring <br /> / device(s), epoxy or silicone glues, etc. <br /> 9. k Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. <br /> 10. ✓ At the installation site, prior to installation, a tightness test shall be performed on both primary (10) and <br /> secondary (20) containment systems before covering; (Section 2635 (a) (3) 8 (01 <br /> 11. ✓ Tank integrity test required upon completion of installation with tank in operating condition. Test results to be <br /> submitted directly to PHS-EHD from the testing company or owner of facility. [Health 8 Safety Code, Division 20, <br /> Chapter 6.7, Section 25291 (h)] <br /> 12. TANK COMPOSITION ot <br /> TANK # # I # Z # 3 # # <br /> CAPACITY o)0 000 20,000 ZO 000 )2,000(1�7 VZd <br /> MANUFACTURER 9' Xf � )� Mi wE(q MCI" <br /> COMPOSITION .SLrle F lz A-aaep1w 5 wmp <br /> MODEL 65I(I GS GS I(v G5l(n c,- <br /> PRODUCT <br /> PRODUCT 9Tp (.QJ 99 U.S 92 bl,Q Pf'c e(�it2 <br /> FiCp <br /> CORROSION PROTECTION I' OZlc+4R I'nOoel F C' C' <br /> U.L. LISTED I'Ja6 I7y6 174(, 17'4 f7 <br /> COMPATIBILITY WITH 100%, yeti Ye Ye-1) Y&-J yeo <br /> METHANOL <br /> 13. TANK(s) TO BE INSTALLED <br /> A. SteeL-clad with fiberglass reinforced plastic coatings, composites, or equivalent non-metaLLic exterior <br /> coatings or coverings. <br /> i (1) Tested at the installation site using an electric resistance holiday detector. <br /> (2) Vacuum applied to interstitial space. <br /> S. Fiberglass <br /> (1) Installation instructions require an air test and soap bubble test prior to installation. <br /> (2) Vacuum applied to interstitial space. <br /> (3) Hydrostatic annular (primary tank pressure test). <br /> C. Non-clad steel tank [Section 2635 (a) (2) (A)] <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br /> etc.). <br /> (2) Field installed cathodic protection systems designed and certified as adequate by a <br /> corrosion specialist. <br /> (3) impressed current systems to be inspected no less than every 60 days. <br /> 5 <br />