My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2660
>
2300 - Underground Storage Tank Program
>
PR0231652
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 3:40:18 PM
Creation date
11/5/2018 5:57:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231652
PE
2381
FACILITY_ID
FA0003696
FACILITY_NAME
CONTI TRUCKING INC
STREET_NUMBER
2660
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
952130488
APN
17910001
CURRENT_STATUS
02
SITE_LOCATION
2660 LOOMIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\2660\PR0231652\BILLING 1985 - 2002 .PDF
QuestysFileName
BILLING 1985 - 2002
QuestysRecordDate
7/26/2017 4:33:27 PM
QuestysRecordID
3529646
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 TANKS <br /> UNDERGROUND PIPING VL PIPING CONSTRUCTION(CMck aY thesappy) <br /> SYSTEM TYPE ❑ 1 PRESSURE ABOVEGROUND PIPING <br /> ❑ 2. SUCTION 3 GRAVITY ❑ <br /> CONSTRUCTION/ 111. SINGLE WALL 113. LINED TRENCH 1. PRESSURE ❑ 2. SUCTION <br /> MANUFACTURER 132, DOUBLE WILL ❑99. OTHER ❑ 1. SINGLE WALL ❑ 9. GRAVITY <br /> ❑95. UNKNOWN 1195.El 2 DOUBLE WALL UNKNOWN <br /> MANUFACTURER <br /> MANUFACTURER ❑99. OTHER <br /> ❑ 1.BARESTEEL ❑ e. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2, STAINLESS STEEL ❑ 1. BARESTEEL <br /> CORROSION ❑ T GALVANIZED STEEL ❑B. FRP COMPATIBLE W/100%METHANOL <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITHCONTENTS132 STAINLESS STEEL <br /> �95. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ ] GALVINIZEDSTEEL <br /> . FLEXIBL <br /> ❑ 9. FIBERGLASS ❑ 8E(HDPE) 099, OTHER 11 4, FIBERGLASS 118. FLEXIBLE(HDPE) 1199. OTHER <br /> ❑ 5. STEEL W/COATING ❑ 9. CATHODICPROTECTION ❑ 9. CATHODIC PROTECTION <br /> ' ❑ 5. STEEL W1 COATING VIL PIPING LEAK DETECR 5, STEEL a1 COATING - ❑95. UNKNOWN <br /> SINGLE WALL PIPING UNDERGROUND PIPING <br /> PRESSURIZED PIPING(CMck al/fhafappy): ABOVEGROUND PIPING <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3D GPH TEST WITH AUTO PUMP SHUT OFF FOR PRESSURIZED PIPING(Cheri aN thele SINGLE WALL PIPING <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION AUDIBLE ANO VISUAL ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TESTWITH AUTO PUMP SHUT OFF FOR LEAK, <br /> ALARMS <br /> 2MONTHLY 0.2 GPM TEST SYSTEM FAILURE.AND SYSTEM DISCONNECTION a AUDIBLE AND VISUALALARMS <br /> ❑ . ❑ 2. MONTHLY 02 GPH TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> CONVENTIONAL SUCTION SYSTEMS: ❑ 4. DAILY VISUAL CHECK <br /> DAILY <br /> UAL <br /> ❑ S(Cheek all hat <br /> 5.TEST(0I1 GPH) OF PUMPING SYSTEM eTRIENNIAL PIPING INTEGRITY ❑ <br /> CONVENTIONAL <br /> VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST VI GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOWGROUND PIPING): ❑ e TRIENNIAL INTEGRITY TEST IDA GPH) <br /> Cl T SELFMONITORING SAFE SUCTION SYSTEM'(NO VALVES IN BELOWGROVND PIPING): <br /> GRAVITY FLOW ❑ 7. SELF MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0,1 GPH) GRAVITY FLOW(Check ad Maf appy): <br /> luR0rrRTe-sTGB. DAILY VISUAL MONITORING <br /> SECONDARILY CONTAINED PIPING ❑ 9. BIENNIALINTEGRITYTEST(OAGPH) <br /> PRESSURIZED PIPING(Cheek all that appy): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND PRESSURIZED PIPING(Check ad that SECO <br /> appy).NOARILY CONTAINED PIPING <br /> (Check one) <br /> ❑ e.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS 10.CONTINUOUS TURBINE SUMP SENSOR'MTH AUDIBLE AND VISUAL ALARMS AND(Aleck ane) <br /> ❑ b.AUTO PUMP SHUT OFF FOR LEAKS.SYSTEM FAILURE AND SYSTEM ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> DISCONNECTION <br /> ❑ c NO AUTO PUMP SHUT OFF 13b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR 13.0 GPH TEST)NTH FLOW SHUT OFF OR IJ c. NO AUTO PUMP SHUT OFF <br /> RESTRICTION <br /> 12.ANNUAL INTEGRITY ❑ 11. AUTOMATIC LEAK DETECTOR <br /> INTEGRITYTEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: 1112 ANNUAL INTEGRITY TEST Al GPH) <br /> ❑ 13. CONTINUOUS SUMP SENSOR I AUDIBLE AND VISUAL ALARMS SUCTIOWGRAVITYSYSTEM: <br /> EMERGENCY GENERATORS ONLY(Check as Maf eppty) ❑ 13 CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL AIARMS <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTOPUMP SHUT OFF•AUDIBLE AND EMERGENCY GENERATORS ONLY(Check aY Maf appy) <br /> VISUAL ALARMS ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF 4 AUDIBLE AND VISUAL <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3-0 GPH TEST)WITHOUT FLOW SHUT OFF OR ALARMS <br /> RESTRICTION ❑ 18.AUTOMATIC LINE LEAK DEFECTOR SD GPH TEST) <br /> ❑ 18.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILYVISUALCHECK ❑ 18. ANNUAL INTEGRITY TEST IDA GPH) <br /> ❑ 1]. DAILY VISUAL CHECK <br /> VBL DISPENSERCONTAINMENT <br /> DISPENSER COertA1NMEjjj <br /> ECHANISM THAT SHUTS OFF SMEAR VALVE <br /> DATE INSTALLED UOUS DISPENSER PAN SENSOR♦AUDIBLE AND VISUAL ALARMS ❑ 4, DAILY VISUAL CHECK <br /> OUS DISPENSER PAN SENSOR HATH AUTO SHUT OFF FOR DISPENSER t AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> NONE <br /> I aeNry mal me Inlolma5one an,att rote tome beet f myMwvaaa9eXOWNER/OPERATOR SIGNATURE <br /> SIGNATURE OF OWNER/ <br /> DATE <br /> NAME OF OWNEWOPERATOR(Pont) <br /> TITLE OF OWMEWOPERATOq <br /> Permit Number(Far local uas any) PartnitA <br /> pprovea(FDrlogl uas onyJ <br /> Permit Ekpbaecn Dale(Fprbnl use pny) <br /> :3d- L a <br /> CUPAFORM(4/99) • • <br /> Forrnedy SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.