My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1444
>
2300 - Underground Storage Tank Program
>
PR0232449
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2022 1:56:38 PM
Creation date
11/5/2018 4:53:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232449
PE
2381
FACILITY_ID
FA0003693
FACILITY_NAME
COLOMBO/TOSCANA
STREET_NUMBER
1444
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16503005
CURRENT_STATUS
02
SITE_LOCATION
1444 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINCOLN\1444\PR0232449\BILLING 1986-1994.PDF
QuestysFileName
BILLING 1986-1994
QuestysRecordDate
8/3/2017 3:20:48 PM
QuestysRecordID
3550249
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI0 WATER RESOURCES CONTROMPARD <br /> FORM `B': UNDERGROUND STORAGE TANK PRO AM <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: LjKrCnl,,j STC, I FARM TANK-YES❑ NO Rl O <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK IDA ?j B. MANUFACTURED BY: <br /> C. YEAR INSTALLED UK D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. � MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ I UNLEADED �2 LEADED ❑ 3 DIESEL <br /> E] 3 CHEMICAL PRODUCT F <br /> ❑ 4 OIL 1 / 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.P'. <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.k <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑�-�T 1�DOUBLE WALLED F-] 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM E&SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> IL&I STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑� 2 ALKYD LINING F-] 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> C.INTERIOR F-] 5 GLASS LINING L&UNLINED ❑ 95 UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 10096 METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENEWRAP ❑2 TARORASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ® 91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A(U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A(Dl STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> 1 VISUAL CHECK OP <br /> V✓l P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 5 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? E]GALLONS <br /> [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY R JURISDICTION N AGENCY k F t ID k TANK ID N <br /> CURRENT LOCAL AGENCY FACILITY I k APPROVED BY N PHONE M WITH AREA CODE <br /> l <br /> PERMIT NUMBER PERMIT APPROVALDATE PERMIT EXPIRATION DATE <br /> CHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: <br /> sk <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIE A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A dWENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />