My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINDSAY
>
1533
>
2300 - Underground Storage Tank Program
>
PR0231158
>
COMPLIANCE INFO 2010-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 11:57:53 AM
Creation date
11/5/2018 5:15:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2013
RECORD_ID
PR0231158
PE
2361
FACILITY_ID
FA0003749
FACILITY_NAME
SJ REGIONAL TRANSIT
STREET_NUMBER
1533
Direction
E
STREET_NAME
LINDSAY
STREET_TYPE
ST
City
STOCKTON
Zip
952054498
APN
15302004
CURRENT_STATUS
02
SITE_LOCATION
1533 E LINDSAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LINDSAY\1533\PR0231158\COMPLIANCE INFO 2010-2013.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209) 468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility SJ Regional Transit Facility 1533 E. Lindsay, Stockton InspeCtion Jun 22, 2012 <br /> Name: g Address: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> Cl =Class i violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) " <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M7) <br /> Other.Violations <br /> 999 Other: See attached 'Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY <br /> CLASS I,CLASS II, MINOR-Notice to Com I <br /> This is a report of the Routine and underground storage tank monitoring system certification inspection <br /> conducted at the referenced facility by San Joaquin County Environmental Health Department (EHD). <br /> The following is a Minor-Notice to Comply violation: #104, 109, 204 <br /> 104. Financial responsibility documents were last completed on June 27, 2011, and the current financial <br /> responsibility document have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually by the time of the Routine inspection. Complete and submit a <br /> copy of the financial responsibility by July 22, 2012. <br /> 109. Annual monitoring system certification including annual line testing, leak detector testing, and spill <br /> container testing were performed on June 27, 2011, and the test report was received by the EHD on <br /> August 16, 2011. A copy of the test report must be submitted within 30 days of the tests. Immediately <br /> begin submitting a copy of the test report to the EHD within 30 days of the tests. <br /> 204. The designated operator failed to document all the alarms and attached alarm history on the <br /> February 29, 2012 and June 29, 2011 designated operator monthly inspection reports. The missing <br /> alarms include: February 1, 2012 and February 16, 2012, and at least June 27, 2011. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history <br /> with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. Observed Doug (designated operator) documented on site the alarms on the February <br /> 2012 designated operator inspection report, and attached a copy of"equivalent' alarm history. Violation <br /> for February 2012 designated operator inspection report was corrected on site. (Doug was unable to <br /> correct the June 29, 2011 report, but it should be noted that the 2011 monitoring system certification <br /> inspection was conducted on June 27, 2011) <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Ins ct Received By: Title'. <br /> EH 23-02 v 01 9/12 a 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.