My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2109
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LIBERTY
>
21850
>
2300 - Underground Storage Tank Program
>
PR0528163
>
COMPLIANCE INFO_PRE 2109
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2022 4:40:01 PM
Creation date
11/5/2018 4:51:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2109
RECORD_ID
PR0528163
PE
2351
FACILITY_ID
FA0000267
FACILITY_NAME
88 MARKET & GRILL
STREET_NUMBER
21850
Direction
E
STREET_NAME
LIBERTY
STREET_TYPE
RD
City
CLEMENTS
Zip
95227
APN
02120024
CURRENT_STATUS
02
SITE_LOCATION
21850 E LIBERTY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LIBERTY\21882\PR0528163\COMPLIANCE INFO 2008.PDF
QuestysFileName
COMPLIANCE INFO 2008
QuestysRecordDate
8/4/2017 6:19:14 PM
QuestysRecordID
3554456
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued- <br /> Check <br /> B,, <br /> ontinued-CBox Code <br /> section <br /> ❑ 25SC <br /> 290.1(c)(p Piping compatible with material inten ed to be stored. <br /> 25290.2(c)(1) <br /> ❑ 23 CCR Design and construction of piping approved by independent testing organization(e.g.UL). <br /> 2631(b) <br /> ❑ Piping,including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> 25290.1(k) <br /> 25290.20h6) Vapor cove ,fill riser,and vent line piping are secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> Check <br /> Box Code <br /> Section <br /> ❑ 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(6) Manufacturer Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the to at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is fill d to no more than 95 percent capacity;and activate an audible <br /> ❑ 23 CCR alarm at least five minutes before the�ank overfills <br /> 2635(bX2) <br /> ❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to ov, rfilling. <br /> Manufacturer Model <br /> H. CORROSION PROTECTION: <br /> Check <br /> Box Cade <br /> section <br /> ❑ Fiberl jass reinforced plastic(FRP) <br /> ❑ Piping corrosion protection: P Steel with cathodic protection or impressed current <br /> 23 CCR 11Steel ksolated from contact with backfill <br /> 2636(b) <br /> ❑ FRP o�equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> ❑ 23 CCR ❑ Steel ank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> curre t <br /> ❑ Tie-downs,when used,constructed of non-corrosive material or coated steel. <br /> Revised 061108 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.