TMS-2000
<br /> o o U
<br /> W
<br /> U p N
<br /> 1—I p Cq
<br /> O00 > � Io
<br /> 0 o q
<br /> W � �
<br /> 3/4" 8"x 6"x 6"J-BOX V] o
<br /> SEALED ROBROY-"� / f (WALL MOUNTED) '•'� >; E" 9
<br /> FAX/MODEM JUNCTION BOX `� 61 TO
<br /> (OPTIONAL) MONITOR PANEL # J-60OW MYERS
<br /> HUB UPS POWER (3/4")
<br /> m a MN
<br /> a r.MOI no
<br /> ®K WATERPROOF �G` <1
<br /> 0 0 r a�F ®K 3M SEALING
<br /> PACK 5'-0" C LVpw
<br /> ®� REo T REg�'6 (3M SKOTCHLOK $3570) ex 4"x 2" J-SOX
<br /> �waa MOUNTED)
<br /> COIL UP SPARE CABLE b
<br /> MP-450 7H 12 SCREW TERMINAL 3 y
<br /> ®< (CONNECTION TO Co
<br /> LS-610 TANK PROBE HOUSEKEEPING) Q;cz o
<br /> F i F F F , " TANK NTERSTITIAL rn 6 a\
<br /> SEAL-OFF
<br /> ---TO CONSOLE 3/4 1" TO PIPING SUMP MQE-14
<br /> mo vAc ON TANK
<br /> 'lox,soxn 3/4° CONDUIT
<br /> io EAHTH WERot° RIGID CONDUIT T'
<br /> BEE rere w TO BUILDING 0 EXTERNAL
<br /> RY-eYz coxaAwtunmas 55 66 MANAGEMENT SYSTEM ANNUNCIATOR �
<br /> 6 3 3 4") FINISHED FLOOR :D
<br /> aS-ae5 iD RV e[RVMAL9
<br /> NOTE: p
<br /> Elan) 1) REFER TO CABLE SELECTION GUIDE1 6 TMS-2000 Configuration on Interior Wall
<br /> MY E°RrA T WTH WTNT IN INSTALLATION MANUAL LS-600 LD-BN J
<br /> aEZ NOTE ,> U y 9 PIPING SUMP 5 SCALE: No Scale
<br /> NpeOTRY`°"'
<br /> IYEE NOTE e)
<br /> i°"" 15 MP-450 Probe & Sensor Control Drawing (Inside Piping Sump)
<br /> Nw-N, aEOu 5 SCALE: No Scale O
<br /> 6FE lE D
<br /> O
<br /> ___-_-___--_ E_ +-5 (150.,, 5538
<br /> J—_ 81 J w z
<br /> MA SPPEA OIMFNSICNS: INpIE9[NN] ] [13].29]-- 1t 1591) O
<br /> fl _ PP:RNMW1CNS-A-.
<br /> yyL' I4� (123.a2J-- 5 A (1. Qgy gy � � -- (4)n%NnNc941 ~ O C�.DQ Q QQ
<br /> HOLESIxgcATCR ugx9 O O O a-
<br /> FIBERGLASS MOUNT FOR �NOTES - INTRINSIC SAFETY: 2:655 2.460 zass ROBROY J-606W JUNCTION BOX -1) INTRINSICALLY SAFE INPUT WIRING: WIRE AND INSTALL IN ACCORDANCE WITH ARTICLE Z Q � � Q
<br /> 504 OF NAIONAL ELECTRICAL CODE ANSI/NFPA 70. NON-INTRISICALLY SAFE WIRING O U U U
<br /> CANNOT BE RUN IN CONDUIT OR OPEN RACEWAYS TOGEHTHER WITH INTRINSICALLY SAFE o ULLJO _J LLJWIRING.2) WARNING: TO INSURE INTRINSIC SAFETY, A 12 AWG WIRE MUST BE CONNECTED TO EACHl,5 ca:z NH6 ° ir°x+ •xpT a,,u rza.5! Mxq TFq J/.•NP ��A U TERMINAL ON THE EARTH GROUND TERMINAL BLOCK. EACH WIRE MUST THEN BE CONNECTED °A E)+'N°"11i 00NO01�9"TnNB °x E°°Iv^lu+�°°"oul*nT(n�"° 1 BUTT! 10C* w Q W111TO THE SYSTEM EARTH GROUND. THE RESISTANCE BETWEEN THE EARTH GROUND TERMINAL ECUIV5A1baaTEeF�°TYII "6/4'NP1 °aa�" W Ln 5`
<br /> BLOCK AND AND EARTH GROUND SHALL BE LESS THAN 1 OHM, mYz000PRNRRaPnnxS Mazoo6 s F- LC)
<br /> z39 z A[5a.e,T , deT PSMAY OPR-S TOP VIEW a-
<br /> 3) THE FOLLOWING PART NUMBERS MAY BE USED: MODEL MP440, MP450, MP451, MP452, MP460, ^a �_ Q
<br /> I740z13z %, (NEW CONSTRUCTION) LiJ N
<br /> 5e98)
<br /> OR MP461. J U
<br /> 4) THE FOLLOWING PART NUMBERS MAY BE USED: MODEL ES825-200(F) OR MODEL ES820-100 Ili [556)) - ������ ❑
<br /> (IMO IND, PART NUMBER 148941 (ELS-1100). 6[
<br /> O
<br /> 5 MAY BE ANY PASSIVE, DRY CONTACT DEVICE. _,g[z,z, �_ QO���� aELEC
<br /> 6; THE FOLLOWING PART NUMBERS MAY BE USED: MODEL ES820-200 (IMO IND. P/N 148797 e e e e Y
<br /> (ECS-1100). J-Box Z
<br /> 7) DRY CONTACT SWITCH OUTPUT WIRING TO COMMON AND EITHER NORMALLY OPEN OR NORMALLY MO,E Q
<br /> 1.EN0.OSARe METAIYC,RATED OPTIONS NEMA 12,4 OR 4X
<br /> CLOSED FOR DESIRED SWITCH CONTACT. OUTPUT RATED AT 10 AMPS AT 120 VAC, 8 AMPS AT 240 VAC. (VOLTAGE MUST BE <120 VAC OR <240 VAC RESPECTIVELY) z8) NEC CLASS 2 CKTS DIMENSIONS: INCHES(MM) TRICAL SEAL—OFF FITTING zFINISHED GRADE(4) SCRM AND 3KNOCKOUTS FOR
<br /> 5 1/4 (133.4)__- COVERS INCLUDED (IPNEUMERCATOR PANEL TO JCI OR CSI HOUSEKEEPING BOX Sq. 7 2° NPT OR IT RTILENT
<br /> RELAYS CONTACT L WIRE /rwln+ aNNu"cIATOR.10
<br /> HI FUEL RED DUPLICATE LINE SEQUENCING IN HOUSEKEEPING BOX � METRID CONOmT RTngc OLO l �-------WATER BLUE 013/54 (5,09)
<br /> 4 LEAK GREEN (2) HOLES —I" GC CONDUIT TO BUILDING a-
<br /> N-1
<br /> /8 -
<br /> Pneumercator TMS-2000 ')
<br /> 5 BACK VIEW WITH BOX REMOVED
<br /> SCALE No Scale I OO (25.4)— o
<br /> �_5 2,/52 (I43.J)—� TYP. I — -
<br /> —5 5/8 (142.9)— O o .. . ..
<br /> K
<br /> , O
<br /> SPECIFICAN)NS•
<br /> 1. SUPPLY VOLTAGE: O o
<br /> CUSTOMER- MCI CONSOLETYPe TMS20003141 RA20OPM POWER MODULE (ASSEMBLY
<br /> C'JS(OMER PO p- VERSION English INCLUDED
<br /> INSTALLLOCATIIXJ- Mante ca,CA POAER SETTING- 121 NITN RA200 ANNUNCIATOR) iEvuw4ngl w,RLs Q
<br /> INPUT: 115/230VAC Q
<br /> OUTPUT: 20VAC
<br /> CUSTOM PRINTER HEADER RA200 ANNUNCIATOR
<br /> INPUT: 20VAC
<br /> Site10: (rue crosle SadalNum40 Unet MCI (20 Charact.lMine) 2. AUDIBLE: 107EBA O 5', S PROGRAMMABLE TONES.
