My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
245
>
2300 - Underground Storage Tank Program
>
PR0515804
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2022 2:18:40 PM
Creation date
11/5/2018 6:19:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0515804
PE
2332
FACILITY_ID
FA0010091
FACILITY_NAME
SPEEDEE OIL CHANGE & TUNE-UP-MTCA
STREET_NUMBER
245
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
21635016
CURRENT_STATUS
02
SITE_LOCATION
245 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\245\PR0515804\COMPLIANCE INFO 2000 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2011
QuestysRecordDate
10/6/2017 8:28:36 PM
QuestysRecordID
3670040
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.ora/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Inspection date: <br />Speedee Oil Change & Tune -Up <br />June 14, 2011 <br />Facility address: <br />UST S / <br />1000. <br />650. <br />500 . <br />245 W Louise Ave, Manteca CA <br />Procto&, <br />used oil <br />' 5w30 <br />� 5w20 <br />� <br />� <br />� <br />Facility conte&, This: RRPhone: //y/� <br />Adam Ballard Owner <br />280 - <br />120 - <br />75 <br />i <br />ATF <br />15W40 <br />ugh Mileage <br />Monitoring panel: <br />Piping system: <br />Overfill prevention: <br />Violations: <br />uctionGmvity <br />[]Pressurized []S ❑ <br />❑Mechanical <br />�0101-RDetect <br />[IM2-Rprev EIM3-Both <br />❑Audible/visual <br />Inspection type: <br />Designated operator: ICC exp. date: <br />❑ Routine ❑ Monitoring Certification ❑ Installation © Other <br />On site Service Technician's name: ICC exp. date: <br />Manufacturer's training: <br /># <br />Code Section <br />VIOONS <br />V <br />R <br />HSC=CA Health & Safe Code; CCR=CA Code4oflRegulations; V=Violation- RV=Repeat Violation <br />V <br />1 <br />HSC 25284 <br />No permit to operate <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test <br />2 <br />CCR 2637 <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test <br />3 <br />CCR 2711 b <br />Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank fore <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />5 <br />CCR 2632(b) <br />Monitoring Program(Monitoring & Response Plans is not current or approved by the EHD <br />6 <br />CCR 2712(i) <br />Monitoiing plan, response plan, and/or operating rmit and all conditions not onsite <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 34 (11111) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitonng records include: (1) date and time of <br />7 <br />CCR 2712(b) <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre-January1, 1984 not performed 1 <br />9 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including ills and overfills <br />10 <br />CCR 2632(c)(2) <br />Monitoring system is not present in <br />the interstitials ace of a double walled UST M1 <br />11 <br />CCR 2630(d) <br />UST monitoring equipment is not installed <br />or maintained to detect a leak at the earliest opportunity(an) <br />12 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br />containment <br />13 <br />CCR 2636(f)(1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (M1) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631 a <br />Primary Containment is not product tight <br />15 <br />HSC 25291 (a)(2) <br />Secondary containment for UST system is not tight <br />16 <br />CCR 2636(c)(1) <br />All releases in secondary pipingdo not flow to a collection sum <br />17 <br />CCR 2636(D(2) <br />Line leak detector(s) not installed or failed to detect a3 -gallon per hour leak at 10 psi M1) <br />18 <br />CCR 2635(b)(1) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (112) <br />to keep the spill container empty <br />19 <br />CCR 2635(b)(2) <br />Overfill prevention <br />system was overridden or failed to meet overfill requirements in this section (11112) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) M2) <br />21 <br />HSC 25291 a <br />Water in 20 containment of removed analyzed & property disposed of <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (Mt) <br />22 <br />CCR 2650 <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHD of change of designated operator within 30 days <br />23b <br />CCR 2715(b) <br />Design ted operator did ICC UST System Operator certification <br />EHD inspector: <br />Re ce <br />Title: <br />EHD 2M2- 2 REV 08/1 0 - Page 1 �� UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.