0 <br />Connector Elbows <br />A brass elbow fining which Is designed to connect two flexible pipe sections. <br />Typically used for sharp 90' piping turns. This fitting should be installed within <br />a containment sump. <br />Connector Fitting <br />A brass fitting designed to adapt one coupled flexible pipe section to another <br />coupled flexible pipe section. Typically used for long piping runs and installed <br />within an In-line Piping Sump, <br />Crossover Supports <br />Used to separate GeoFlex Pipe runs at all crossover intersections, providing <br />sufficient support to prevent the upper pipe from deforming the lower after <br />backfill. ' r <br />Connector Tees <br />Designed to connect three flexible pipe sections. Typically used for split <br />piping runs leading to remote dispensers and installed within an In-line Piping <br />Sump. <br />Connector Tubes <br />These lube assemblies interconnect two Test Boots inside the junction type <br />Dispenser Sumps. Used to route the GeoFlex I and 11 interstitial space of <br />one pipe section around the Junction Tee Fitting to the interstitial space of the <br />next pipe section. Used primarily in pressure piping systems. <br />Deep Dispenser Sumps <br />Deep containers for under dispenser containment. Used primarily for <br />pressure piping systems which are routed in series and require piping fall to <br />one or more containment sumps. They provide convenient access to, and <br />secondary containment of, the pipe connections. <br />Directional Elbows <br />Installed inside Tank Sumps and connected to either single or dual adapters, <br />providing a multi -directional transition for the flexible piping line. <br />Dual Adapters <br />A brass fitting designed to adapt one 2' line to two 1-1/2' flexible piping lines <br />and typically used for assembly of a dual outlet plumbing tree. In this <br />application the Directional Elbow Fittings are usually connected to provide <br />multi -directional routing. <br />Extension Cylinder <br />This coupling cylinder connects to the Coupling Machine to permit in -sump <br />coupling of the flexible piping. <br />Female Adapters <br />A brass -fitting designed to adapt from a coupled flexible pipe section to a 2' <br />pipe nipple or street elbow lining. Typically used to conned a 2' tank fitting or <br />a pumps plumbing tree to a flexible supply line inside the Tank Sump. <br />Flexible Entry Boots <br />These rubber compression type boots are installed into the wall of <br />containment sumps to seal all pipe and conduit entries. <br />GeoFlex Piping <br />A flexible underground piping used for use transmission of flammable and <br />other types of hazardous liquids in both pressure and suction type systems. <br />In-line Piping Sumps <br />In -Line Piping Sumps are used for long piping runs which require pipe <br />sections be Connected together. This sump provides surface access and <br />secondary containment for these plumbing connections. May also be used to <br />contain other piping components. <br />Jacket Cutter <br />This hand tool is used to strip a 2' length of the containment jacket from the <br />and of the GeoFlex Pipe section, so that the Pipe Coupling can be installed. <br />4 <br />Junction Tees <br />Installed in junction type Dispenser Sumps. Typically used in pressure piping <br />systems which are routed in series. This tee has two threaded openings for <br />coupling connections and one threaded opening for riser pipe connections. <br />LDS (Leak Detection System) <br />An electronic monitoring system that will detect the presence of hydrocarbon <br />or water within containment sumps. <br />Liquid Monitoring System <br />Used to continuously monitor the interstitial space of the Environ flexible <br />piping. <br />Male Adapters <br />A brass fitting designed to adapt from a coupled flexible pipe section to a 2 - <br />female threaded standard pipe fitting. Typically used to connect a 2' tank <br />fitting or a pumps plumbing tree to a flexible supply line inside the Tank <br />Sump. <br />Pipe Couplings <br />Designed specifically for GeoFlex Piping. They are internally expanded to <br />the ends of the flexible pipe section for plumbing attachments. <br />Product Offsets <br />Used with some model dispensers which require pipe entry locations <br />significantly off center. The offset fitting permits using standard dispenser <br />sumps to accommodate these applications. <br />Shallow Dispenser Sumps <br />Shallow containers for under dispenser containment. Recommended for all <br />suction type piping systems and pressure piping systems using the Liquid <br />Interstitial Monitoring System. They Provide convenient access to, and <br />secondary containment of, the pipe connections. <br />Stabilizer Bar <br />Used in sumps and pans to stabilize a shear valve, break -away valve or riser <br />pipe. <br />Swivel Wrench <br />This hex type wrench Is designed to secure and tighten the Pipe Couplings to <br />either the GeoFlex fittings or adapters. <br />Tank Sumps <br />Tank Sumps are used at the beginning of the GeoFlex Piping System . <br />Installed to the top of the lank, they provide surface access to a tank's <br />pump, fittings and other piping connections. They also serve as a means of <br />secondary containment and leak collection. <br />Terminating Elbows <br />Installed in terminating type Dispenser Sumps. Used in both pressure and <br />suction piping systems. This elbow fitting has one threaded opening for <br />coupling connections and one threaded opening for riser pipe cpnnections. <br />Test Boots <br />These rubber boots are used to provide a means of connecting the Test <br />Tubes and Connector Tubes to the GeoFlex I and 11 Piping interstitial space <br />for integrity testing and continuous monitoring. These boots are fitted with <br />two stainless band clamps for a liquid tight seal. <br />Test Caps <br />These threaded caps are fitted with a Teflon seal and have a 1/4" opening in <br />the end for attachment of an air gauge or valve stem. Used to air test <br />individual pipe sections. <br />Test Tubes <br />Connected to Test Boots which are installed at the beginning and end of a <br />GeoFlex I and Il line. Used to test or continuously monitor the interstitial space <br />of the entire piping line and used for both pressure and suction piping systems. <br />Lz <br />