Laserfiche WebLink
&.O. rap HARDWARE SCHEDULE <br /> # tO Tank: Modern Welding, Gone (7l Envirotank with two (2) 43" <br /> rs , NOTE: LD. containment dams, one (i) dam to have two (2) 4' NPT <br /> 44X Hwy Fsrcr CONTRACTOR SMALL COORDINATE NTH PACIFIC BELL MAXHAVE fittings 16" centers, other dam three (3) 4" NPT fittings <br /> rer 4. rqr PRODUCT TAGS INSCRIBED WITH TANK SIZE (GAL'S), AFILL 10" centers, hold down strops with wire rope dips, one (1) <br /> 04. <br /> ww6 CAPACITY (GAGS), AND FUEL TYPE. gauge stick and tank chart. <br /> 2'_0" ry - # O Piping Sump: American Containment fiberglass piping sump <br /> CHAMFER TVP. 8" THICK REINFORCED CONCRETE SLAB WITH #4 REBAR 42" diameter with 33" diameter riser. Cut or extend to <br /> 12" O.O, BOTH WAYS OBSERVATION PORT IN BACKFILL©O 8 height in field to bury depth. Contractor to order <br /> OUTLINE OF <br /> P-4 extensions if necessary. <br /> / r— <br /> 3" MIN, 6" MAX, (7YP,AT PERIMETER) TANK BELOW NOTE, # O Sump Lid: PHIL-TITh sump shield <br /> _ _ _ _ ALL DUNG OPENINGS ARE _ 33" diameter, match fitting configuration <br /> 4" N.P,T. UNLESS NOTED # O Manhole at fill: For Diesel only, PHIL-PTE $C 3600-SCA, <br /> / OTHERWISE. w/ 5 GAL. spill containment box, Openings shall match <br /> COLD KEY CONSTRUCTION JOINT AT SLAB tank bung configuration. <br /> I I I MIDPOINT FOR TANKS OVER 3000 GALLONS # 5O Fill Cop and Adaptor Emco Wheaton A20-005 cap and Emco <br /> Wheaton A30-014 aluminum hard coaled 4" diameter adapter. <br /> rI I I �- �'�- -- PRODUCTD SEEBULKHER 27 FILL SPILL CONTAINMENT BOX # Fill Drop Tube: Emco Wheaton A20-004, aluminum submerged <br /> LIQ MULTI PORT MANHOLE WITH O drop tube, field cut. Contractor Shot( order to fit proper <br /> 4"0 SECONDARY FILLER CAP AND ADAPTER 6 tank diameter. <br /> PIPE 26 LIQUID TIGHT FILL BOX I.D. TAG # O Angle Check Valve: Universal 405 double poppet volve <br /> PRIMARY SUPPLY <br /> PHIL-TITS SUMP SHIELDO 'or <br /> FILL ASSEMBLY, SEE ® I TON/ 10" LINE 25 Foot Valve with extractor, Emco Wheaton A439-005, <br /> - PRIMARY RETURN # ® Extroctor Bali Float: Universal 37- <br /> 1 VENT LINE WITH EXTRACTOR VALVE ASSEMBLY I / ` \ I LINE O 206076 with Universal <br /> RISER AT SUCTION TUBE. / / � 25 V421-20-20 extractor housing. <br /> OUTLINE OF SUMP BELOW I / // v 36"0 X 12" DEEP <br /> - OTonk, <br /> level Probe/Overfill Alarm M 90 percent: Veeder-RootWATER-TIGHT 350-I I-1 MANWAY, SEE _ - - - -j_1_ OUTLINE OF CROWN AT CONCRETE <br /> TANK LEVEL RISER # 10 unctionebooctor Sensor. TL5350 sensors with cables to <br /> j <br /> AND PROBE. I I <br /> OF <br /> \ ( ) I 1, R ` v ;\.I I / / ` BUNGS TANK k ' .J""BOX (TYP,) -__- - - - 4" PIPE CAP 12 RisersGasoline tsubject t oil efor ,D� wrapped with corrosion <br /> T _ _ - _ - _ 11 Riser Pipe: Schedule 40 block r <br /> resistant tom <br /> for <br /> or <br /> / 4'S AT 45' ANGLE AROUND MANHOLES TYP. / EXPLOSION PROOF <br /> ra. Galvanized schedule 40 <br /> esel. <br /> 15 \ / (TTP, / / I I RI 0 PIPING SUMP WITH 37 m # 13 Flex connector, 1-1/2" diameter x 12" long, Titeflex <br /> RISER, SEE 4" BLACK IRON RISER <br /> 110165-24-0120 for 2" diameter x 12" long Flex connectors, <br /> Titeflex 110165-32-0120 male x mole swivel. Titefbx only, <br /> SEAL-OFF_ no equals. <br /> -'sr-- LOOP 3/4"C, TO "J" BOX AT 2" 0 F,R.P <br /> ANNULAR POe MON .ITOR, I /` I I ANNULAR SPACE RISER. VENT LINE # 14 Manhole Cover of Annular Monitor: Universal 98-1810, 18" <br /> ' I8" 0 MANHOLE BOX FRAME AND O <br /> COVER, SEE 14 I -H - LOOP 3/4"C. TO SUCTION/ diameter. <br /> # 1S <br /> III I I. VENT/TLM SUMPAnnular Cop: Veeder Root sensor riser ca. 22 PIPE PENETRATION ® SUMP. BULKHEAD O Pond adoDtor kit. <br /> I— I NO CHAMFER IF O (TYP I EAl)ERT. SEE ZI I6 Riser Cap: 4" diameter threaded cop with extractor wrench <br /> MIN. ALL-AROUND, FOR SINGLE TANK. 1'-0" -- I ADJOINING WING OTHER p-q top fitting, <br /> WIDE WHERE ADJOINS ADDITIONAL TANKS - - I I - / TANK SLABS SUMP SENSOR PROBE, SEE 10 <br /> J 13 FLEX CONNECTOR <br /> L _ — - - - - - - - - - - - - - - - - - - - - �.. _ _ _ _ _ _ a <br /> V <br /> -I - I- - - 4'- - 4" 0 BLACK IRON RISERSFIBERGLASS SUMP TO CONTAINMENT DAM handle skirt reinforced cover, screws, gasket and pull <br /> FOR DIESEL, SEE PER SUMP MANUFACTURER'S SPECS. # 18 Overfill Prevention Valve: Emco Wheaton Guardian A1100-001. <br /> CONTAINMENT.DAM PROVIDED <br /> BY TANK MANUFACTURER, # 14 Product ID/Capacity Tag; Provide stamped plate with product <br /> 2'-0" WIDE MIN. SPACE and ca acit Universal 56D for diesel Universal 56U for <br /> TO ADJACENT TANKS P y <br /> unleaded. <br /> 95% SHUT-OFF PIPs, locking <br /> SET HEIGHT FOR # 20 Observobon Port Kit: Includes slotted PVC g <br /> VERIFY DIMENSION WITH - - - O cop and manhole' <br /> TANK FURNISHED 4" X 4" 2" EXTRACTOR/BALL VALVE # 21 Bulkheads fittings and connectors for fiberglass piping: <br /> AT VENT LINE. SEE© Total Containment flat bulkhead fitting FB3650 <br /> CONTRACTOR TO Total Containment T pipe insert CS3920 <br /> SUPPLY EXTRACTOR WRENCH. Total Containment 3" pipe insert CS3930 <br /> 22 Bulkhead fitting for conduit'. <br /> Total Containment 3/4" flat bulkhead fitting FB1000 <br /> OVER FILL PREVENTION VALVE, # 21 Test Reducer: Total Containment TR4200 for 4" to 2" <br /> SEE (1-8) reduction. TR4300for 4" to 3" reduction <br /> NOTE' 18 24 NOT USED <br /> SEE SITE PLAN FOR <br /> FUEL PIPING SIZE # 25 PRIMARY PIPING: PRIMARY PIPING SIZE VARIES, SEE <br /> O SHEETS P-1 AND P-2 TO CONFIRM SIZES <br /> 1 <br /> 1/2" ENVIROFLEX #PP0500 TANK SLAB PLAN SCALE NONE 3 FILL / VENT SUMP DETAIL SCALE I"-1'-0" 3/4" ENVTROFLEX #PP0750 <br /> 1" ENVIROFLEX # <br /> 1 1/2" ENVIROFLEX # <br /> 2" EN14ROFLEX # -IN WET HOLE OR UNSTABLE SOIL CONDITIONS- - # 26 SECONDARY PIPING', PRIMARY PIPING SIZE VARIES, SEE <br /> INSTALL FILTER FABRIC LINING AT TANK - SHEETS P-1 AND P-2 TO CONFIRM SIZES <br /> HOLE ON ALL SIDES AND BOTTOM. LAP 4' ENVIROFLEX #SP4000 <br /> REINFORCED CONCRETE SLAB AT TOP OF EXCAVATION A MIN OF - # 27 ENVIROFLEX PIPING: BULKHEAD FITTING <br /> 2'-0", PLACE PRIOR TO INSTALLATION FOR ROUND SUMP USE <br /> 12" MIN. CROWN WIDTH (TYP.) \ OF DEADMAN. TOTAL CONTAINMENT #C 83650 AT PRODUCT LINE <br /> ANNULAR CAP, SEE 75 _3 \ TOTAL CONTAINMENT #CB3950 AT VENT LINE <br /> 7 OR FOR FLAT FACED SUMP USE <br /> -� P43 MANHOLE AND COVER, SEE 17 i TOTAL CONTAINMENT #C83650 AT PRODUCT LINE <br /> y 3/4" C. TO BONES FOR TOTAL CONTAINMENT y MONITORING PROBES 1" TO 3" HIGH CROWN (TYP) O #CB3950 Ar VENT LINE <br /> CONCRETE <br /> E _ CONFIRM HEIGHT NNTH <br /> ANWAY$ DUPLEX T07AL CONTAINMENT, SZE VARIES <br /> # 28 TEST DONUT <br /> SUC <br /> N RISER <br /> o ro <br /> JIF W -- PACIFIC BELL ENGINEEADASUCPTER AND RETURN) EE nEXTRACTOR4WRENCHVTOP RAP29 7fR TAL CONTAINMENT <br /> -0 No - - - - - - - - - - - - - - - - - - - - - - - - "�� GASO'I1NE 12R BBACK IRON FOR DIESEL SUMP LID, SEE ,# 30 TERMI'� TNATION PLUG <br /> ( TOTAL CONTAINMENT #TP3000 <br /> I"C. WITH SEAL- NATION ASSEMBLY <br /> FROM "J" 80% Tx 3" TOTAL CONTAINMENT #TA4000 <br /> MONITOR PANEL. 2' FIBERGLAS$ z TANK LEVEL RISER AND PROBE. SEE 931 FULL PORT BALL VALVE: SIZE VARIES <br /> VENT LINE I r CONTRACTOR TO PROVIDE RISER OSIZED PER VEEDER ROOT,'S 1 i/2" UNIVERSAL #213 FP-15 <br /> 20 MIL, POLYETHYLENE VAPOR BARRIER I z - REQUIREMENTS. SEE SHEET P-5, 2" UNIVERSAL #213 FP-20 <br /> ® V-0" FROM GRADE. - = a ' - - - - - - NOTE 7 <br /> N 2" 0 PVC PIPE _ __� , Io & # NOTE: Items marked with one asterisk are furnished by owner,installed by contractor, unless noted otherwise on drawing. <br /> FOR ANNULAR PNOTEro ENVIROFLEX PIPING SHALL BE USED AS PACIFIC-BELL STANDARD <br /> Ia ON FUEL OIL SUPPLY AND RETURN LINES <br /> FULL PORT BALL VALVE, SIZE VARIES <br /> - I BULKHEAD WITH PIPE (TYP, AT SUCTION AND RETURN) SEE 31 FIBERGLASS CONTAINMENT SUPPLY & RETURN SHALL BE USED ONLY <br /> - - - - - - - - - - '� ^• - - - - - - - - - 'CAB-LE <br /> - - - - - - - - - - .� - INSERT, SEE 22 PRIMARY SUPPLY LINE, SEE 25 WHEN REQUIRED BY SITE CONDITIONS OR LOCAL AGENCIES. <br /> ' M SUMP SENSOR PROBE. I - - - - 1 O <br /> SEE 10 I 11 STAINLESS STEEL HOLD DOWN CABLES BY GENERAL ` i I LOOP 3/4"C. TO "J" BOX EXPLOSION PROOF "J" BOX (TYP,) ROBiiiT N. LYi 6 ASflOC1ATBSq INC. <br /> III I CONTRACTOR, FELT SEPARATOR AND CABLE GUIDES \ PROBE RISER MOMENT <br /> RA S EIMYNfNC. <br /> QN 2' 0 N.P.T. BUNG---/ II /J FURNISHED `WITH TANK, INSTALLED BY GENERAL I I AT ANNULAR SPACE 4"0 SECONDARY