My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2850
>
2300 - Underground Storage Tank Program
>
PR0231651
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2022 4:17:43 PM
Creation date
11/5/2018 6:11:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231651
PE
2381
FACILITY_ID
FA0003857
FACILITY_NAME
CONTECH CONSTRUCTION
STREET_NUMBER
2850
Direction
E
STREET_NAME
LOOMIS
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
17910003
CURRENT_STATUS
02
SITE_LOCATION
2850 E LOOMIS AVE
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\2850\PR0231651\BILLING 1985 - 1999.PDF
QuestysFileName
BILLING 1985 - 1999
QuestysRecordDate
7/26/2017 10:38:22 PM
QuestysRecordID
3531892
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
aTAT OF GALIFORN WATER RESOURCES CONTR oARD <br /> FORM `B': UNDERGROUND STORAGE TANK PRO RAMa <br /> TANK TANK PERMIT APPLICATION INFORMATION _ <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I FORMATION FOR EACH TANK. z <br /> I C7 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY C <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED[-/ <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: <br /> hVe FARM TANK-YES❑ NO ❑ W <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK IDA I B. MANUFACTURED BY: � <br /> C. YEAR INSTALLED �� D. TANK CAPACITY IN GALLONS: Q <br /> 11. TANK,,CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMVI <br /> C. ❑ 1 UNLEADED ❑ 2 LEADED DIESEL <br /> F-13 CHEMICAL PRODUCT F-14 OIL RODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN 0 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,LINTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.4 C.A.S,9, <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF I UBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM Dy SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEELPRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 UMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> [:] 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> F-] 1 RUBBER LINED ❑ 2 ALKYD LINING E:] 3 EPDXY LINING [::],4 'IENOLIC LINING <br /> C. INTERIOR <br /> LINING F-] 5 GLASS LINING F76 UNLINED 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100`}>,METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3>AYLWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A 7u)2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 05 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE EPP <br /> A U 9 GALVANIZED STEEL A An <br /> 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> $ S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> 0 P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VV VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑ YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED CINDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,1S TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> MI I I :Ll El 1 1 ( 15-1F9-M <br /> CURRENT LOCAL AGENCY FACILITY ID ,r� APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE v p. <br /> CHECK III PERMIT AMOUNT SURCHARGE AMT. FEE CODE ECEIPT N BY: <br /> RM s 6-29-66 THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FO R M `A',UNLESS A CURRENT FORMA' HAS BEEN FILED•"/ / <br /> ( 1 <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.