<br /> Unitt 1 Una2 1 MaI!S. CA (0ty and Slate) 3. VISUAL• 15 CANDELA STROBE.
<br /> TANK
<br /> 4. OPERATING TEMPERATURE. , NE TO 4150F. JJ
<br /> INTERIOR
<br /> S. ENCLOSURE: NON—METALLIC, NEMA 4%.
<br /> PJVENTORYPROBES
<br /> Tank
<br /> Tank Actual Inald• Matrdallof Tank End OrI•n- Comp- Meundna 17 TMS-2000 Monitor and RA-200 Alarm Details
<br /> Y ManWAotunr Med•I Ca Bel Dlam•t•rconatrucdon Sha • • Laden altm•nt Contort• Leeatlon L•Oaden T oDl
<br /> t CSI 01MI 550G 48° Flber lass DN/T S here H6rlmnlal N6 Dieeel UST Man. 01*1a ',,_VSCALE: No Scale
<br /> SENSORS ULLAGESETTINO LEVELALARMSE M1 FINISHED GRADE 1. Wire conductors fro the Pneumercator to the Turbine shall be 7 pairs of
<br /> Me N Faun S•n•er Tank App114AtIon - 85°b FROBEI TTINGS Belden 8441, 22 gauge stranded, braid shielded w/drain wire, PVC jacketed.
<br /> Number
<br /> ID NO
<br /> Med• p rsaexaeal SP1 05% Hi hHi h over
<br /> 1 LS 510 a Leak 1 Nublewall WaTERSETTING SP2 90% Toet? wer ELECTRICAL CONDUIT 1 -6°
<br /> 2 LSBUOLDEN N6 Leak t Turbine 2• Ever SP3 50% 1 Lew under COAXIAL CABLE CONDUIT
<br /> EnabUAuto Print �_L 2'-0" 2. Wire conductors from the Pneumercator to the Hoffman Box Alarm Panel in the ELECTRICAL
<br /> 2'-s" MIN OR shelter shall be a six pair, 22 gauge solid, PVC jacketed, Belden 8743.
<br /> RELAY OUTPUTS ImTank L. Tut
<br /> FUEL LINES 6" BELOW FROST LINE DETAILS
<br /> s1 MinTaak H hL.Ya 5P 2 t6RApoL NI Tanks , 4'-0" 3. Wire conductors from the Pneumercator panel to the RA-200 exterior alarm
<br /> k2 Mat ian Hoc Lu SRI' mRA2M Hom TankCa 550 DATE:
<br /> %3 MwnTenk HISLara EP2 t6M01Aaems tam TestM6da Tune 4'-6" shall be 3 conductor, 22 gauge stranded, PVC jacketed, Belden 8443. 10/14/05
<br /> Ip4 Meniank L6wLmel SP 3 t6MCIAe6 Sslem TestUnSt 02 h GROUNDING RING
<br /> DESIGNED BY: JBS
<br /> ss MmnT.nk wala,Narm toMCIAIatms tam Mln%vnl nod 4. All wire connections below grade within the turbine junction box shall be the
<br /> #8 Main Tank LNk6umma Sens"ra zaA2 t°MCINartns lem Test Rat Month
<br /> $N Rath. Monty
<br /> DRY Co CT PUTS D omMN 1st Da two parts, Scotchcast 4 or Grabor 4. Please note; wiring splices will not be DRAFTED BY:
<br /> s, fromReretRutton-R52 Start Duradorre I2oaaM COOLING TOWER MAKEUP LINE permitted other than to attach to the monitoring Components within SCALE: CLD
<br /> #2 from Testewon-RS2 Duration 1h:
<br /> Leak Prmt Passafan the junction box. AS .NOTED
<br /> FIBER OPTIC CABLE
<br /> 5. Mount new Robroy J606A junction box per 2,3.17 and 2.3.18 of Specifications. dDe #' 3101-33M
<br /> r1 Q Burial Depths FILE NAME:
<br /> 18 Pneumercator TMS-2000 Programming Inputs 2V Piping Sump Detail (New Construction) 3101-33M.DWG
<br /> rJ SCALE: No Scale cJ SCALE: NO SCALE cj SCALE: NO SCALE SHEET:
<br /> 5 oF5
<br />
|