Laserfiche WebLink
G SAN JOAQUIN COUNTY C <br /> �1``..J/'. 16Jiry " <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> b; t <br /> 600 East Main Street, Stockton, CA 95202-3029 <br /> ' Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> �l FOF� <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> San Joaquin Rapid Transit Wednesday, June 30, 2010 <br /> Facility Address: Service Request X: <br /> 1533 E. Lindsay Street, Stockton SR0060408 <br /> Onsite Service Technician's Name: ICC Service Technicianlinstaller Exp.Date: Manufacturer Training: <br /> Eric Molgard 5250200 (11/18/2010) Franklin #4654733760 <br /> SERVICE SERVICE <br /> Leak detector <br /> 19 mechanical Model:Fe Petro STP-MLD(blue) Spill bucket ❑minimum 5 gallon <br /> © 11electronic Serial#:08060807 El ❑ 1 hour hydrostatic ❑Incon TS-STS <br /> ❑ line test programmed ❑Caldwell System ❑Other <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> El ❑mechanical Model: El ❑�hour hydrostatic ❑Incon TS-STS <br /> ❑electronic Serial#: El Caldwell System 11 Other <br /> 11 line test programmed <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑ ❑mechanical Model: El ❑�hour hydrostatic El Incon TS-STS <br /> ❑electronic Serial#: <br /> ❑line test programmed ❑Caldwell System ❑Other <br /> sensor Primary piping testing at: <br /> 11 positive shutdown Model: <br /> ❑ ❑fail safe Serial M ❑ —psi <br /> ❑NA minutes <br /> sensor Secondary containment testing for: <br /> ❑ ❑positive shutdown Model: UDC(s) Piping <br /> ❑fail safe Serial#: Sump(s) UST(s) <br /> ❑NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑positive shutdown Model: <br /> El <br /> ❑fail safe Serial#: Note Please be a ware teal 20 oontanmem mmponents ate reQuretl to"testetl upon <br /> ❑NA imulbtxX s months mer,and ewn w monms meremer_ <br /> ❑ —Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) ❑ Other: see below <br /> 87 grade LD was replaced w/ above FE model on emergency on 6/30/2010. LD passed 3 gph leak <br /> test at 10psi using VMI tester. Technician's VMI cert is #2107 exp. 3/4/2011. The permit application <br /> is to be submitted within 1 business date after replacement. This inspection report has been <br /> generated retroactively on 7/8/2010. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector 4�PE Received By: q I x�$� '0 J 1 Title: <br /> EHD 23-04 UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 06/01/10 - <br />