CONTAINMENT i.or ro.lm>wELL etw. rsvaw,.,u, sessa oan ,rm-"sso <br /> ® ANNULUS I III CONTRACTOR, SEE 1 �-" —/ I I rI \ <br /> —� PRIMARY RETURN LINE, SEE 25 <br /> III P-4 I I12 .u-N w..nnr�x nP[HTpGT <br /> I 11 I s xvE&n Y.awv ENfFEn <br /> II 2" 0. BLACK IRON <br /> III SUCTION TUBE / 27 <br /> II I I 16 <br /> o III 3-7/8" O,D. ALUMINUM SUBMERGED FILL DROP <br /> EXTRACTOR CAP, SEE <br /> (TYPBULKHEAD FITTING, SEE <br /> ) ® SIDES & O <br /> n TUBE, SEEI BOTTOM DUPLEX TEST DONUT, $EE 28 <br /> I e III O I It 1'-0" 4" NIPPLE PIPE PENETRATION ® SUMP. BULKHEAD <br /> if III STEEL WALL UNDERGROUND PRIMARY STORAGE TANK MIN, ANGLE CHECK VALVE WITH PIPE INSERT AND TEST REDUCER. <br /> II WITH STEEL REINFORCED PLASTIC I I 7O SEE <br /> SECONDARY <br /> 21 -- <br /> III COMPOSITE SECONDARYARY TANK. CONTRACTOR WITH STRAINER, SEE <br /> II TO VERIFY EXACT SIZE OF TANK PRIOR cPPONAL FOOT VALVE MAY I I P-4 <br /> III TO PROVIDING A BID OVOTE, SEE 6E USED IN LEV OF ANGLE <br /> CHECK VALVE IN-TANK GAUGE PROBE v N0. REVISIONS / AUTHORIZATIONS DATE BY <br /> 111 O � I I W/907> OVERFILL ALARM 42" 0 X 33" 0 FIBERGLASS <br /> CONTRACTOR i0 CALIBRATION, INSTALL - - - - _ - - - - - _ _ _ REDUCING PIPING SUMP W/ UD <br /> III FIELD CUT ® 20" SQUARE X 1/4" THICK STEEL PROTECTOR (TYP. OF 2) I PER MFR'S REOMNT'S.. - FURNISHED W/ TANK, SEE TANK SECTION <br /> I BOTTOM BY TANK MANUFACTURER I SEED <br /> it <br /> 4"x4"x2" TEE NTH REDUCER (TYP, OF 2) <br /> " O2 <br /> SLOPE TANK 1/8" PER FOOT DOWN TOWARDS MONITORING FOR RETURN LINE SLAB PLAN AND DETAILS <br /> 'II2" MIN'�y�,7� " MAXIMUM PROBE AT ANNULAR SPACE. I _ _ <br /> Ou I gL - .41- .- - - _- - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - - � -I- - J 4" NIPPLE SUMP SENSOR PROBE, SEE 10 DRAWINGS PREPARED FOR <br /> N - I 4 TO 6 - PLUG OPENING FEMALE COUPLING (TYP.) <br /> rn -"- '-"-- LENGTH TO MATCH TANK _ <br /> PACIFIC BELL <br /> FACILITY ADDRESS SACRAMENTO, CALIFORNIA <br /> PRECAST CONCRETE DEADMAN, TWO <br /> PER TANK, FOR SIZE SEE RI r(( I PEA GRAVEL BACKFILL 907 LINCOLN ROAD <br /> 1 _ (TYPICAL) - <br /> U LIQUID DETECTOR PROBE AT 726-8" P-q <br /> li <br /> ANNULAR SPACE TLS-350 CONFIRM WITH TANK MANUFACTURER STOCKTON CALIFORNIA <br /> SEE 10 NOTIES I. . . I ' <br /> 1. TANKS ARE SHIPPED 'NTH VACUUM PRESSURE ON ANNULUS, VERIFY THAT VACUUM IS INTACT PRIOR TO INSTALLATION JAN 3 0 1997 - - - DATE: 1/22/97 DRAWN BY: KGM <br /> o - 2. PERFORM A STATE CERTIFIED PRECISION TEST AFTER PLACING FINISH YARD MATERIALS, <br /> Z SEEPROJECT ENGINEER CHECKED BY: J, McGRATH,TESTING REQUIREMENTS ON SHEET P-6. - <br /> Z <br /> EST/RO NO, SHEET 3 OF 7 SHEETS <br /> SECTION <br /> .- APPROVED DRAWING N0. <br /> `E Z TANK SSCALE: NONE ., - SCALE: 1"=1'-0" MANAGER UE046-0001 ] P-3 <br /> � . 4 SUCTION / VENT / TANK LEVEL SUMP <br /> 'tFEF' - - <br />