My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:07:04 PM
Creation date
11/5/2018 5:52:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LODI\2500\PR0231356\BILLING 1985-1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />)uF f,1151o7K <br />UNIFIED PROGRAM (UP) FORM <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />VI. PIPING CONSTRUCTION (Check all that apply) Page of <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SYSTEM TYPE ®1. PRESSURE 0 2. SUCTION 03. GRAVITY <br />458 <br />❑ 1. PRESSURE 0 2. SUCTION ❑ 3. GRAVITY 459 <br />CONSTRUCTION ❑ 1. SINGLE WALL O 3. LINED TRENCH 099. OTHER <br />460 <br />❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />MANUFACTURER ® 2. DOUBLE WALL ❑ 95. UNKNOWN <br />❑ 2. DOUBLE WALL ❑ 99. OTHER <br />MANUFACTURER ENVIRON <br />461 <br />MANUFACTURER 489 <br />MATERIALS AND EI1 BARE STEEL O 6. FRP COMPATIBLE W/100% <br />01 BARE STEEL ❑ 6. FRP COMPATIBLE W/100% METHANOL <br />CORROSION METHANOL <br />PROTECTION 0 2, STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />[195. UNKNOWN <br />[12. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ® 8. FLEXIBLE (HDPE) <br />❑3. PLASTIC COMPATIBLE ❑ 8. FLEXIBLE (HDPE) El 95. UNKNOWN <br />W/CONTENTS <br />[14. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br />0 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br />❑ 5. STEEL W/COATING ❑ 99. OTHER 484 <br />1 O 5. STEEL W/COATING ❑ 99. OTHER 465 <br />VII. PIPING LEAK DETECTION (Check all that apply) (A des ai tion of me monitchng program shall be submitted to the localagency.) <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466 <br />SINGLE WALL PIPING 467 <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />❑ I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM <br />SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM <br />DISCONNECTION + AUDIBLE AND VISUAL ALARMS. <br />DISCONNECTION + AUDIBLE AND VISUAL ALARMS. <br />[12. MONTHLY 0.2 GPH TEST <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1GPH) <br />[13. ANNUAL INTEGRITY TEST (0.1 GPH) [34. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ S. DAILY VISUAL MONITORING OF PUMPING SYSTEM +TRIENNIAL PIPING <br />0 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />INTEGRITY TEST (0.1 GPH) <br />❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />❑ 7. SELF MONITORING <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW <br />GRAVITY FLOW (Check all mat apply): <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />08. DAILY VISUAL MONITORING 09. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) <br />ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />® b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND <br />❑ b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />SYSTEM DISCONNECTION <br />DISCONNECTION <br />[3c. NO AUTO PUMP SHUT OFF <br />Oc NO AUTO PUMP SHUT OFF <br />X11. AUTOMATIC LEAK DETECTOR (3.0 GPH TEST) WITHFLOW SHUT OFF <br />[111. AUTOMATIC LEAK DETECTOR <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />(112. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVRY SYSTEM <br />SUCTIOWGRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOl1T AUTO PUMP SHUT OFF <br />[114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF' <br />AUDIBLE AND VISUAL ALARMS <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LEAK DETECTOR (3.0 GPH) WITHOUT FLOW SHUT OFF <br />[115. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) O 17. DAILY VISUAL CHECK <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 17. DAILY VISUAL CHECK <br />VIII. DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT <br />❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE [14. DAILY VISUAL CHECK <br />DATE INSTALLED 468 <br />❑ 2. CONTINUOUS DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER / MONITORING <br />® 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6. NONE 469 <br />1997 <br />DISPENSER + AUDIBLE AND VISUAL ALARMS <br />IX. OWNER/OPERATOR SIGNATURE <br />I certify that the information rovl 0ereIn Is Inm and eccurete to the best of my knowledge. <br />SIGNATURE OF W P TOR • <br />4rk� <br />DATE 470 <br />NAME OF Opnn <br />TITLE OF OWNER/OPERATOR 472 <br />Cynthia H. Madrid <br />General Manager, Retail Services <br />UP FORM (1/2000 Version) <br />SBC UST-B.doc <br />Formerly SWRCB Form B <br />