Laserfiche WebLink
0 STATE OF CALIFORNIA • <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br />MARK ONLY ❑ I NEW PERMIT ❑ <br />3 RENEWAL PERMIT ❑ <br />5 CHANGE OF INFORMATION <br />❑ <br />7 PERMANENTLY CLOSED ON SITE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ <br />d AMENDED PERMIT ❑ <br />6 TEMPORARY TANK CLOSURE <br />❑ <br />8 TANK REMOVED <br />/ V 11 <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />Z(y p i-06 / <br />A L/or-- <br />❑ 3 FIBERGLASS <br />6 STEEL CLAD Wl FIBERGLASS REINFORCED PLASTIC <br />I TANK(1PSCRIPTION cnMPI PTF ALL ITEMS- SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I.D.# <br />❑ A OIL <br />❑ BO EMPTY <br />❑ 95 UNKNOWN <br />• <br />B. MANUFACTURED BY: 'Ic, <br />8 3 DIESEL ❑ 6 AVIATION GAS <br />4 GASAHOL ❑ T METHANOL <br />5 JET FUEL <br />99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED <br />C. DATE INSTALLED (MO/DAY/YEAR) <br />2 SINGLE WALL <br />0 <br />D. TANK CAPACITY IN GALLONS: <br />AIV2 DOUBLE WALL A U <br />II TAAIvpnkffcNTC wov of cIc TPMl <br />A 1 MOTOR VEHICLE FUEL <br />❑ 2 ETROLEUM <br />❑ 3 CHEMICAL PRODUCT <br />❑ A OIL <br />❑ BO EMPTY <br />❑ 95 UNKNOWN <br />B. <br />I PRODUCT <br />❑ 2 WASTE <br />C. 1aUNL U EI <br />❑ 1 PREMIUM <br />UNLEADED <br />❑ 2 LEADED <br />8 3 DIESEL ❑ 6 AVIATION GAS <br />4 GASAHOL ❑ T METHANOL <br />5 JET FUEL <br />99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED <br />go&n <br />2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />111 TAMIL PAI,ICTGIIPTKIN n1JCI[UnUVINMnYC9A P ANnn ANn AIIITHATAPPIIFSINROXDANDE <br />IV PIPINr INFORMATION CIRCI F A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />I DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />A. TYPE OF <br />SYSTEM <br />B. <br />2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />AIV2 DOUBLE WALL A U <br />F71 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />6 STEEL CLAD Wl FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />r77 ALUMINUM <br />❑ B 100% METHANOL COMPATIBLE W/FRP <br />(PNmaD/Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />A U 8 100% METHANOL COMPATIBLE W/FRP <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />EPDXY LINING <br />❑ 6 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />�3 <br />95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />MOMRORING ❑ 99 OTHER <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL 7 <br />YES— NO— <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />A FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br />IV PIPINr INFORMATION CIRCI F A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />p GY2 PRESSURE A U <br />3 GRAVITY <br />A U 99 OTHER <br />B. <br />CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />AIV2 DOUBLE WALL A U <br />3 LINED TRENCH <br />A U 96 UNKNOWN A U 99 OTHER <br />C. <br />MATERIAL AND <br />A U <br />1 BARE STEEL <br />A U 2 STAINLESS STEEL A U <br />3 POLYVINYL CHLORIDE (PVC) A U 4 FIBERGLASS PIPE <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U 6 CONCRETE A U <br />7 STEEL W/ COATING <br />A U 8 100% METHANOL COMPATIBLE W/FRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U 10 CATHODIC PROTECTION <br />A U 95 UNKNOWN <br />AOTHER <br />D. <br />LEAK DETECTION <br />❑ i AUTOMATIC LINE LEAK QETECTOR ❑ 2 LINE TIGHTNESS TESTING <br />MOMRORING ❑ 99 OTHER <br />V. TANK LEAK DETECTION <br />❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ A AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />❑ 6 TANK TESTING E�Y7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAYNR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑ NO C:]SUBSTANCE REMAINING <br />GALLONS <br />INERTMATERIAL? <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />(PRINTED A SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # I TANK # UD <br />STATE I.D.# = a <br />PERMITNUMBEfl PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />FORM B (7.91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FOROaMSM <br />