Laserfiche WebLink
o- • Appendix VI • <br /> (Copies or Monitoring System Certification form and UST Monitoring Not Plan available athttp;//wwwswrb.ca.eoy,) <br /> MONITORING SYSTEM CERTIFICATION <br /> ror Use By All Jurisdictlons Within the Stale of California <br /> AIM rority Cited. Chapter&7, fleahh and Safety Cdde;Chapter 16,Division 3, Title 23,California Code of Regulations <br /> This form'must ba used to decumc11L testing and servicing of monitoring equipment.l . ml must he tc cication or the repornk t muststenn be pre pored o r Quch <br /> The <br /> monitoring aystom control by the technician who performs the work. A copyprovided <br /> owner/operatnr must submit a cagy of this form to the local agency regulating US-T systems within 30 days of Inst date. <br /> A. General Information <br /> Facility Name: San Joaquin RTD Bldg,No.: <br /> Site Address: 1533 I;. Lindsay St. City: Stockton lip 95205 <br /> Facility Contact Person: Doug Smith Contact Phone No.: 209.945.5566 <br /> Make/Model of Monitoring System: INCON 2001 Date of Testing/Servicing: June 30,2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriote holes toindieate s ucifiee ui ment Ing reted/serviced: <br /> Tonic ID; #1 Tank ID:03 <br /> In-Tank Gauging Probe. Model: ,._ 17 In-Tank Gauging Probe. Model:_ <br /> (x)Annular Space or Vault Sensor. Model:TSP-HTS Gd Annular Space or Vault Sensor. Model:TSP-HfS <br /> (t)Piping Sump/Trench Scnsor(s). Model:TSP-ULS O Piping Sump/'trench Sensar(s). Model:TSP-ULS <br /> El pill Sump Scnsor(s). Model: _ ❑ Fill Sump Sensor(s). Model: ,...— <br /> ( )Mechanical Line Look Detector. Model: ❑ Mechanical Linc l,eak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: __ ❑ Blccuenic Line Look Detector. Model <br /> 0 Tank Overfill/High-Lcvcl Sensor. Mode(: O Tank Overfill/I ligh-Lovel Sensor. Model: <br /> n Others cmc ui mcnt a and model in Section E on Pa a 2). d� Other s cele c ui mcnt typo and model in Seclion r an Pa&c 2). <br /> Tonic ID: #2 'Dank ID:#4 <br /> ( )In=Tank Gauging Probe, Model:_ 0 In-Tank Gauging Probe. Model' <br /> As Annulnr Space or Vault Sensor. Model:TSP-Ii IS 0 Annular Space or Vault Sensor, Model:TSP-HTS <br /> m Piping Sump/'hrench SL`naor(a), Model:TSP-ULS 0 Piping Sump/Trench Scnsor(s). Model TSP-ULS <br /> 0 Fill Sump Somor(s). Model ❑ Fill Sump Sensor(s). Model:_ <br /> M I Mechanical Linc Look Detector, Model'FE PETRO IM Mechanical Line Look Detector. Model: Flt PETRO <br /> C] ricelronic Line I,cak Detector. Model: _ 0 P.lactronic Linc Leak Detector. Model; <br /> L] Took Overfill;FI1gh4.evcl Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: _ <br /> ❑ Other s ecif <br /> equipment c and model in Section E on P e 2 . Q Other s eci c ui ment c and model in Section E on Page 2 . <br /> DIapenser ID:#I .Dispenser ID;#2 <br /> O Dispenser Containment Sensor(s). Model; TSP-ULS IZI Dispenser Containment Sensor(s). Model:'rSP-ULS <br /> Shear Valve(s). 0 Shear Valve(s). <br /> _ Dispenser Contalamont ploat(s)and Chain(s). ❑ Dispenser Containment Float(s) and Chains . <br /> Dispenser ID: 43 Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: TSP-ULS CI Dispenser Containmcnl Sensor(s), Model <br /> SheorVnlve(sL 0 Shear Valve(s). <br /> ❑ Di s cnscr COnminment Float s and Chains . 0 Uispvnsur Containment Floats)and Chain(s). <br /> Dispenser 11): Dispenser -._.- <br /> 11 Dispenser Containment Sensor(s). Model: 0 Dispenser Containment Sensor(s). Model:.___ <br /> Shcnr Vnlvc(sl. ❑ Shear Valve(s). <br /> ❑Dis cnscr CpLnimnent Flual s and Chains ❑ Dispenser Containment Floats and ChLlin s . <br /> •Ir the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility <br /> C. Certification - 1 certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br /> gui(lolines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot PIM showing the Inynut of monitoring equipment. For any equipment capable of generating such reports.I have also <br /> attached a copy of the report;(Check all thnr apply): ( )System set-up ( )Alarm history report <br /> 'I'cehnlaian Name(print); Eric Molgaard Signature: Eti.e ,MoigaaTd <br /> Certification No.: ICC California UST ServiceTech#9250200d)T license Nn.: 309105 <br /> 'resting Company Name;STOCKTON SERVICE STATION EQUIPMENT CO.INC. Phone No 209464.5333 <br /> 'testing Company Address; 905 N.Union Street,Stockton,CA 95205-4152 Dalc of Tcsting/Servicing: June 30.2010 <br /> Monitoring system certificallon rage 1 of 4 12107 <br />