My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:07:04 PM
Creation date
11/5/2018 5:52:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LODI\2500\PR0231356\BILLING 1985-1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROGRAM CONSOLIDATED <br />UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br />UNDERGROUND PIPING <br />SYSTEM TYPE ® L PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br />CONSTRUCTION ❑ I. SINGLE WALL ❑ 3. LINED TRENCH ❑ 99. OTHER <br />MANUFACTURER ® 2. DOUBLE WALL ❑ 95. UNKNOWN <br />MANUFACTURER ENVIRON <br />❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE w/l00% METHANOL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL I ❑ Unknown <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 99. Other <br />❑ 4. FIBERGLASS ® 8. FLEXIBLE (HDPE) <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 <br />VII. PIPING LEAK DETECTION !Cluck al <br />TANK <br />f Check all flute Page of <br />ABOVEGROUND PIPING <br />4M ❑ 1. PRESSURE [12. SUCTION ❑ 3. GRAVITY 459 <br />469 [11. SINGLE WALL ❑ 95. UNKNOWN 462 <br />[12. DOUBLE WALL [199. OTHER <br />461 MANUFACTURER <br />❑ 1. BARE STEEL <br />❑ 2. STAINLESS STEEL <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS <br />❑ 4. FIBERGLASS <br />❑ 5. STEEL W/COATING <br />SINGLE WALL PIPING 466 <br />PRESSURIZED PIPING (Checkal] tlutapply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST W11' AUTO PUMP SHUT <br />OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION+ <br />AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (O.1GPH) <br />CONVENTIONAL SUCTION SYSTEMS <br />❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+ TRIENNIAL PIPING <br />INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check a that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WIT} AUDIBLE AND VISUAL <br />ALARMS AND (Cbeckone) <br />❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />® b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEMFAILURE AND SYSTEM <br />DISCONNECTION <br />❑c. NO AUTO PUMP SHUT OFF <br />[ILL AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WIT FLOW SHUT <br />OFF OR RESTRICTION <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR+ AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check a110W apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />SHUT OFF OR RESTRICTION <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />463 <br />[16. FRP COMPATIBLE W/lO METHANOL <br />[17. GALVANIZED STEEL <br />❑ S. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 9. CATHODIC PROTECTION <br />❑ 95. UNKNOWN 465 <br />SINGLE WALL PIPING <br />PRESSURIZED PIPING (Check ell that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTI <br />AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS (Cheek all that apply) <br />❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />❑ 7. SELF MONITORING <br />GRAVITY FLOW (Cheekall dutapply): <br />❑ 8. DAILY VISUAL MONITORING <br />❑ 9. 13MNNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all out apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) <br />❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEMFAILURE AND SYSTEM <br />DISCONNECTION <br />❑c NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check ell thatepply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />VID. DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT ® 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br />DATE INSTALLED w ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+ AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER /MONITORING <br />1997 ❑ 3. CONTINUOUS DISPENSER PAN SENSOR W AUTO SHUT OFF FOR D 6. NONE 469 <br />DISPENSER + AUDIBLE AND VISUAL ALARMS <br />IX. OWNER/OPERATOR SIGNATURE <br />467 <br />I ea* that the mfonpa6on providedherem u true <br />NAME OF OWNER/OPRATOR (pnnt) <br />10/2N /0 <br />MANAGER <br />UPCF (1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.