BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINDBERGH
>
6250
>
2300 - Underground Storage Tank Program
>
PR0231640
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2022 10:04:02 AM
Creation date
11/5/2018 5:08:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231640
PE
2381
FACILITY_ID
FA0003832
FACILITY_NAME
SIERRA JET LLC
STREET_NUMBER
6250
Direction
S
STREET_NAME
LINDBERGH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726026
CURRENT_STATUS
02
SITE_LOCATION
6250 S LINDBERGH ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINDBERGH\6250\PR0231640\BILLING 1986-2000.PDF
QuestysFileName
BILLING 1986-2000
QuestysRecordDate
8/3/2017 3:13:21 PM
QuestysRecordID
3550183
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STATE OF CALIFORNIA • .�'°°" ` <br /> C� S�[-_t _ STATE WATER RESOURCES CONTROL BOARD =P c <br /> \` /( UNDERGROUND STORAGE TANK PERMIT APPLICATION •FORM B : ` o <br /> Y.�.'6. o' <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. �� <br /> owH,. <br /> MARK ONLY LD-:;Il <br /> 1 NEW PERMIT ❑ 3 RENEWAL PERMIT c•" <br /> ONE ITEM 2 INTERIM PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED <br /> ❑ 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE <br /> ❑ 8 TANK REMOVED , <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: G - <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A, OWNER'S TANK I.D.a <br /> B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAV/YEAR) <br /> D. TANK CAPACITY IN GALLONS; oJAIll I <br /> ILTANKCONTENTS IFA-i IS MARKED,COMPLETE ITEM C. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. 0 flEGULAR <br /> 2 PETROLEUM C. ❑ LEADED 3 DIESEL 6 AVIATION GAS <br /> ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM 4 GASAHOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE UNLEADED ❑ 5 JET FUEL ❑ 7 METHANOL <br /> ❑ 2 LEADED ❑ 98 p7HER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.x: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C.AND ALL THAT APPLIES IN BOX D AND It <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> SYSTEM 2 SINGLE WALL ❑ ❑ 95 UNKNOWN <br /> 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS <br /> ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ g POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br /> (PrimaryTank) ❑ g BRONZE ❑ e 100% METHANOL COMPATIBLE W/FRP <br /> ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING <br /> C.INTERIOR ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED �/ <br /> DES 95 UNKNOWN ❑ W OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL 7 _ <br /> YES_ NO --- <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING <br /> ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 96 UNKNOWN <br /> ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) <br /> OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION <br /> CIRCLE AIFABOVEGROUNDORUIFUNDERGROUND,BOTHIFAPPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION p U 2 RESSURE <br /> A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL A U-2 DOUBLE WALL <br /> A U 3 LINED TRENCH p U 96 UNKNOWN. p U 99 OTHER <br /> T <br /> C. MATERIAL AND AIqq (lBARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE( U 4 FIBERGLASS PIPE <br /> CORROSION A 5 ALUMINUM p U 8 CONCRETE <br /> PROTECTION A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESSA U 99 OTHER <br /> TESTING ❑ UONROgING 99 OTHE <br /> V.TANK LEAK DETECTION <br /> ❑ 1VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING E] 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> 8 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE <br /> ❑ 95 UNKNOWN ❑ gg OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED TE AST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF <br /> SUBSTANCE REMAINING3.WAS TANK FILLED WITH ❑ ❑ <br /> GALLONS INERT MATERIAL. YES NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNO <br /> APPLICANTS NAME WLEDGE, IS TRUE AND CORRECT <br /> (PRINTED 8 SIGNATURE( DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE I.DA 3LITY# (Z a3 i <br /> COUNTY# JURISDICTION# FACI —T TAN <br /> PERMIT NUMBER PERMIT APPROVED BV/DATE ILUI IL ILEI IL J � V <br /> PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORMA,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (12-91) /..//, <br /> IqFOR091M18116 <br />
The URL can be used to link to this page
Your browser does not support the video tag.