Laserfiche WebLink
16. P Tanks subject to floamn. [Section 2635 (a) (7)] <br />A. Anchored by deadman or slab. <br />a, Anchors to be installed as specified by manufacturer. <br />_ C. Installation details provided on plans. <br />D. Calculations provided. <br />17. SPILL AND OVERFILL PREVENTION <br />Underground storage tank equipped with spill container and an overfill prevention system. (detail drawing of spili <br />containers)/piping sump(s) required, Including tank fill and all openings). <br />A. Spill container (Section 2635 (b) (1)]. <br />If made of metal, exterior wall protected from galvanic corrosion. <br />Capacity: (minimum of five gallons) <br />Equipped with a drain valve which allows drainage of spill into primary container. <br />C_ - Manufacturer: PCrT S +.,J. <br />B. Overfill prevention system does not allow for manual override and meets one of the following requirements: <br />f_-- (1) Alert transfer operator at 90% full by restricting the flow into the tank or triggering an audible <br />and visual alarm (Section 26350)(2)(A)l . <br />Manufacturer: EJ",,, to •-_},.:._; Model: <br />(2) Restrict delivery flow to the tank 30 minutes before overfill when tank is tilled at no more than <br />95% capacity and activates an audible alarm at least five minutes before overfill [Section 2635 <br />(b) (2) (B)]. <br />Manufacturer: Model: <br />(3) Provide positive shut off at no more than 95% capacity [Section 2635 (b) (2) (C)l. <br />Manufacturer- Model: , <br />(A) Provide positive shut-off of flow to the tank so that the fittings an top of the tank are not <br />exposed to the product overfilling [Section 2635 (b) (2) (D)1. <br />Manufacturer: �[f��-) , [' Y -('n -+r 1Cr�. Model • ill.° ll -{^'!on t UA /u q.. <br />10. PIPING INFORMATION <br />PIPING INFORMATION <br />TANK# <br />TANK# <br />TAN K# <br />TANK# <br />DISTANCE from1 <br />DISPENSER to TANK <br />S <br />7-S'_ <br />3s, ] <br />MANUFACTURER <br />•).r_cF- �.-,. ]1 - (` ^r�• <br />SYSTEM TYPE ' <br />(J (ZQp•q i„�e,` <br />CONSTRUCTION •' <br />��rg., I.,1C �• !/ll <br />MATERIAL ' <br />(-1�•��J ��. h�t1 ��7..i.�. <br />f ,•OWN <br />LEAK DETECTION SYSTEM <br />$CNSr41,1 I.+ <br />100% METHANOL COMPATIBILITY <br />YES NO <br />CORROSION PROTECTION <br />YES NO <br />• System Type; suction, pressure, and gravity <br />•• Construction: single -walled, double -walled, lined -trench, etc. <br />'•' Material Type; steel with cathodic protection, stainless-steel, fiberglass reinforced plastic. <br />