My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2660
>
2300 - Underground Storage Tank Program
>
PR0231652
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 3:47:17 PM
Creation date
11/5/2018 5:58:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231652
PE
2381
FACILITY_ID
FA0003696
FACILITY_NAME
CONTI TRUCKING INC
STREET_NUMBER
2660
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
952130488
APN
17910001
CURRENT_STATUS
02
SITE_LOCATION
2660 LOOMIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\2660\PR0231652\COMPLIANCE INFO 1992 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 1992 - 2007
QuestysRecordDate
7/26/2017 4:47:04 PM
QuestysRecordID
3529749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California State Water Resources Control Board (February 6, 1992) <br /> Horner creative Products, Inc. <br /> Horner Ezy-Chek II (Overfilled Test) <br /> UST TIGHTNESS TEST METHOD <br /> Threshold: 0. 05 gallon per hour (Po=99 . 95% ; PFa=0. 05%} <br /> Aonlicabilit : gasoline, diesel, aviation fuel, fuel oil n4 , or <br /> others ; <br /> Caoacity, the maximum UST capacity shall be 12 , 000 gallons ; <br /> the UST must be 100 percent full ; <br /> Waiting Time⢠minimum waiting time between delivery and test data <br /> collection shall be six (6) hours; <br /> minimum waiting time between "topping off" and test <br /> data collection shall be three (3} hours ; <br /> Test Period: the minimum data collection time shall be one hour <br /> and forty minutes (33 minutes monitor mode and 67 <br /> minutes test mode) ; <br /> leak rate calculated from data of last 67 minutes <br /> of test period; <br /> at the conclusion of the test mode, data must be <br /> checked for the manufacturer's stop test criteria, <br /> if data does not meet the criteria data collection <br /> shall continue; <br /> test data shall be acquired and recorded by a <br /> computer; <br /> Ground Water: ground water depth must be determined and if the <br /> water table is above the bottom of the UST, the <br /> test procedure compensating for its presence must <br /> be used. <br /> Calibration: load cell must be calibrated before each use. <br /> Horner Creative Products Evaluator: W. A. Kibbe & Associates <br /> 212 Morton Street <br /> Bay City, MI 48706 <br /> Tel : (517) 893-3360 State Review Completed: 11-21-90 <br /> 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.