09/27/1995 11:30 1-510-65B-8448 SHIELDS HARPER CO PAGE 01 <br /> ,. Volumetric TTT Methdd • TLS- Oi T -350 UST nit ring Ysteins <br /> Version_ 8473 Digital Sensing Probe Magnetostrictive <br /> Limitations on the Results <br /> The performance estimates above are only valid when: <br /> • The method has not been substantially changed. <br /> • The vendor's instructions for using the method are followed <br /> • The tank is no larger than 15,000 gallons. <br /> • The tank contains a product identified on the method description form. <br /> *The method tests the tank below the liquid level ' <br /> • The tank is at least 95* percent full. Associated testing (at MRI); of the system as an <br /> ATG demonstrated that the method is valid when the tank is 50-959 full . <br /> • The waiting time after adding any substantial amount Of product to the tank <br /> is at least R.95 hours, <br /> • The temperature of the added product does not differ more than <br /> 8.57 degrees Fahrenheit from that already in the tank. <br /> • :The wafting time between the end of "topping off," if any,and the start of <br /> the test data collection is at least NA hours. <br /> The total data collection time for the test is at least 3 hours. <br /> Large vapor pockets are identified and removed (for methods that overfill the tank). <br /> • This method E can ❑cannot be used if the ground-water level is above <br /> the bottom of the tank. See other limitations below.* <br /> • Other limitations specified by the vendor or determined during testing: <br /> * in. n `unction with an ATG_Mtem. if the groundwat r level <br /> is above .the bottom of the tank, a non-tight tank is detected by means o <br /> continuous monitoring of the water level in the bottom of the tank by an 'ATG S stem. <br /> Satety disclaimer: This test procedure only addresses the issue of the method' <br /> ability to detect leaks. It does not test the equipment for safety hazards. <br /> Certification of Results <br /> certify that the volumetric tank tightness testing method was operated according to the <br /> vendor's instructions. I also certify that the evaluation was performed according to the <br /> standard EPA test procedure for volumetric tank tightness testing methods and that the i esutts <br /> presented above are those obtained during the evaluation. <br /> Dr. J.D. Flora Jr. Mr. G. Joe Hennon MIDWEST RESEARCH INSTITUTE <br /> (printed name organ on performing evaluation) <br /> KansasCit , Missouri 64110' <br /> Ksignature o g, <br /> zlp <br /> -Anril 26, 1991 <br /> (8.16) 753-7600 l <br /> ne number) <br /> 1 <br /> Volumetric TTT Method -Results Form <br /> Page 2 of 2 . . <br />